English
Related papers

Related papers: Computational Scatter Correction for High-Resoluti…

200 papers

Scatter signals can degrade the contrast and resolution of computed tomography (CT) images and induce artifacts. How to effectively correct scatter signals in CT has always been a focal point of research for researchers. This work presents…

Medical Physics · Physics 2025-01-10 Guiyuan Lin , Shiwo Deng , Xiaoqun Wang , Xing Zhao

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

Medical Physics · Physics 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies

Scattered coincidences introduce quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction. Conventional scatter estimates typically rely on simplified cylindrical scanner models that omit…

Recently, spectral CT has been drawing a lot of attention in a variety of clinical applications primarily due to its capability of providing quantitative information about material properties. The quantitative integrity of the reconstructed…

Medical Physics · Physics 2018-01-12 Shiyu Xu , Peter Prinsen , Jens Wiegert , Ravindra Manjeshwar

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

Medical Physics · Physics 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

Purpose: Scatter artifacts drastically degrade the image quality of cone-beam computed tomography (CBCT) scans. Although deep learning-based methods show promise in estimating scatter from CBCT measurements, their deployment in mobile CBCT…

Signal Processing · Electrical Eng. & Systems 2025-09-12 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Scatter due to interaction of photons with the imaged object is a fundamental problem in X-ray Computed Tomography (CT). It manifests as various artifacts in the reconstruction, making its abatement or correction critical for image quality.…

Medical Physics · Physics 2024-01-30 Berk Iskender , Yoram Bresler

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

Medical Physics · Physics 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

Monte Carlo algorithms have a growing impact on nuclear medicine reconstruction processes. One of the main limitations of myocardial perfusion imaging (MPI) is the effective mitigation of the scattering component, which is particularly…

Instrumentation and Detectors · Physics 2021-05-28 J. Zhou , A. G. Leja , M. Salvatori , D. Della Latta , A. Di Fulvio

We propose a new modeling approach for scatter estimation and descattering in polyenergetic X-ray computed tomography (CT) based on fitting models to local neighborhoods of a training set. X-ray CT is widely used in medical and industrial…

Image and Video Processing · Electrical Eng. & Systems 2021-09-30 Michael T. McCann , Marc L. Klasky , Jennifer L. Schei , Saiprasad Ravishankar

Multi-MeV flash radiography is often used as the primary diagnostic technique for high energy and density (HED) physics experiments. Primary X-ray which is attenuated by the object offers density information of the object. For a thick metal…

Applied Physics · Physics 2021-12-02 Qinggang Jia , Peng-Cheng Mao , Yang-Bo , Dun-Fu Shi , Ling-Yu Zhang , Deng-Li , Hai-Bo Xu

In this work, we compare one-step and two-step approaches for X-ray computed tomography (CT) scatter correction and density reconstruction. X-ray CT is an important imaging technique in medical and industrial applications. In many cases,…

Image and Video Processing · Electrical Eng. & Systems 2023-01-11 Alexander N. Sietsema , Michael T. McCann , Marc L. Klasky , Saiprasad Ravishankar

In Single Photon Emission Computed Tomography (SPECT), 3D images usually reconstructed by performing a set of bidimensional (2D) analytical or iterative reconstructions can also be reconstructed using an iterative reconstruction algorithm…

Instrumentation and Detectors · Physics 2007-05-23 Z. El Bitar , I. Buvat , V. Breton , D. Lazaro , D. Hill

The fastCAT application uses pre-calculated Monte Carlo (MC) CBCT phantom-specific scatter and detector response functions to reduce simulation time for megavoltage (MV) and kilovoltage (kV) CBCT imaging. Pre-calculated x-ray beam energy…

Medical Physics · Physics 2021-09-15 Jericho O'Connell , Magdalena Bazalova-Carter

Multi-source stationary computed tomography (MSS-CT) offers significant advantages in medical and industrial applications due to its gantry-less scan architecture and/or capability of simultaneous multi-source emission. However, the lack of…

Medical Physics · Physics 2025-01-20 Yingxian Xia , Zhiqiang Chen , Li Zhang , Yuxiang Xing , Hewei Gao

Radiative transfer (RT) simulations are a powerful tool that enables the calculation of synthetic images of a wide range of astrophysical objects. These simulations are often based on the Monte Carlo (MC) method, as it provides the needed…

Instrumentation and Methods for Astrophysics · Physics 2023-11-23 Anton Krieger , Sebastian Wolf

We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed…

Medical Physics · Physics 2015-01-20 Wei Zhao , Jun Zhu , Luyao Wang

Compared to single-source imaging systems, dual-source imaging systems equipped with two cross-distributed scanning beams significantly enhance temporal resolution and capture more comprehensive object scanning information. Nevertheless,…

Medical Physics · Physics 2025-03-19 Jianing Sun , Jigang Duan , Guangyin Li , Xu Jiang , Xing Zhao

X-ray scatter has been a serious concern in computed tomography (CT), leading to image artifacts and distortion of CT values. The linear Boltzmann transport equation (LBTE) is recognized as a fast and accurate approach for scatter…

Medical Physics · Physics 2025-08-29 Guoxi Zhu , Li Zhang , Zhiqiang Chen , Hewei Gao

In Cone-Beam CT (CBCT) imaging systems, the scattering phenomenon has a significant impact on the reconstructed image and is a long-lasting research topic on CBCT. In this paper, we propose a simple, novel and fast approach for mitigating…

Medical Physics · Physics 2016-04-07 Shi-peng Xie , Rui-ju Yan
‹ Prev 1 2 3 10 Next ›