English
Related papers

Related papers: One-step inversion algorithms for spectral CT, wit…

200 papers

Dual-energy computed tomography (DECT) is a promising technology that has shown a number of clinical advantages over conventional X-ray CT, such as improved material identification, artifact suppression, etc. For proton therapy treatment…

Background: Dual-energy imaging on cone-beam CT (CBCT) scanners has great potential in different clinical applications, including image-guided surgery and adaptive proton therapy. However, the clinical practice of dual-energy CBCT (DE-CBCT)…

Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…

Medical Physics · Physics 2022-05-24 Junbo Peng

We develop a primal-dual algorithm that allows for one-step inversion of spectral CT transmission photon counts data to a basis map decomposition. The algorithm allows for image constraints to be enforced on the basis maps during the…

Medical Physics · Physics 2016-05-04 Rina Foygel Barber , Emil Y. Sidky , Taly Gilat Schmidt , Xiaochuan Pan

Abstract Objective. Cone-beam computed tomography is becoming more and more popular in applications such as 3D dental imaging. Iterative methods compared to the standard Feldkamp algorithm have shown improvements in image quality of…

Signal Processing · Electrical Eng. & Systems 2024-11-15 Louise Friot-Giroux , Françoise Peyrin , Voichita Maxim

Spectral CT offers enhanced material discrimination over single-energy systems and enables quantitative estimation of basis material density images. Water/iodine decomposition in contrast-enhanced CT is one of the most widespread…

Medical Physics · Physics 2021-03-30 Matthew Tivnan , Grace Gang , Wenchao Cao , Nadav Shapira , Peter B. Noel , J. Webster Stayman

Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT…

Background: Dual-energy (DE) imaging techniques in cone-beam computed tomography (CBCT) have potential clinical applications, including material quantification and improved tissue visualization. However, the performance of DE CBCT is…

Medical Physics · Physics 2023-06-26 Cem Altunbas

Objective: Quantitative technique based on In-line phase-contrast computed tomography with single scanning attracts more attention in application due to the flexibility of the implementation. However, the quantitative results usually suffer…

Medical Physics · Physics 2022-06-13 Suyu Liao , Shiwo Deng , Yining Zhu , Huitao Zhang , Peiping Zhu , Kai Zhang , Xing Zhao

Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed to provide respiratory phase resolved volumetric imaging in image guided radiation therapy (IGRT). Inadequate number of projections in each phase bin results in low…

Medical Physics · Physics 2015-06-03 Xun Jia , Zhen Tian , Yifei Lou , Jan-Jakob Sonke , Steve B. Jiang

In a standard computed tomography (CT) image, pixels having the same Hounsfield Units (HU) can correspond to different materials and it is therefore challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable to…

Medical Physics · Physics 2020-10-27 Wei Zhao , Tianling Lyu , Yang Chen , Lei Xing

Background: Limited-angle (LA) dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations…

Inferior soft-tissue contrast resolution is a major limitation of current CT scanners. The aim of the study is to improve the contrast resolution of CT scanners using dual-energy acquisition. Based on dual-energy material decomposition, the…

Medical Physics · Physics 2016-11-15 Wei Zhao , Lu Wan , Bo Zhang , Qiude Zhang , Tianye Niu

Purpose: This study proposes a systematic method for determining the optimal x-ray tube settings/energy windows and fluence for minimal noise and maximum CNR in material density images obtained from DECT scans by fixing the subject size and…

Medical Physics · Physics 2023-08-02 Fatma Terzioglu , Emil Y. Sidky , Jp Phillips , Ingrid Reiser , Guillaume Bal , Xiaochuan Pan

In a standard computed tomography (CT) image, pixels having the same Hounsfield Units (HU) can correspond to different materials and it is, therefore, challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable…

Medical Physics · Physics 2019-11-01 Wei Zhao , Tianling Lv , Peng Gao , Liyue Shen , Xianjin Dai , Kai Cheng , Mengyu Jia , Yang Chen , Lei Xing

Computed tomography (CT) has been developed as a non-destructive technique for observing minute internal images of samples. It has been difficult to obtain photo-realistic (clean or clear) CT images due to various unwanted artifacts…

Quantum Physics · Physics 2023-09-12 Kyungtaek Jun

Cone-beam computed tomography (CBCT) offers advantages over conventional fan-beam CT in that it requires a shorter time and less exposure to obtain images. CBCT has found a wide variety of applications in patient positioning for…

Computer Vision and Pattern Recognition · Computer Science 2020-07-01 S. Kida , S. Kaji , K. Nawa , T. Imae , T. Nakamoto , S. Ozaki , T. Ohta , Y. Nozawa , K. Nakagawa

Dual-energy CT (DECT) has been widely investigated to generate more informative and more accurate images in the past decades. For example, Dual-Energy Alternating Minimization (DEAM) algorithm achieves sub-percentage uncertainty in…

Image and Video Processing · Electrical Eng. & Systems 2021-08-03 Tao Ge , Maria Medrano , Rui Liao , David G. Politte , Jeffrey F. Williamson , Joseph A. O'Sullivan

This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…

Computational Engineering, Finance, and Science · Computer Science 2020-10-09 T. Bayaraa , C. M. Hyun , T. J. Jang , S. M. Lee , J. K. Seo

In this work, we compare one-step and two-step approaches for X-ray computed tomography (CT) scatter correction and density reconstruction. X-ray CT is an important imaging technique in medical and industrial applications. In many cases,…

Image and Video Processing · Electrical Eng. & Systems 2023-01-11 Alexander N. Sietsema , Michael T. McCann , Marc L. Klasky , Saiprasad Ravishankar
‹ Prev 1 2 3 10 Next ›