English
Related papers

Related papers: Improving count rate capability of timing RPCs by …

200 papers

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

Instrumentation and Detectors · Physics 2016-08-03 G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , R. Iuppa , B. Liberti , L. Paolozzi , E. Pastori , R. Santonico , M. Toppi

A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…

Instrumentation and Detectors · Physics 2009-11-07 A. Blanco , R. Ferreira-Marques , Ch. Finck , P. Fonte , A. Gobbi , A. Policarpo , M. Rozas

A Multi-gap Resistive Plate Chamber (MRPC) equipped with heaters to improve the counting rate capability was designed for the BM@N experiment in Dubna. The measurements were performed using a muon beam at IHEP U-70 accelerator in Protvino.…

Instrumentation and Detectors · Physics 2018-12-26 N. A. Kuzmin , E. A. Ladygin , V. P. Ladygin , Yu. P. Petukhov , S. Ya. Sychkov , A. A. Semak , M. N. Ukhanov , E. A. Usenko

The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps sigma for minimum ionising particles. Applications to HEP experiments have already taken place…

Instrumentation and Detectors · Physics 2009-11-07 A. Blanco , P. Fonte , L. Lopes , A. Mangiarotti , R. Ferreira-Marques , A. Policarpo

An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both…

Instrumentation and Detectors · Physics 2023-05-03 L. M. S. Margato , G. Canezin , A. Morozov , A. Blanco , J. Saraiva , L. Lopes , P. Fonte

We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements…

We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…

Usage of electrodes made of glass with low bulk resistivity seems to be a promising way to adapt the Resistive Plate Chambers (RPC) to the high-rate environment of the upcoming CBM experiment. A pilot four-gap RPC sample with electrodes…

The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…

Instrumentation and Detectors · Physics 2015-06-12 Y. Haddad , G. Grenier , I. Laktineh , N. Lumb , S. Cauwenbergh

For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…

This paper reports on detailed measurements of the performance of Resistive Plate Chambers in a proton beam with variable intensity. Short term effects, such as dead time, are studied using consecutive events. On larger time scales, for…

Instrumentation and Detectors · Physics 2009-06-25 B. Bilki , J. Butler , E. May , G. Mavromanolakis , E. Norbeck , J. Repond , D. Underwood , L. Xia , Q. Zhang

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…

Instrumentation and Detectors · Physics 2015-06-05 K. K. Meghna , A. Banerjee , S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , G. Das , C. Marick , S. Saha , Y. P. Viyogi

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…

The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of…

Instrumentation and Detectors · Physics 2016-09-21 F. Lagarde , M. Gouzevitch , I. Laktineh , V. Buridon , X. Chen , C. Combaret , A. Eynard , L. Germani , G. Grenier , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeuraa , Y. Wang , A. Gongab , N. Moreau , C. de la Taille , F. Dulucqac , A. Cimmino , S. Crucy , A. Fagot , M. Gul , A. A. O. Rios , M. Tytgat , N. Zaganidisb , S. Aly , Y. Assran , A. Radi , A. Sayedc , G. Singhd , M. Abbrescia , G. Iaselli , M. Maggi , G. Pugliese , P. Verwilligene , W. Van Doninck , S. Colafranceschi , A. Sharmag , L. Benussi , S. Bianco , D. Piccolo , F. Primaverah , V. Bhatnagar , R. Kumari , A. Mehta , J. Singhi , A. Ahmad , W. Ahmed , H. M. I. Asghar , I. M. Awan , R. Hoorani , S. Muhammad , H. Shahzad , M. A. Shah , S. W. Cho , S. Y. Choi , B. Hong , M. H. Kang , K. S. Lee , J. H. Lim , S. K. Parkk , M. S. Kiml , S. Carpinteyro Bernardino , I. Pedraza , C. Uribe Estradam , S. Carrillo Moreno , F. Vazquez Valencian , L. M. Panto , S. Buontempo , N. Cavallo , M. Esposito , F. Fabozzi , G. Lanza , I. Orso , L. Lista , S. Meola , M. Merola , P. Paolucci , F. Thyssen , A. Braghieri , A. Magnani , P. Montagna , C. Riccardi , P. Salvini , I. Vai , P. Vituloq , Y. Ban , S. J. Qianr , M. Choi , Y. Choi , J. Goh , D. Kimt , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , S. Stoykova , G. Sultanov , M. Vutovau , A. Dimitrov , L. Litov , B. Pavlov , P. Petkovv , I. Bagaturia , D. Lomidzew , C. Avila , A. Cabrera , J. C. Sanabria , I. Crottyy , J. Vaitkusz

This paper reports on the performance of Resistive Plate Chambers (RPCs) as function of the gas flow rate through the chambers and of environmental conditions, such as atmospheric pressure, ambient temperature and air humidity. The chambers…

Instrumentation and Detectors · Physics 2010-05-07 Burak Bilki , John Butler , Ed May , Georgios Mavromanolakis , Edwin Norbeck , Jose Repond , David Underwood , Lei Xia , Qingmin Zhang

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

Instrumentation and Detectors · Physics 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…

Instrumentation and Detectors · Physics 2024-07-16 João Pedro de Carvalho Saraiva , Alberto Blanco Castro

A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…

Instrumentation and Detectors · Physics 2020-01-29 A. Rocchi , R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento
‹ Prev 1 2 3 10 Next ›