English
Related papers

Related papers: Beam Dynamics Studies at the PIP-II Injector Test …

200 papers

The Fermilab Main Injector accelerating cavities have sparking issues when they are run at voltages higher than those required by the PIP-II project. This is a problem Fermilab is working on as planning begins for the next upgrade to the…

Accelerator Physics · Physics 2025-08-06 Susanna Stevenson

Suppression of beam losses is essential for successful operation of high-intensity linac. Historically, the values of the field amplitudes and phases of the side-coupled, 805-MHz LANSCE linac modules are maintained using a well-known…

Accelerator Physics · Physics 2020-02-26 Y. K. Batygin , F. E. Shelley , H. A. Watkins

A single gap, 352 MHz superconducting reentrant cavity for 5-100 MeV beams has been designed and it is presently under construction. This development is being done in the framework of a 30 mA proton linac project for nuclear waste…

Accelerator Physics · Physics 2009-10-05 A. Facco , M. Pasini , V. Zviagintsev

The Fermilab Muon Campus will host the Muon g-2 experiment - a world class experiment dedicated to the search for signals of new physics. Strict demands are placed on beam diagnostics in order to ensure delivery of high quality beams to the…

Accelerator Physics · Physics 2017-09-19 D. Stratakis , B. Drendel , M. J. Syphers

The Proton Improvement Plan II (PIP-II) project is a vital upgrade to the Fermilab accelerator complex. The magnet pulse rate of the PIP-II Injection system requires an increase from the current rate of 15 Hz to 20 Hz as well as a roughly…

In view of a possible evolution of the CERN accelerator complex towards higher proton intensities, a 2.2 GeV H- linac with 4 MW beam power has been designed, for use in connection with an accumulator and compressor ring as proton driver of…

Accelerator Physics · Physics 2007-05-23 M. Vretenar

A novel, induction type linear accelerator, the Neutralized Drift Compression eXperiment (NDCX-II), is currently being commissioned at Berkeley Lab. This accelerator is designed to deliver intense (up to 3x1011 ions/pulse), 0.6 to ~600 ns…

Materials Science · Physics 2015-06-12 T. Schenkel , S. M. Lidia , C. D. Weis , W. L. Waldron , J. Schwartz , A. M. Minor , P. Hosemann , J. W. Kwan

Typical front-ends of modern light-ion high-intensity accelerators typically consist of an ion source, a Low Energy Beam Transport (LEBT), a Radiofrequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT), which is followed by the…

Accelerator Physics · Physics 2017-04-17 L. Prost , A. Shemyakin

In this note, we address the beam performance (particle content, rates) with emphasis on the momentum determination and particle identification methods for the new H2-VLE (Very Low Energy) beam line that will serve the double phase…

Instrumentation and Detectors · Physics 2016-08-04 Nikolaos Charitonidis , Ilias Efthymiopoulos , Yannis Karyotakis

Project X is a multi-megawatt proton facility being developed to support intensity frontier research in elementary particle physics, with possible applications to nuclear physics and nuclear energy research, at Fermilab. The centerpiece of…

Accelerator Physics · Physics 2012-08-29 S. Nagaitsev

Fermilab has been working with the international particle physics and nuclear physics communities to explore and develop research programs possible with a new high intensity proton source known as "Project-X". Project X will provide…

High Energy Physics - Experiment · Physics 2011-09-19 R. Tschirhart

A front-end readout system with a large dynamic range is required for the high-granularity crystal electromagnetic calorimeter (ECAL) at future Higgs factories. A new commercially available ASIC, MPT2321, which offers a significantly large…

Instrumentation and Detectors · Physics 2025-05-23 Baohua Qi , Yong Liu , Huangchao Shi , Danqi Wang , Zhiyu Zhao , Hongbo Zhu

Project-X is the proposed high intensity proton facility to be built at Fermilab, US. First stage of the Project-X consists of superconducting linac which will be operated in continuous wave (CW) mode to accelerate the beam from 2.5 MeV to…

Accelerator Physics · Physics 2012-03-08 A. Saini , K. Ranjan , N. Solyak , S. Mishra , V. Yakovlev

This study is focused on an investigation of the performance of the Short Strip module developed by the ATLAS Inner Tracker (ITk) strip collaboration using electron beams of energy 5.4 GeV and 5.8 GeV at the DESY-II Testbeam Facility. The…

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the…

Accelerator Physics · Physics 2024-06-24 H. Piekarz , A. Romanov , R. Thurman-Keup , V. Shiltsev

The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…

Accelerator Physics · Physics 2015-11-09 R. Thurman-Keup , M. Alvarez , J. Fitzgerald , C. Lundberg , P. Prieto , M. Roberts , J. Zagel , W. Blokland

We report results of the beam commissioning and first operation of the 1.3 GHz superconducting RF electron linear accelerator at Fermilab Accelerator Science and Technology (FAST) facility. Construction of the linac was completed and the…

This paper presents the uTCA4.0-based BPM electronics for PIP-II, featuring four 250 MSPS ADCs and a Xilinx UltraScale+ MPSoC FPGA with 10 GbE uplink. Design elements include signal conditioning, clock, and thermal management. The FPGA…

Accelerator Physics · Physics 2025-09-22 Shengli Liu , Nathan Eddy , A. Semenov , Brian Fellenz

The Fermilab Linac experiences longitudinal beam phase drift, leading to increased particle loss, conventionally corrected through labor-intensive manual RF adjustments. This project explores machine learning-based automation for drift…

Accelerator Physics · Physics 2025-11-25 R. R. Chichili , J. A. Sulskis , R. Sharankova , B. Vamanan , S. Ravi

In preparation for PIP-II, there has been interest in running the Fermilab Booster at a higher current more indicative of the PIP-II era operation. In July 2023, an experiment was performed to study collective instabilities over the…

Accelerator Physics · Physics 2024-06-24 M. Balcewicz , J. Eldred