English
Related papers

Related papers: Numerical calculation of RPC time resolution

200 papers

This document presents an overview of the activities of Brazilian groups on gaseous detectors, with emphasis on resistive plate chambers (RPCs) for the CMS experiment at the CERN LHC and related applications. It summarises the design,…

A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution…

High Energy Physics - Experiment · Physics 2007-05-23 V. Ammosov , V. Gapienko , A. Semak , V. Senko , Yu. Sviridov , V. Zaets , E. Usenko

The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…

Instrumentation and Detectors · Physics 2015-06-12 Y. Haddad , G. Grenier , I. Laktineh , N. Lumb , S. Cauwenbergh

A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and…

Usage of electrodes made of glass with low bulk resistivity seems to be a promising way to adapt the Resistive Plate Chambers (RPC) to the high-rate environment of the upcoming CBM experiment. A pilot four-gap RPC sample with electrodes…

While in a triggered experiment the matching of the RPC transmission line impedance with the one of the front-end electronics is less critical, for a trigger-less data recording this becomes mandatory. As expected, impedance matching is not…

Instrumentation and Detectors · Physics 2017-08-10 D. Bartoş , M. Petriş , M. Petrovici , L. Rădulescu , V. Simion

A novel concept for position-sensitive thermal neutron detectors based on thin-gap Resistive Plate Chambers (RPC) lined with a neutron converter layer is presented and its feasibility is discussed. Several detector architectures…

Instrumentation and Detectors · Physics 2018-08-29 L. M. S. Margato , A. Morozov

In this work we explore readout architectures for the simultaneous high-resolution timing and bidimensional tracking of charged particles with Resistive Plate Chambers (TOF-tracker) and for the accurate detection of gamma rays for PET…

The 50~kton Iron Calorimeter (ICAL) detector at the underground India based Neutrino Observatory (INO) will make measurements on atmospheric neutrinos. Muons produced in charged current (CC) interactions of muon neutrinos with the iron are…

Instrumentation and Detectors · Physics 2014-10-22 N. Dash , V. M. Datar , G. Majumder

A Resistive Plate Chamber using Diamond-Like Carbon electrodes (DLC-RPC) has been developed as a background tagging detector in the MEG$~$II experiment. The DLC-RPC is planned to be installed in a high-intensity and low-momentum muon beam.…

Instrumentation and Detectors · Physics 2025-06-13 Masato Takahashi , Sei Ban , Weiyuan Li , Atsuhiko Ochi , Wataru Ootani , Atsushi Oya , Hiromu Suzuki , Kensuke Yamamoto

The STAR Time Projection Chamber (TPC) is used to record collisions at the Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a suite of detectors that surrounds the interaction vertex. The TPC provides complete…

Time projection chambers (TPCs) have found a wide range of applications in particle physics, nuclear physics, and homeland security. For TPCs with high-resolution readout, the readout electronics often dominate the price of the final…

Instrumentation and Detectors · Physics 2016-11-17 S. J. Ross , M. T. Hedges , I. Jaegle , M. D. Rosen , I. S. Seong , T. N. Thorpe , S. E. Vahsen , J. Yamaoka

In this paper we would like to present a few characteristics of the Resistive Plate Chambers (RPC) made of a particular grade of bakelite paper laminates (P-120, NEMA LI-1989 Grade XXX), produced and commercially available in India. This…

Instrumentation and Detectors · Physics 2010-11-02 S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , S. Saha , Y. P. Viyogi

A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100…

Instrumentation and Detectors · Physics 2008-11-26 K. Boudjemline , M. S. Dixit , J. -P. Martin , K. Sachs

The India-based Neutrino Observatory (INO) collaboration is planning to build a massive 50kton magnetised Iron Calorimeter (ICAL) detector, to study atmospheric neutrinos and to make precision measurements of the parameters related to…

