Related papers: An optical transition-edge sensor with high energy…
The current and future cosmic microwave background (CMB) experiments fielding kilo-pixel arrays of transition-edge sensor (TES) bolometers require accurate and robust gain calibration methods. We simplify and refactor the standard TES model…
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of…
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375…
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final…
The tunnel junction between tip and sample in a scanning tunneling microscope is an ideal platform to access the local density of states in the sample through the differential conductance. We show that the energy resolution that can be…
Transient field-resolved spectroscopy enables studies of ultrafast dynamics in molecules, nanostructures, or solids with sub-cycle resolution, but previous work has so far concentrated on extracting the dielectric response at frequencies…
Non-line-of-sight (NLOS) imaging enables monitoring around corners and is promising for diverse applications. The resolution of transient NLOS imaging is limited to a centimeter scale, mainly by the temporal resolution of the detectors.…
Relative cross sections for the valence shell photoionisation (PI) of $\rm ^2S$ ground level and $\rm ^2D$ metastable Ca$^{+}$ ions were measured with high energy resolution by using the ion-photon merged-beams technique at the Advanced…
Here we report on a novel High Harmonic Generation (HHG) light source designed for space charge free ultrafast photoelectron spectroscopy (PES) on solids. The ultimate overall energy resolution achieved on a polycrystalline Au sample is ~22…
The Simons Observatory (SO) will perform ground-based observations of the cosmic microwave background (CMB) with several small and large aperture telescopes, each outfitted with thousands to tens of thousands of superconducting aluminum…
We report on the detection of single photons with {\lambda} = 8 {\mu}m using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 {\mu}m^3 fabricated on a silicon…
We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the…
A whole class of two-color experiments involves intense, short Terahertz radiation pulses. A fast detector that is sensitive and able to resolve both near-infrared and Terahertz pulses at the same time is highly desirable. Here we present…
Electroplated Bismuth (Bi) is commonly used in Transition-Edge Sensors (TESs) for X-rays because of its high stopping power and low heat capacity. Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically…
The primary challenge in silicon photonics is achieving efficient luminescence in the communication band, crucial for its large-scale application. Despite significant efforts, silicon light sources still suffer from low efficiency and…
At low temperatures, < 200 mK, the thermal flux through low-dimensional amorphous dielectric bars, < 2 $\mu$m wide and 200 nm thick, is transported by a small number of low-order elastic modes. For long bars, L > 400 $\mu$m, it is known…
Transverse energy ($E_T$) has been measured with both of it's components, namely hadronic ($E_T^{had}$) and electromagnetic ($E_T^{em}$) at mid-rapidity, for 62.4 GeV Au+Au collisions by the STAR experiment. In the common phase space of TPC…
The increasing concentration of greenhouse gases, notably CH4 and CO2, has fueled global temperature increases, intensifying concerns regarding the prevailing climate crisis. Effectively monitoring these gases demands a detector spanning…
We present methods to improve the energy resolution of single-channel, room-temperature Cadmium-Zinc-Telluride (CZT) detectors. A new preamplifier design enables the acquisition of the actual transient current from the crystals and…
Optical sensors offer precision, remote read-out, and immunity to electromagnetic interference but face adoption challenges due to complex and costly readout instrumentation, mostly based on high-resolution. This article challenges the…