Related papers: Undetectable GPS-Spoofing Attack on Time Series Ph…
The increasing use of renewable generation, power electronic devices, and nonlinear loads in power systems brings more severe interharmonic tones to the measurand, which can increase estimation errors of P-class PMUs, cause misoperation of…
Malware is constantly evolving. Although existing countermeasures have success in malware detection, corresponding counter-countermeasures are always emerging. In this study, a counter-countermeasure that avoids network-based detection…
The phasor measurement unit (PMU) placement problem is revisited by taking into account a stronger characterization of the electrical connectedness between various buses in the grid. To facilitate this study, the placement problem is…
In this paper, we focus on the localization of a passive source from time difference of arrival (TDOA) measurements. TDOA values are computed with respect to pairs of fixed sensors that are required to be accurately time-synchronized. This…
Fault injection attacks induce hardware failures in circuits and exploit these faults to compromise the security of the system. It has been demonstrated that FIAs can bypass system security mechanisms, cause faulty outputs, and gain access…
Intelligent attackers can suitably tamper sensor/actuator data at various Smart grid surfaces causing intentional power oscillations, which if left undetected, can lead to voltage disruptions. We develop a novel combination of formal…
We address the problem of constructing false data injection (FDI) attacks that can bypass the bad data detector (BDD) of a power grid. The attacker is assumed to have access to only power flow measurement data traces (collected over a…
In this paper a new class of cyber attacks against state estimation in the electric power grid is considered. This class of attacks is named false data injection attacks. We show that with the knowledge of the system configuration an…
Sensors called phasor measurement units (PMUs) are used to monitor the electric power network. The power domination problem seeks to minimize the number of PMUs needed to monitor the network. We extend the power domination problem and…
Peaks and troughs in the subsynchronous impedance spectrum of a distribution feeder may be a useful indication of oscillation risk, or more importantly lack of oscillation risk, if inverter-based resource (IBR) deployments are increased on…
This paper presents an adaptive Distribution System State Estimation (DSSE) which relies on a Cloud-based IoT paradigm. The methodology is adaptive in terms of the rate of execution of the estimation process which varies depending on the…
With increasingly sophisticated cyber-adversaries able to access a wider repertoire of mechanisms to implant malware such as ransomware, CPU/GPU keyloggers, and stealthy kernel rootkits, there is an urgent need for techniques to detect and…
The false data injection (FDI) attack cannot be detected by the traditional anomaly detection techniques used in the energy system state estimators. In this paper, we demonstrate how FDI attacks can be constructed blindly, i.e., without…
This paper presents the design and the implementation of a servo-clock (SC) for low-cost Phasor Measurement Units (PMUs). The SC relies on a classic Proportional Integral (PI) controller, which has been properly tuned to minimize the…
The paper describes a distributed under-frequency load shedding and load restoration scheme, that exploits frequency and Rate-of-Change-of-Frequency (ROCOF) measurements produced by Phasor Measurement Units (PMUs) as detectors of a large…
As the worlds predominant navigation system GPS is critical to modern life, finding applications in diverse areas like information security, healthcare, marketing, and power and water grid management. Unfortunately this diversification has…
This paper presents a hybrid data-driven physics model-based framework for real time monitoring in smart grids. As the power grid transitions to the use of smart grid technology, it's real time monitoring becomes more vulnerable to cyber…
The most commonly used weighted least square state estimator in power industry is nonlinear and formulated by using conventional measurements such as line flow and injection measurements. PMUs (Phasor Measurement Units) are gradually adding…
With the continued deployment of synchronized Phasor Measurement Units (PMUs), high sample rate data are rapidly increasing the real time observability of power systems. Prior research has shown that the statistics of these data can provide…
This paper introduces an algorithm able to detect and localize the occurrance of a fault in an Active Distribution Network, using the measurements collected by Phasor Measurement Units (PMUs). First, a basic algorithm that works under the…