Instrumentation and Detectors · Physics 2019-08-13 Satyanarayana Bheesette

The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium…

Resistive Plate Chamber detectors are largely used in current High Energy Physics experiments, typically operated in avalanche mode with large fractions of Tetrafluoroethane (C2H2F4), a gas recently banned by the European Union due to its…

Instrumentation and Detectors · Physics 2024-10-16 Luca Quaglia

A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an…

Instrumentation and Detectors · Physics 2018-07-16 M. M. Aggarwal , Z. Ahammed , S. Aiola , J. Alme , T. Alt , W. Amend , A. Andronic , V. Anguelov , H. Appelshäuser , M. Arslandok , R. Averbeck , M. Ball , G. G. Barnaföldi , E. Bartsch , R. Bellwied , G. Bencedi , M. Berger , N. Bialas , P. Bialas , L. Bianchi , S. Biswas , L. Boldizsár , L. Bratrud , P. Braun-Munzinger , M. Bregant , C. L. Britton , E. J. Brucken , H. Caines , A. J. Castro , S. Chattopadhyay , P. Christiansen , L. G. Clonts , T. M. Cormier , S. Das , S. Dash , A. Deisting , S. Dittrich , A. K. Dubey , R. Ehlers , M. Engel , F. Erhardt , N. B. Ezell , L. Fabbietti , U. Frankenfeld , J. J. Gaardhøje , C. Garabatos , P. Gasik , Á. Gera , P. Ghosh , S. K. Ghosh , P. Glässel , O. Grachov , A. Grein , T. Gunji , H. Hamagaki , G. Hamar , J. W. Harris , P. Hauer , J. Hehner , E. Hellbär , H. Helstrup , T. E. Hilden , B. Hohlweger , M. Ivanov , M. Jung , D. Just , E. Kangasaho , R. Keidel , B. Ketzer , S. A. Khan , S. Kirsch , T. Klemenz , S. Klewin , A. G. Knospe , M. Kowalski , L. Kumar , R. Lang , R. Langoy , L. Lautner , F. Liebske , J. Lien , C. Lippmann , H. M. Ljunggren , W. J. Llope , S. Mahmood , T. Mahmoud , R. Majka , P. Malzacher , A. Marín , C. Markert , S. Masciocchi , A. Mathis , A. Matyja , M. Meres , D. L. Mihaylov , D. Miskowiec , J. Mitra , T. Mittelstaedt , T. Morhardt , J. Mulligan , R. H. Munzer , K. Münning , M. G. Munhoz , S. Muhuri , H. Murakami , B. K. Nandi , H. Natal da Luz , C. Nattrass , T. K. Nayak , R. A. Negrao De Oliveira , M. Nicassio , B. S. Nielsen , L. Oláh , A. Oskarsson , J. Otwinowski , K. Oyama , G. Paić , R. N. Patra , V. Peskov , M. Pikna , L. Pinsky , M. Planinic , M. G. Poghosyan , N. Poljak , F. Pompei , S. K. Prasad , C. A. Pruneau , J. Putschke , S. Raha , J. Rak , J. Rasson , V. Ratza , K. F. Read , A. Rehman , R. Renfordt , T. Richert , K. Røed , D. Röhrich , T. Rudzki , R. Sahoo , S. Sahoo , P. K. Sahu , J. Saini , B. Schaefer , J. Schambach , S. Scheid , C. Schmidt , H. R. Schmidt , N. V Schmidt , H. Schulte , K. Schweda , I. Selyuzhenkov , N. Sharma , D. Silvermyr , R. N. Singaraju , B. Sitar , N. Smirnov , S. P. Sorensen , F. Sozzi , J. Stachel , E. Stenlund , P. Strmen , I. Szarka , G. Tambave , K. Terasaki , A. Timmins , K. Ullaland , A. Utrobicic , D. Varga , R. Varma , A. Velure , V. Vislavicius , S. Voloshin , B. Voss , D. Vranic , J. Wiechula , S. Winkler , J. Wikne , B. Windelband , C. Zhao

Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low…

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC…

‹ Prev 1 3 4 5 6 7 10 Next ›