Related papers: Numerical calculation of RPC time resolution
Resistive Plate Chamber (RPC) is a type of gaseous detector having excellent time and position resolutions. VECC is involved in the R\&D of indigenously developed bakelite RPCs. The largest size of bakelite RPC developed in India is 100 cm…
We present here detailed derivations of mathematical expressions for the accuracy in the arrival direction of particles estimated using a set of stacked resistive plate chambers (RPCs). The expressions are validated against experimental…
A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…
For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS…
Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in high energy physics experiments, operating with a gas mixture primarily containing Tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$), commonly known as R-134a, which has a global…
Keeping in mind the requirements of high rate capable, cost effective, large area detectors to be used in future high energy physics experiments, commercially available bakelite plates having moderate bulk resistivity are used to build an…
A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE…
The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were…
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas…
Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs (5x5 and 10x10cm2) having rate capabilities of up to…
Numerical calculations have been performed to understand the reason for the observed non-uniform response of a Resistive Plate Chamber (RPC) in a few critical regions such as near edge spacers and corners of the device. In this context, the…
A numerical model based on Finite Element Method (FEM) has been developed to simulate the electrical properties of RPC utilizing the law of current conservation. It has been used to systematically investigate the effect of the electrical as…
A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…
A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…
The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data…
A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The…
This work reports a cost-effective, multi-parameter readout and data-acquisition system for a muon scattering tomography system based on Resistive Plate Chambers (RPCs). Initial test measurements with a prototype Resistive Plate Chamber…