English
Related papers

Related papers: Simplified Efficiency Calibration Methods for Semi…

200 papers

Large, high-purity, germanium (HPGe) detectors are needed for neutrinoless double-beta decay and dark matter experiments. Currently, large (> 4 inches in diameter) HPGe crystals can be grown at the University of South Dakota (USD). We…

Instrumentation and Detectors · Physics 2019-03-27 X. -H. Meng , G. -J. Wang , M. -D. Wagner , H. Mei , W. -Z. Wei , J. Liu , G. Yang , D. -M. Mei

Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout…

Instrumentation and Detectors · Physics 2013-12-23 K. Abe , Y. Hayato , T. Iida , K. Iyogi , J. Kameda , Y. Kishimoto , Y. Koshio , Ll. Marti , M. Miura , S. Moriyama , M. Nakahata , Y. Nakano , S. Nakayama , Y. Obayashi , H. Sekiya , M. Shiozawa , Y. Suzuki , A. Takeda , Y. Takenaga , H. Tanaka , T. Tomura , K. Ueno , R. A. Wendell , T. Yokozawa , T. J. Irvine , H. Kaji , T. Kajita , K. Kaneyuki , K. P. Lee , Y. Nishimura , K. Okumura , T. McLachlan , L. Labarga , E. Kearns , J. L. Raaf , J. L. Stone , L. R. Sulak , S. Berkman , H. A. Tanaka , S. Tobayama , M. Goldhaber , K. Bays , G. Carminati , W. R. Kropp , S. Mine , A. Renshaw , M. B. Smy , H. W. Sobel , K. S. Ganezer , J. Hill , W. E. Keig , J. S. Jang , J. Y. Kim , I. T. Lim , N. Hong , T. Akiri , J. B. Albert , A. Himmel , K. Scholberg , C. W. Walter , T. Wongjirad , T. Ishizuka , S. Tasaka , J. G. Learned , S. Matsuno , S. N. Smith , T. Hasegawa , T. Ishida , T. Ishii , T. Kobayashi , T. Nakadaira , K. Nakamura , K. Nishikawa , Y. Oyama , K. Sakashita , T. Sekiguchi , T. Tsukamoto , A. T. Suzuki , Y. Takeuchi , K. Huang , K. Ieki , M. Ikeda , T. Kikawa , H. Kubo , A. Minamino , A. Murakami , T. Nakaya , M. Otani , K. Suzuki , S. Takahashi , Y. Fukuda , K. Choi , Y. Itow , G. Mitsuka , M. Miyake , P. Mijakowski , R. Tacik , J. Hignight , J. Imber , C. K. Jung , I. Taylor , C. Yanagisawa , Y. Idehara , H. Ishino , A. Kibayashi , T. Mori , M. Sakuda , R. Yamaguchi , T. Yano , Y. Kuno , S. B. Kim , B. S. Yang , H. Okazawa , Y. Choi , K. Nishijima , M. Koshiba , Y. Totsuka , M. Yokoyama , K. Martens , M. R. Vagins , J. F. Martin , P. de Perio , A. Konaka , M. J. Wilking , S. Chen , Y. Heng , H. Sui , Z. Yang , H. Zhang , Y. Zhenwei , K. Connolly , M. Dziomba , R. J. Wilkes

High Purity Germanium (HPGe) detectors have been golden standard for gamma spectrometry in Low level radioactive waste (LLW) analysis; however, their notable shortcoming is prolonged measurement durations for weak radioactive waste…

Instrumentation and Detectors · Physics 2025-08-05 Yanfeng Xie , Yiming Weng , Soo Hyun Byun

In many applications, such as the detection of ultra-high energy cosmic rays using the air fluorescence method, the number of photons incident on the detector must be known. This requires a precise knowledge of the absolute efficiency of…

Instrumentation and Detectors · Physics 2015-06-22 Carl Blaksley , Philippe Gorodetzky

High purity germanium (HPGe) detectors are ubiquitous in nuclear physics experiments and are also used in numerous low radioactive background detectors. The effect of the position of $^{60}$Co and $^{137}$Cs point sources on the shape of…

Nuclear Experiment · Physics 2015-05-13 L. T. Evans , K. Andre , R. De , R. Henning , E. D. Morgan

