English
Related papers

Related papers: Closed-Loop MOEMS Accelerometer

200 papers

In order to increase the measured phase of an atom interferometer and improve its sensitivity, researchers attempt to increase the enclosed space-time area using two methods: creating larger separations between the interferometer arms and…

We theoretically investigate the application of the fringe-locking method (FLM) in the dual-species quantum test of the weak equivalence principle (WEP). With the FLM, the measurement is performed invariably at the midfringe, and the…

Atomic Physics · Physics 2016-03-07 Xiao-Chun Duan , Xiao-Bing Deng , De-Kai Mao , Min-Kang Zhou , Cheng-Gang Shao , Zhong-Kun Hu

The double-pass interferometer scheme was proposed in Ref.\,[Light Sci. Appl. {\bf 7}, 11 (2018)] as the method of implementation of the quantum speed meter concept in future laser gravitational-wave (GW) detectors. Later it was shown in…

General Relativity and Quantum Cosmology · Physics 2025-03-14 L. A. Barinov , F. Ya. Khalili

Optics and more recently coherent matter waves enabled inertial sensors such as accelerometers and gyroscopes to reach high levels of resolution and sensitivity. As these technologies rest on physical phenomena that require particular…

Quantum Physics · Physics 2022-10-18 Ilia Khomchenko , Patrick Navez , Henni Ouerdane

A cavity optomechanical magnetometer is demonstrated where the magnetic field induced expansion of a magnetostrictive material is transduced onto the physical structure of a highly compliant optical microresonator. The resulting motion is…

We propose an optomechanical design, consisting of a parity-time symmetric multilayer structure tuned at exceptional-point degeneracy (EPD), with an adjustable layer that is coupled to micromechanical springs. The deflections of this layer…

Applied Physics · Physics 2020-07-01 Rodion Kononchuk , Tsampikos Kottos

Micro-electro mechanical systems (MEMS) thermal flow sensors are increasingly used for compact, low-power flow monitoring in biomedical applications. However, silicon-based method for sensor fabrication is limited by high cost, rigidity,…

Instrumentation and Detectors · Physics 2025-12-10 Mohammad Nizar Mohamed Zukri , Muhammad Salman Al Farisi , Yoshihiro Hasegawa , Mitsuhiro Shikida

Lab-on-a-chip (LOC) forms the basis of the new-generation portable analytical systems. LOC allows the manipulation of ultralow flows of liquid reagents and multistep reactions on a microfluidic chip, which requires a robust and precise…

Wafer-level testing is an important step for process and quality control of electronic chips in integrated circuit (IC) manufacturing which occurs before packaging. The process of wafer probing in its conventional contacting schemes,…

Optics · Physics 2024-02-29 Maryam Sadat Amiri Naeini , Pierre Berini

Inter satellite laser interferometry is a central component of future space-borne gravity instruments like LISA, eLISA, NGO and future geodesy missions. The inherently small laser wavelength allows to measure distance variations with…

The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the…

Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells…

Applied Physics · Physics 2023-06-30 L. M. Rushton , L. Elson , A. Meraki , K. Jensen

Fiber-based optical microcavities exhibit high quality factor and low mode volume resonances that make them attractive for coupling light to individual atoms or other microscopic systems. Moreover, their low mass should lead to excellent…

Instrumentation and Detectors · Physics 2017-09-04 E. Janitz , M. Ruf , Y. Fontana , J. Sankey , L. Childress

In a previous work, we designed a compact atom interferometer to measure homogeneous constant forces guiding the arms via shortcuts to adiabatic paths. Within this scheme we drive the atom by moving spin-dependent traps, and design a force…

Quantum Physics · Physics 2025-09-12 Sofía Martínez-Garaot , I. Lizuain , A. Rodriguez-Prieto , J. G. Muga

Forces acting between an Atomic Force Microscope (AFM) tip and sample are three dimensional. Despite this, most AFM force measurements are confined to one or two dimensions. Extending AFM force measurements into three dimensions has…

Mesoscale and Nanoscale Physics · Physics 2025-04-21 Roger Proksch , Ryan Wagner

The main contribution of this paper is a high frequency, low-complexity, on-board visual-inertial odometry system for quadrotor micro air vehicles. The system consists of an extended Kalman filter (EKF) based state estimation algorithm that…

Robotics · Computer Science 2016-07-07 Dinuka Abeywardena , Shoudong Huang , Ben Barnes , Gamini Dissanayake , Sarath Kodagoda

We address the challenge of reliable and accurate proprioception in soft robots, specifically those with tight packaging constraints and relying only on internally embedded sensors. While various sensing approaches with single sensors have…

This article presents several design techniques to fabricate micro-electro-mechanical systems (MEMS) using standard complementary metal-oxide semiconductor (CMOS) processes. They were applied to fabricate high yield CMOS-MEMS shielded…

Instrumentation and Detectors · Physics 2021-09-24 Juan Valle , Josep-María Sánchez-Chiva , Daniel Fernández , Jordi Madrenas

We report on the construction and testing of a vacuum-gap Fabry-P\'erot etalon calibrator for high precision radial velocity spectrographs. Our etalon is traced against a rubidium frequency standard to provide a cost effective, yet…

Instrumentation and Methods for Astrophysics · Physics 2017-06-20 Julian Stürmer , Andreas Seifahrt , Christian Schwab , Jacob L. Bean

We use a frequency-dependent electro-optic technique to measure the hole mobility in small molecule organic semiconductors, such as 6,13 bis(triisopropylsilylethynyl)-pentacene. Measurements are made on semiconductor films in bottom gate,…

Materials Science · Physics 2012-12-20 Emily G. Bittle , Joseph W. Brill , Joseph P. Straley