The Large Electron Multipliers (LEMs) are key components of double phase liquid argon TPCs. The drifting charges after being extracted from the liquid are amplified in the LEM positioned half a centimeter above the liquid in pure argon…

Instrumentation and Detectors · Physics 2015-06-23 C. Cantini , L. Epprecht , A. Gendotti , S. Horikawa , L. Periale , S. Murphy , G. Natterer , C. Regenfus , F. Resnati , F. Sergiampietri , A. Rubbia , T. Viant , S. Wu

T0 detector, based on Multi-gap Resistive Plate Chambers (MRPC) technology, is one of the key components in the External Target Experiment. Through precision measurements of the MRPC signals, timing of the beam impact on target can be…

Instrumentation and Detectors · Physics 2019-09-25 Peipei Deng , Lei Zhao , Jiaming Lu , Pinzheng Xia , Jinxin Liu , Min Li , Shubin Liu , Qi An

A large (240 cm $\times$ 120 cm $\times$ 0.2 cm) oil-free High Pressure Laminate (HPL), commonly referred as "bakelite", Resistive Plate Chamber (RPC) has been developed at VECC-Kolkata using locally available P-302 OLTC grade HPL. The…

Instrumentation and Detectors · Physics 2016-05-25 Rajesh Ganai , Arindam Roy , Kshitij Agarwal , Zubayer Ahammed , Subikash Choudhury , Subhasis Chattopadhyay

Multi-gap Resistive Plate Chambers (MRPCs) with multi-strip readout are considered to be the optimal detector candidate for the Time-of-Flight (ToF) wall in the Compressed Baryonic Matter (CBM) experiment. In the R&D phase MRPCs with…

Instrumentation and Detectors · Physics 2016-11-23 I. Deppner , N. Herrmann , J. Frühauf , M. Kiš , P. Lyu , P. -A. Loizeau , L. Shi , C. Simon , Y. Wang , B. Xie

We present a study of two di fferent sets of Micro-Channel Plates used for time and space resolved single particle detection. We investigate the eff ects of the gold coating and that of introducing an interplate voltage between the…

Instrumentation and Detectors · Physics 2013-03-04 Lynn Hoendervanger , David Clément , Alain Aspect , Christoph I Westbrook , Danielle Dowek , Yan PICARD , Denis Boiron

A silicon 3D detector with a single cell of 50x50 um2 was produced and evaluated for timing applications. The measurements of time resolution were performed for 90Sr electrons with dedicated electronics used also for determining time…

Instrumentation and Detectors · Physics 2019-06-26 G. Kramberger , V. Cindro , D. Flores , S. Hidalgo , B. Hiti , M. Manna , I. Mandić , M. Mikuž , D. Quirion , G. Pellegrini , M. Zavrtanik

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

Development of readout electronics for Time Projection Chamber for a Linear Collider is ongoing under stringent requirements on high channel density, lowest possible power consumption and small material budget. In the studied TPC readout…

Instrumentation and Detectors · Physics 2009-02-02 Alexander Kaukher

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive…

The ALICE Muon IDentifier is composed of 72 single-gap bakelite Resistive Plate Chambers, which have been operational since 2009 in maxi-avalanche mode (discrimination threshold:7 mV without amplification) with a…

Instrumentation and Detectors · Physics 2024-03-21 Alessandro Ferretti

An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas…

Large dynamic range room temperature photon number resolving (PNR) detectors can be very useful for measuring very low light intensities and for analyzing multiphoton quantum states. In this paper we present a PNR detector based on the…

Quantum Physics · Physics 2015-05-18 Enrico Pomarico , Bruno Sanguinetti , Rob Thew , Hugo Zbinden

Two cylindrical forward TPC detectors are described which were constructed to extend the phase space coverage of the STAR experiment to the region 2.5 < |\eta| < 4.0. For optimal use of the available space and in order to cope with the high…

The ALICE experiment at the Large Hadron Collider (LHC) proposes major detector upgrades to fully exploit the increase of the luminosity of the LHC in RUN~3 and to extend the physics reach for rare probes at low transverse momentum. The…

Instrumentation and Detectors · Physics 2019-08-13 Taku Gunji

A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, which has a sensitive area of 80 mm$\times$80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and…

Instrumentation and Detectors · Physics 2015-06-16 Shu-Wen Tang , Peng Ma , Li-Min Duan , Zhi-Yu Sun , Chen-Gui Lu , He-Run Yang , Rong-Jiang Hu , Wen-Xue Huang , Hu-Shan Xu

The ATLAS Muon Spectrometer is undergoing a major upgrade for the High-Luminosity LHC (HL-LHC), including the addition of three new thin-gap Resistive Plate Chamber (RPC) layers in the inner barrel region. These RPCs have 1 mm gas gaps…

Instrumentation and Detectors · Physics 2025-01-10 F. Fallavollita , O. Kortner , H. Kroha , P. Maly , G. Proto , D. Soyk , E. Voevodina , J. Zimmermann

A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural…

The increasing complexity of the recent photonic experiments challenges developing efficient multi-channel coincidence counting systems with high-level functionality. Here, we report a coincidence unit able to count detection events ranging…

Optics · Physics 2024-02-29 Josef Hloušek , Jan Grygar , Michal Dudka , Miroslav Ježek

The design, calibration, and performance of the first radial drift Time Projection Chamber (TPC) are presented. The TPC was built and installed at the CERES/NA45 experiment at the CERN SPS in the late nineties, with the objective to improve…

Nuclear Experiment · Physics 2012-08-27 The CERES Collaboration

The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the…