English
Related papers

Related papers: Liquid-phase purification for multi-tonne xenon de…

200 papers

We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K…

Instrumentation and Detectors · Physics 2015-06-11 Elena Aprile , Ran Budnik , Bin Choi , Hugo Contreras , Karl Giboni , Luke Goetzke , Rafael Lang , Kyungeun Lim , Antonio melgarejo , Petr Shagin

The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium…

We present a measurement of the extraction efficiency of quasi-free electrons from the liquid into the gas phase in a two-phase xenon time-projection chamber. The measurements span a range of electric fields from 2.4 to 7.1 kV/cm in the…

Instrumentation and Detectors · Physics 2018-02-14 B. N. V. Edwards , E. Bernard , E. M. Boulton , N. Destefano , M. Gai , M. Horn , N. Larsen , B. Tennyson , L. Tvrznikova , C. Wahl , D. N. McKinsey

There is a compelling physics case for a large, xenon-based underground detector devoted to dark matter and other rare-event searches. A two-phase time projection chamber as inner detector allows for a good energy resolution, a…

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller…

Instrumentation and Detectors · Physics 2014-10-27 J. Yoo , H. Cease , W. F. Jaskierny , D. Markley , R. B. Pahlka , D. Balakishiyeva , T. Saab , M. Filipenko

Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through…

Instrumentation and Detectors · Physics 2011-03-08 K. L. Giboni , E. Aprile , B. Choi , T. Haruyama , R. F. Lang , K. E. Lim , A. J. Melgarejo , G. Plante

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT…

Instrumentation and Detectors · Physics 2022-12-28 M. Murra , D. Schulte , C. Huhmann , C. Weinheimer

PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon handling system is designed to liquify and purify this large…

Instrumentation and Detectors · Physics 2021-08-11 Li Zhao , Xiangyi Cui , Wenbo Ma , Yingjie Fan , Karl Giboni , Tao Zhang , Jianglai Liu , Xiangdong Ji

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber…

Instrumentation and Detectors · Physics 2022-02-23 N. Ackerman , J. Albert , M. Auger , D. J. Auty , I. Badhrees , P. S. Barbeau , L. Bartoszek , E. Baussan , V. Belov , C. Benitez-Medina , T. Bhatta , M. Breidenbach , T. Brunner , G. F. Cao , W. R. Cen , C. Chambers , B. Cleveland , R. Conley , S. Cook , M. Coon , W. Craddock , A. Craycraft , W. Cree , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , C. G. Davis , J. Davis , S. Delaquis , A. Der Mesrobian-Kabakian , R. deVoe , T. Didberidze , J. Dilling , A. Dobi , A. G. Dolgolenko , M. J. Dolinski , M. Dunford , J. Echevers , L. Espic , W. Fairbank , D. Fairbank , J. Farine , W. Feldmeier , S. Feyzbakhsh , P. Fierlinger , K. Fouts , D. Franco , D. Freytag , D. Fudenberg , P. Gautam , G. Giroux , R. Gornea , K. Graham , G. Gratta , C. Hagemann , C. Hall , K. Hall , G. Haller , E. V. Hansen , C. Hargrove , R. Herbst , S. Herrin , J. Hodgson , M. Hughes , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , A. Johnson , T. N. Johnson , S. Johnston , A. Karelin , L. J. Kaufman , R. Killick , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , F. Leonard , F. LePort , G. S. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , D. Mackay , R. MacLellan , M. Marino , J. -M. Martin , Y. Martin , T. McElroy , K. McFarlane , T. Michel , B. Mong , D. C. Moore , K. Murray , R. Neilson , O. Njoya , O. Nusair , K. O'Sullivan , A. Odian , I. Ostrovskiy , C. Ouellet , A. Piepke , A. Pocar , C. Y. Prescott , K. Pushkin , F. Retiere , A. Rivas , A. L. Robinson , E. Rollin , P. C. Rowson , M. P. Rozo , J. Runge , J. J. Russell , S. Schmidt , A. Schubert , D. Sinclair , K. Skarpaas , S. Slutsky , E. Smith , A. K. Soma , V. Stekhanov , V. Strickland , M. Swift , M. Tarka , J. Todd , T. Tolba , D. Tosi , T. I. Totev , R. Tsang , K. Twelker , B. Veenstra , V. Veeraraghavan , J. -L. Vuilleumier , J. -M. Vuilleumier , M. Wagenpfeil , A. Waite , J. Walton , T. Walton , K. Wamba , J. Watkins , M. Weber , L. J. Wen , U. Wichoski , M. Wittgen , J. Wodin , J. Wood , G. Wrede , S. X. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Ya Zeldovich , T. Ziegler

The XMASS project is designed for multiple physics goals using highly-purified liquid xenon scintillator in an ultra-low radioactivity environment. As the first stage of the project, the detector with 835 kg of liquid xenon was constructed…

Instrumentation and Detectors · Physics 2019-08-13 Katsuki Hiraide

The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of…

Instrumentation and Detectors · Physics 2016-08-25 S. Stephenson , J. Haefner , Q. Lin , K. Ni , K. Pushkin , R. Raymond , M. Schubnell , N. Shutty , G. Tarlé , C. Weaverdyck , W. Lorenzon

We report on the development and performance of a high-sensitivity purity-analysis technique for gaseous xenon. The gas is sampled at macroscopic pressure from the system of interest using a UHV leak valve. The xenon present in the sample…

Instrumentation and Detectors · Physics 2011-05-09 D. S. Leonard , A. Dobi , C. Hall , L. Kaufman , T. Langford , S. Slutsky , Y. R. Yen

The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic…

As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon…

Instrumentation and Detectors · Physics 2020-01-29 L. Tvrznikova , E. P. Bernard , S. Kravitz , K. O'Sullivan , G. Richardson , Q. Riffard , W. L. Waldron , J. Watson , D. N. McKinsey

A high performance distillation system to remove krypton from xenon was constructed, and a purity level of Kr/Xe = $\sim 3 \times 10^{-12}$ was achieved. This development is crucial in facilitating high sensitivity low background…

A small-scale, two-phase (liquid/gas) xenon time projection chamber (Xurich II) was designed, constructed and is under operation at the University of Zurich. Its main purpose is to investigate the microphysics of particle interactions in…

Instrumentation and Methods for Astrophysics · Physics 2018-05-23 Laura Baudis , Yanina Biondi , Chiara Capelli , Michelle Galloway , Shingo Kazama , Alexander Kish , Payam Pakarha , Francesco Piastra , Julien Wulf

We report results from a 13-liter purified liquid argon test stand at Wellesley College. The system includes a single-pass liquid-phase purification column, a double-gridded purity monitor to assess the electron lifetime, and a slow control…

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. We describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects…

Instrumentation and Detectors · Physics 2025-11-14 Evan Angelico , Jacopo Dalmasson , Ralph DeVoe , Giorgio Gratta , Clarke A. Hardy , Brian Lenardo , Lin Si , Marie Vidal , Shuoxing Wu

XeBRA is a flexible cryogenic platform designed to perform research and development for liquid xenon detectors searching for rare events. Its extra-large outer cryostat makes it possible to install a wide variety of detector designs. We…

Possibility to use ultra pure liquid Xenon as a low energy solar neutrino detector by means of $\nu$+e scatterings is evaluated. A possible detector with 10 tons of fiducial volume will give $\sim$14 events for pp-neutrinos and $\sim$6…

High Energy Physics - Phenomenology · Physics 2017-08-23 Y. Suzuki
‹ Prev 1 2 3 10 Next ›