Related papers: Characterization of a CdZnTe detector for a low-po…
We investigate the performance of large area radiation detectors, with high energy- and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development…
Low noise CCDs fully-depleted up to 675 micrometers have been identified as a unique tool for Dark Matter searches and low energy neutrino physics. The charge collection efficiency (CCE) for these detectors is a critical parameter for the…
CeBr3 is emerging as one of the best scintillators having properties almost similar to Cerium doped lanthanum halide scintillators. We have measured, for the first time, the intrinsic energy resolution of Compton electrons in a cylindrical…
We have developed a large CdTe pixel detector with dimensions of 23.7 x 13.0 mm and a pixel size of 448 x 448 um^2. The detector is based on recent technologies of an uniform CdTe single crystal, a two-dimensional ASIC, and stud…
The use of photon counting detection technology has resulted in significant X-ray imaging research interest in recent years. Computed Tomography (CT) scanners can benefit from photon-counting detectors, which are new technology with the…
Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to 600…
Introduction: The Medium Energy X-ray telescope (ME) is a collimated X-ray telescope onboard the Insight hard X-ray modulation telescope (Insight-HXMT) satellite. It has 1728 Si-PIN pixels readout using 54 low noise application-specific…
We present the design of a Faraday cup-like charged particle detector in a four quadrant configuration aimed at facilitating the alignment of low-intensity beams of exotic particles. The device is capable of assessing the current on the…
The fourth flight of the Focusing Optics X-ray Solar Imager sounding rocket experiment (FOXSI-4) aimed to achieve the first imaging spectroscopic observations of mid-to-large class ( >= GOES C5 class) solar flares, in contrast to the…
LaBr3:Ce crystals, with photomultiplier or single SiPM readout (up to 3x3 mm$^2$) have been introduced for radiation imaging in medical physics. An R&D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize…
Extensive simulations of a portable radiation detecting system have been performed in order to explore important performance parameters. The instrument consists of a stack of ten detecting layers made of pixelated Cadmium Telluride (CdTe)…
In a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, energy resolution is important to distinguish between $0\nu\beta\beta$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy…
We present the results of a beam test conducted on a telescope using the JadePix-3 pixel sensor, developed with TowerJazz 180 nm CMOS imaging technology. The telescope is composed of five planes, each equipped with a JadePix-3 sensor with…
The effect of moderate cooling on CdZnTe semiconductor detectors has been studied for the COBRA experiment. Improvements in energy resolution and low energy threshold were observed and quantified as a function of temperature. Leakage…
A Semiconductor Multiple-Compton Telescope (SMCT) is being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of the SMCT…
DEPFET pixel detectors are unique devices in terms of energy and spatial resolution because very low noise (ENC = 2.2e at room temperature) operation can be obtained by implementing the amplifying transistor in the pixel cell itself. Full…
The detector material Cadmium Zinc Telluride (CZT), known for its high resolution over a broad energy range, is produced mainly by two methods: the Modified High-Pressure Bridgman (MHB) and the High-Pressure Bridgman (HPB) process. This…
We present the results of using standard IMARAD CZT detectors with a 100 MHz readout of the anode and cathode pulses. The detectors, 2 cm x 2 cm large and 0.5 cm thick, have 64 Indium pixellated anode contacts at a pitch of 2.5 mm. We…
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$\Phi$NE collider at LNF,…
We demonstrate a prototype kinetic inductance detector (KID) readout system that uses less than 10 mW per pixel. The CCAT-prime RFSoC based readout is capable of reading four independent detector networks of up to 1000 KIDs each. The power…