Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/\Delta…
The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed…
The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2…
Transition-edge sensor X-ray microcalorimeters are usually calibrated empirically, as the most widely-used calibration metric, optimal filtered pulse height (OFPH), in general has an unknown dependance on photon energy, $E_{\gamma}$.…
We propose the use of transition-edge sensor (TES) single-photon detectors as a simultaneous target and sensor for direct dark matter searches, and report results from the first search of this kind. We perform a 489 h science run with a TES…
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different…
CMOS detectors offer many advantages over CCDs for optical and UV astronomical applications, especially in space where high radiation tolerance is required. However, astronomical instruments are most often designed for low light-level…
We are developing photon-counting cameras employing cryogenic arrays of energy-resolving TES (Transition Edge Sensor) pixels. These are being tested in ground-based instruments, but will have their greatest impact when employed on space…
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount…
Transition Edge Sensor (TES) bolometers are a well-established technology with a strong track record in experimental cosmology, making them ideal for current and future radio astronomy instruments. The Tomographic Ionized-carbon Mapping…
The 235U(n,f) cross section was measured in a wide energy range (25 meV - 170 keV) at the n_TOF facility at CERN, relative to 6Li(n,t) and 10B(n,alpha) standard reactions, with high resolution and accuracy, with a setup based on a stack of…
The stability of Al-Mn transition edge sensor (TES) bolometers is studied as we vary the engineered TES transition, heat capacity, and/or coupling between the heat capacity and TES. We present thermal structure measurements of each of the…
The measurement of energy is a fundamental tool used, for example, in exploring the early universe, characterizing particle decay processes, as well as in quantum technology and computing. Some of the most sensitive energy detectors are…
The necessity to increase exposure in rare event searches experiments by maintaining a low energy threshold and a good energy resolution leads to segmented detectors as in EDELWEISS (Dark Matter), CUORE (0{\nu}\b{eta}\b{eta}) or RICOCHET…
A generalized model for the critical temperature Tc of superconducting bilayers is presented, which is valid with no restrictions to film thicknesses, Tc of the layers and interface resistivity. The model is verified experimentally on a…
Next generation cosmic microwave background (CMB) polarimetry experiments aim to deploy order 500,000 detectors, requiring repeatable and reliable fabrication process with stable and uniform transition edge sensor (TES) bolometer…
Future far-infrared astronomy missions will need large arrays of detectors with exceptionally low noise-equivalent power (NEP), with some mission concepts calling for thousands of detectors with NEPs below a few $\times 10^{-20}$…
Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta decay ($\beta\beta0\nu$) require precise energy measurements.…
A high spectral resolution observation of the diffuse X-ray background in the 60 - 1000 eV energy range has been made using an array of thirty-six 1 mm^2 micro-calorimeters flown on a sounding rocket. Detector energy resolution ranged from…
Microcalorimeter instruments aboard future X-ray observatories will require an anti-coincidence (anti-co) detector to veto charged particle events and reduce the non-X-ray background. We have developed a large-format, TES-based prototype…