Image reconstruction in Single Photon Emission Computed Tomography (SPECT) is affected by physical effects such as photon attenuation, Compton scatter and detector response. These effects can be compensated for by modeling the corresponding…
Sparse-view Computed Tomography (CT) image reconstruction is a promising approach to reduce radiation exposure, but it inevitably leads to image degradation. Although diffusion model-based approaches are computationally expensive and suffer…
Quantitative photoacoustic tomography aims at estimating optical parameters from photoacoustic images that are formed utilizing the photoacoustic effect caused by the absorption of an externally introduced light pulse. This optical…
Context: The Monte Carlo method is probably the most widely used approach to solve the radiative transfer problem, especially in a general 3D geometry. The physical processes of emission, absorption, and scattering are easily incorporated…
Several models for the simulation of photon elastic scattering are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. They include models based on the form factor approximation,…
To maximize the accuracy of background simulation and event reconstruction, high-energy neutrino telescopes require detailed knowledge of light propagation over a large volume of detection medium. If light scattering and absorption leng ths…
The dominant image-to-image translation methods are based on fully convolutional networks, which extract and translate an image's features and then reconstruct the image. However, they have unacceptable computational costs when working with…
In x-ray coherent scatter tomography, tomographic measurements of the forward scatter distribution are used to infer scatter densities within a volume. A radiopaque 2D pattern placed between the object and the detector array enables the…
By considering the effect of varying the target radii and detector aperture width on the scattering angle in experimental Compton scattering, mathematical models were developed and subsequently incorporated into Monte Carlo simulations. By…
Monte Carlo (MC) simulation is commonly considered to be the most accurate dose calculation method in radiotherapy. However, its efficiency still requires improvement for many routine clinical applications. In this paper, we present our…
Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image…
In this work we present a novel 3D Monte Carlo photon transport program for simulation of multiple refractive scattering based on the refractive properties of X-rays in highly scattering media, like lung tissue. Multiple scattering reduces…
Indirect imaging problems in biomedical optics generally require repeated evaluation of forward models of radiative transport, for which Monte Carlo is accurate yet computationally costly. We develop a novel approach to reduce this…
Computed Tomography (CT) is a widely used technology that requires compute-intense algorithms for image reconstruction. We propose a novel back-projection algorithm that reduces the projection computation cost to 1/6 of the standard…
Monte Carlo simulations are a crucial tool for the analysis and prediction of various background components in liquid xenon (LXe) detectors. With improving shielding in new experiments, the simulation of external backgrounds, such as…
One native source of quality deterioration in medical imaging, and especially in our case optical coherence tomography (OCT), is the turbid biological media in which photon does not take a predictable path and many scattering events would…
Objective: The aim of this study is to validate the effectiveness of an energy-modulated scatter correction method in suppressing scatter in photon-counting detector (PCD)-based cone beam CT (CBCT) imaging. Approach: The scatter correction…
We discuss the efficiency of Monte Carlo methods in solving continuum radiative transfer problems. The sampling of the radiation field and convergence of dust temperature calculations in the case of optically thick clouds are both studied.…
X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and opaque instruments. In most commercial x-ray modalities, an image is formed by measuring the x-rays that pass through the object of…
Modeling of the collimator-detector response (CDR) in SPECT reconstruction enables improved resolution and accuracy, and is thus important for quantitative imaging applications such as dosimetry. The implementation of CDR modeling, however,…