The true coincidence summing effect on the full-energy peak efficiency calibration of an unsuppressed clover HPGe detector has been studied. Standard multi-energetic and mono-energetic gamma-ray sources were used to determine the…

Instrumentation and Detectors · Physics 2023-09-06 Ashish Gupta , M. Shareef , Munmun Twisha , Saikat Bhattacharjee , A. Mukherjee

The performance and scalability of rare-event physics experiments depend on large-volume, detector-grade high-purity germanium (HPGe) crystals with precise control of impurity segregation during growth. We report a detailed study of…

Instrumentation and Detectors · Physics 2025-11-27 S. Chhetri , D. -M. Mei , S. Bhattarai , N. Budhathoki , A. Warren , K. -M. Dong , S. A. Panamaldeniya , A. Prem

A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is…

Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the…

Instrumentation and Detectors · Physics 2023-03-07 Mayank Goswami , Kajal Kumari

$P$-type high-purity germanium (HPGe) detectors are widely used across many scientific domains, and current data analysis methods have served well in many use cases. However, applications like low-background experiments that search for rare…

Instrumentation and Detectors · Physics 2026-03-10 P. Zhang , W. Dai , Q. Zhang , F. Hagemann , O. Schulz , C. Alvarez-Garcia , L. Yang , Q. Yue , Z. Zeng , J. Cheng , H. Ma

The first operational prototype of a high-purity Germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic, multi-element sensor optimized for high-resolution…

Searches for new physics push experiments to look for increasingly rare interactions. As a result, detectors require increasing sensitivity and specificity, and materials must be screened for naturally occurring, background-producing…

Instrumentation and Detectors · Physics 2021-02-03 D. S. Leonard , I. S. Hahn , W. G. Kang , V. Kazalov , G. W. Kim , Y. D. Kim , E. K. Lee , M. H. Lee , S. Y. Park , E. Sala

We experimentally demonstrate a detection scheme suitable for state analysis of single optically trapped atoms in less than 1 {\mu}s with an overall detection efficiency {\eta} exceeding 98%. The method is based on hyperfine-state-selective…

This article proposes a new method to measure the proton detector efficiency for use in "beam" determinations of the free neutron lifetime. There is currently a 4{\sigma} disagreement between the "beam" and "storage" methods of measuring…

Instrumentation and Detectors · Physics 2024-10-07 Grant V. Riley , Nadia Fomin , Jaideep Taggart Singh , William Greene , Rebecca Godri , Evan Adamek , Eli Carter

A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte-Carlo simulations were used to build the…

Instrumentation and Detectors · Physics 2022-06-29 J. T. Matta , A. J. Rowe , M. P. Dion , M. J. Willis , A. D. Nicholson , D. E. Archer , H. H. Wightman

The integrated optical circuit is a promising architecture for the realization of complex quantum optical states and information networks. One element that is required for many of these applications is a high-efficiency photon detector…

We present two methods for determining the absolute detection efficiency of photon-counting detectors directly from their singles rates under illumination from a nonclassical light source. One method is based on a continuous variable…

Quantum Physics · Physics 2009-11-13 Michael Lindenthal , Johannes Kofler

The particle spectrometer SONIC for particle-$\gamma$ coincidence measurements was commissioned at the Institute for Nuclear Physics in Cologne, Germany. SONIC consists of up to 12 silicon $\mathit{\Delta}E$-$E$ telescopes with a total…

Instrumentation and Detectors · Physics 2017-10-23 S. G. Pickstone , M. Weinert , M. Färber , F. Heim , E. Hoemann , J. Mayer , M. Müscher , S. Prill , P. Scholz , M. Spieker , V. Vielmetter , J. Wilhelmy , A. Zilges

High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper are installed outside of the probe to shield gammas, outmost…

Characteristics improvement of photon/plasmon detectors have been the subject of several investigations in the area of plasmonic integrated circuits. Among different suggestions, Silicon-based Metal-Semiconductor-Metal (MSM) waveguides are…

Applied Physics · Physics 2019-01-31 Elahe Rastegar Pashaki , Hassan Kaatuzian , Abdolber Mallah Livani