Related papers: Radiation damage on SiPMs for Space Applications
Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…
During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the…
Many of the characteristics of Silicon Photomultipliers (SiPMs), such as high Photon Detection Efficiency (PDE), are well matched to the requirements of the cameras of the Small-Sized Telescopes (SSTs) proposed for the Cherenkov Telescope…
The Silicon Electron Multiplier (SiEM) is a novel sensor concept for minimum ionizing particle (MIP) detection which uses internal gain and fine pitch to achieve excellent temporal and spatial resolution. In contrast to sensors where the…
We describe a novel high-speed front-end electronic board (FEB) for interfacing an array of 32 Silicon Photo-multipliers (SiPM) with a computer. The FEB provides individually adjustable bias on the SiPMs, and performs low-noise analog…
There exists an enormous interest for the study of very high energy domain in particle physics, both theoretically and experimentally, in the aim to construct a general theory of the fundamental constituents of matter and of their…
Plastic scintillators are widely used as particle detectors in many fields, mainly, medicine, particle physics and astrophysics. Traditionally, they are coupled to a photo-multplier (PMT) but now silicon photo-multipliers (SiPM) are…
Here we report the results of an investigation into the effects of ionizing radiation on commercial-off-the-shelf InGaAs and Si photodiodes. The photodiodes were exposed to 30, 52, and 98 MeV protons with fluences ranging from 10^8 -…
Pixel detectors are used in the innermost part of multi purpose experiments at the Large Hadron Collider (LHC) and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of…
The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations…
Decreasing the operation temperature of a Silicon Photo-Multiplier (SiPM) leads to a drop in its dark noise. Some experiments consider cold temperatures as an option for low noise applications of SiPM. One of those is the TAO detector,…
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from…
Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers…
The first six months of flight data from the Multiband Imaging Photometer for Spitzer (MIPS) were used to test MIPS reduction algorithms based on extensive preflight laboratory data and modeling. The underlying approach for the preflight…
Metalenses are optical devices that implement nanostructures as phase shifters to focus incident light. Their compactness and simple fabrication make them a potential cost-effective solution for increasing light collection efficiency in…
The KLOE electromagnetic calorimeter is expected to be reused in the Near Detector complex of the DUNE experiment at Fermilab. The possible substitution of traditional Photomultiplier Tubes (PMTs) with Silicon Photomultipliers (SiPMs) in…
Silicon Photomultipliers (SiPMs) are an excellent candidate for the development of large-area light sensors. Large SiPM-based detectors require low-noise pre-amplifiers to maximize the signal coupling between the sensor and the readout…
Silicon photomultipliers (SiPMs) have become the baseline choice for cameras of the small-sized telescopes (SSTs) of the Cherenkov Telescope Array (CTA). On the other hand, SiPMs are relatively new to the field and covering large surfaces…
Photomultiplier tube (PMT) and Silicon Photo Multiplier (SiPM) are often used for detecting small number of photons or very weak radiations. A light guide usually connects these photodetectors to the test space. In this article, we…
The scheduled High Luminosity upgrade of the CERN Large Hadron Collider presents new challenges in terms of radiation hardness. As a consequence, campaigns to qualify the radiation hardness of detector sensors and components are undertaken…