Related papers: Slice-selective Zero Echo Time imaging of ultra-sh…
T2 weighted imaging of the spine is commonly performed using fast spin echo (FSE/TSE) based sequences, resulting in long scan times and vulnerability to motion artifacts. While single shot fast spin echo sequences have been attempted, their…
UTE (Ultrashort Echo Time) and ZTE (Zero Echo Time) sequences have been developed to detect short T2 relaxation signals coming from regions that are unable to be detected by conventional MRI methods. Due to the high dipole-dipole…
Purpose: To develop schemes that deliver faithful 2D slices near field heterogeneities of the kind arising from non-ferromagnetic metal implants, with reduced artifacts and shorter scan times. Methods: An excitation scheme relying on…
Multicomponent T2-mapping using a gradient and spin-echo (GraSE) acquisition has become standard for myelin water imaging at 3T. Higher magnetic field strengths promise SNR benefits but face specific absorption rate limits and shortened T2…
Purpose: To rapidly obtain high isotropic-resolution T2 maps with whole-brain coverage and high geometric fidelity. Methods: A T2 blip-up/down echo planar imaging (EPI) acquisition with generalized Slice-dithered enhanced resolution…
Spin-based quantum computing and magnetic resonance techniques rely on the ability to measure the coherence time, T2, of a spin system. We report on the experimental implementation of all-optical spin echo to determine the T2 time of a…
A model-based reconstruction technique for accelerated T2 mapping with improved accuracy is proposed using undersampled Cartesian spin-echo MRI data. The technique employs an advanced signal model for T2 relaxation that accounts for…
Purpose: To propose and evaluate an accelerated $T_{1\rho}$ quantification method that combines $T_{1\rho}$-weighted fast spin echo (FSE) images and proton density (PD)-weighted anatomical FSE images, leveraging deep learning models for…
Low-field T2 mapping MRI can democratize neuropediatric imaging by improving accessibility and providing quantitative biomarkers of brain development. \textbf{Purpose:} To evaluate the feasibility of high-resolution T2 mapping using a…
Motion-robust 2D Radial Turbo Spin Echo (RADTSE) pulse sequence can provide a high-resolution composite image, T2-weighted images at multiple echo times (TEs), and a quantitative T2 map, all from a single k-space acquisition. In this work,…
Relaxometry studies in preterm and at-term newborns have provided insight into brain microstructure, thus opening new avenues for studying normal brain development and supporting diagnosis in equivocal neurological situations. However, such…
There has been increased interest in the quantitative characterization of tissues based on T2 in abdominal imaging. Techniques based on spin-echo or turbo spin-echo sequences are time consuming because they require multiple acquisitions for…
Radiofrequency (RF) pulses are a critical part of every MRI pulse sequence, and must be specifically designed for ultrashort echo time (UTE) and zero echo time (ZTE) acquisitions. When considering the behavior of RF pulses, most often…
Fast spin-echo (FSE) pulse sequences for Magnetic Resonance Imaging (MRI) offer important imaging contrast in clinically feasible scan times. T2-shuffling is widely used to resolve temporal signal dynamics in FSE acquisitions by exploiting…
Objective: To demonstrate the effectiveness of using a deep learning-based approach for a fully automated slice-based measurement of muscle mass for assessing sarcopenia on CT scans of the abdomen without any case exclusion criteria.…
Purpose: To develop and evaluate a free-breathing respiratory motion compensated 4D (3D+respiration) $T_2$-weighted turbo spin echo sequence with application to radiology and MR-guided radiotherapy. Methods: k-space data are continuously…
Cardiac magnetic resonance (CMR) imaging and computed tomography (CT) are two common non-invasive imaging methods for assessing patients with cardiovascular disease. CMR typically acquires multiple sparse 2D slices, with unavoidable…
In the last few years, with the rapid development of deep learning technologies, supervised methods based on convolutional neural networks have greatly enhanced the performance of medical image denoising. However, these methods require…
Purpose: To demonstrate an ultrashort echo time magnetic resonance fingerprinting (UTE-MRF) method that can simultaneously quantify tissue relaxometries for muscle and bone in musculoskeletal systems and tissue components in brain and…
Current MRI super-resolution (SR) methods only use existing contrasts acquired from typical clinical sequences as input for the neural network (NN). In turbo spin echo sequences (TSE) the sequence parameters can have a strong influence on…