Related papers: A Highly Drift-stable Atomic Magnetometer for Fund…
We use femtosecond optical pulses to induce, control and monitor magnetization precession in ferromagnetic Ga0.965Mn0.035As. At temperatures below ~40 K we observe coherent oscillations of the local Mn spins, triggered by an ultrafast…
This paper describes the results of the most recent measurement of the permanent electric dipole moment (EDM) of neutral $^{199}$Hg atoms. Fused silica vapor cells containing enriched $^{199}$Hg are arranged in a stack in a common magnetic…
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout…
We present a new design of highly specialized small storage rings for low energy polarized electron beams. The new design is based on the transparent spin methodology that cancels the spin precession due to the magnetic dipole moment at any…
We present a novel approach allowing an optically pumped magnetometer (OPM) to be operated within Earth's magnetic field as a vector magnetometer whose sensitive axis can be freely defined. This approach enables the measurement of any…
We demonstrate a minimally-destructive in situ technique for measuring and stabilizing slowly-drifting magnetic fields in ultracold-atom experiments. While conventional magnetic-field sensors such as Hall, giant magnetoresistive, or…
Optically pumped atomic magnetometers (OPAMs) offer high sensitivity at room temperature and are increasingly considered for portable magnetic sensing in geomagnetic-field environments. Here we report a handheld-scale, single-beam scalar…
Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb 85 atoms, in response to change in longitudinal magnetic field (\delta B_z ) is demonstrated…
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a "dead zone," making them…
Optically pumped magnetometers (OPMs) based on alkali-atom vapors are ultra-sensitive devices for dc and low-frequency ac magnetic measurements. Here, in combination with fast-field-cycling hardware and high-resolution spectroscopic…
We report on the design and performance of a highly sensitive combined $^3$He/Cs magnetometer for the absolute measurement of magnetic fields. The magnetometer relies on the magnetometric detection of the free spin precession of nuclear…
We use the technique of chopped nonlinear magneto-optic rotation (NMOR) in a room temperature $^{133}$Cs vapor cell to measure the permanent electric dipole moment (EDM) in the atom. The cell has paraffin coating on the walls to increase…
An all-optical atomic magnetometer is used to detect a proton free-precession signal from a water sample polarized in a 0.7 T field and remotely analyzed in a 4 $\mu T$ field. Nuclear spins are manipulated either by $\pi/2$ pulses or by…
We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D$_2$ line. A wide frequency…
For precision atomic magnetometry, inert buffer gas is included in alkali-metal vapor cells to significantly broaden hyperfine transitions, which facilitates optical pumping and reduces diffusive relaxation, while also providing…
We have performed a comparison of laser (LsOPM) and lamp (LpOPM) pumped cesium vapor magnetometers. Although the LsOPM operated 50% above its shot-noise limit we found an intrinsic sensitivity of 15 fT/\sqrt{Hz} and 25 fT/\sqrt{Hz} for the…
The operation of a high sensitive atomic magnetometer using resonant elliptically polarized light is demonstrated. The experimental geometry allows autonomous frequency stabilization of the laser, thereby offers compact operation of the…
We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The device will be…
We study the effect of optical polarization squeezing on the performance of a sensitive, quantum-noise-limited optically pumped magnetometer. We use Bell-Bloom (BB) optical pumping to excite a $^{87}$Rb vapor containing $8.2 \cdot 10^{12}…
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells…