English
Related papers

Related papers: Improvement of radon detector performance by using…

200 papers

Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes…

Instrumentation and Detectors · Physics 2024-01-30 D. Wiebe , S. Lindemann , M. Schumann

The radioactive noble gas radon can be a serious background source in the underground particle physics experiments studying processes that deposit energy comparable to its decay products. Low energy solar neutrino measurements at…

Instrumentation and Detectors · Physics 2020-10-12 Y. Nakano , T. Hokama , M. Matsubara , M. Miwa , M. Nakahata , T. Nakamura , H. Sekiya , Y. Takeuchi , S. Tasaka , R. A. Wendell

Radon and its progenies are significant sources of background in rare event detection experiments, including dark matter searches like the PandaX-4T experiment and other rare decay studies such as neutrinoless double beta decay (NLDBD). In…

Instrumentation and Detectors · Physics 2025-07-02 Yuan Wu , Lin Si , Zhicheng Qian , Youhui Yun , Yue Meng , Jianglai Liu , Zhixing Gao , Hao Wang , Liangyu Wu , Yuanzi Liang

Radon and radon daughters pose significant backgrounds to rare-event searching experiments. Activated carbon, which has very strong adsorption capacity for radon, can be used for radon removal and radon enrichment. The internal $^{226}$Ra…

Instrumentation and Detectors · Physics 2022-02-16 Y. Y. Chen , Y. P. Zhang , Y. Liu , J. C. Liu , C. Guo , P. Zhang , S. K. Qiu , C. G. Yang , Q. Tang

In low-background particle physics experiments, surface deposition of radon progeny presents a significant background challenge. To characterize this contamination, a high-sensitivity surface $\alpha$-activity measurement system was…

Instrumentation and Detectors · Physics 2026-03-03 C. B. Z. Luo , C. Guo , L. P. Xiang , Y. H. Niu , F. G. Mo , J. C. Liu , Y. P. Zhang , C. G. Yang

Radon is a naturally occurring radioactive gas that contributes significantly to human radiation exposure and must be controlled to avoid concentrations harmful to health. The paper presents an impulse-proportional ionization chamber that…

Instrumentation and Detectors · Physics 2025-12-25 Ralf Nötzel , Kerstin Weinberg

An active device for radon detection in the air was developed. The monitor operates in pulse counting mode for real-time continuous measurements. The presented prototype has a relatively simple design made of low-price and easy to acquire…

Instrumentation and Detectors · Physics 2020-05-20 Soraia Elisio , Luis Peralta

The NEXT-100 detector at the LSC aims at the first competitive search for the \bbnonu decay using a high-pressure \Xe{136} electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to…

High Energy Physics - Experiment · Physics 2026-04-23 NEXT Collaboration , C. Cortes-Parra , P. Novella , G. Martínez-Lema , H. Almazán , V. Álvarez , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , Y. Ayyad , C. D. R. Azevedo , F. Ballester , J. E. Barcelon , M. del Barrio-Torregrosa , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodoline , N. Byrnes , A. Castillo , E. Church , M. Cid , X. Cid , C. A. N. Conde , F. P. Cossío , R. Coupe , E. Dey , P. Dietz , C. Echeverria , M. Elorza , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , P. Ferrero Mancheño , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , J. W. R. Grocott , R. Guenette , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , A. F. B. Isabel , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. Marauri , A. P. Marques , J. Martín-Albo , A. Martínez , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , D. R. Nygren , E. Oblak , I. Osborne , J. Palacio , B. Palmeiro , A. Para , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , E. Ruiz-Chóliz , P. Saharia , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , A. L. M. Silva , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , S. Torelli , J. Torrent , A. Trettin , P. R. G. Valle , M. Vanga , P. Vázquez Cabaleiro , J. F. C. A. Veloso , J. D. Villamil , L. M. Villar Padruno , J. Waiton , A. Yubero-Navarro

The radioactive noble gas $^{222}$Rn, which can be dissolved in water, is an important background source for JUNO. In this paper, based on the water system of JUNO prototype, two kinds of high sensitivity radon detectors have been proposed…

Instrumentation and Detectors · Physics 2017-12-15 Y. P. Zhang , J. C. Liu , C. Guo , Y. B. Huang , Z. Y. Yu , C. Xu , M. Y. Guan , C. G. Yang , P. Zhang

To precisely measure radon concentrations in purified air supplied to the Super-Kamiokande detector as a buffer gas, we have developed a highly sensitive radon detector with an intrinsic background as low as 0.33$\pm$0.07 mBq/m$^{3}$. In…

Instrumentation and Detectors · Physics 2017-04-25 Y. Nakano , H. Sekiya , S. Tasaka , Y. Takeuchi , R. A. Wendell , M. Matsubara , M. Nakahata

The XENONnT experiment has achieved an exceptionally low $^\text{222}$Rn activity concentration within its inner 5.9$\,$tonne liquid xenon detector of (0.90$\,\pm\,$0.01$\,$stat.$\,\pm\,$0.07 sys.)$\,\mu$Bq/kg, equivalent to about 430…

Instrumentation and Detectors · Physics 2025-04-28 E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , A. Brown , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , S. el Morabit , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , M. Galloway , F. Gao , S. Ghosh , R. Giacomobono , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , P. Kavrigin , S. Kazama , P. Kharbanda , M. Kobayashi , D. Koke , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , Z. Liang , Y. -T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , E. Masson , S. Mastroianni , A. Melchiorre , J. Merz , M. Messina , A. Michael , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , L. Principe , J. Qi , J. Qin , D. Ramírez García , M. Rajado , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , J. Shi , M. Silva , H. Simgen , C. Szyszka , A. Takeda , Y. Takeuchi , P. -L. Tan , D. Thers , F. Toschi , G. Trinchero , C. D. Tunnell , F. Tönnies , K. Valerius , S. Vecchi , S. Vetter , F. I. Villazon Solar , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong

Conventional LIDAR systems require hundreds or thousands of photon detections to form accurate depth and reflectivity images. Recent photon-efficient computational imaging methods are remarkably effective with only 1.0 to 3.0 detected…

Applications · Statistics 2019-11-13 Joshua Rapp , Vivek K Goyal

The radioactive daughters isotope of 222Rn are one of the highest risk contaminants in liquid xenon detectors aiming for a small signal rate. The noble gas is permanently emanated from the detector surfaces and mixed with the xenon target.…

Instrumentation and Detectors · Physics 2018-03-14 Natascha Rupp

Radioactivity from radon is a major threat for high-precision low energy physics experiments like the ones in the Kamioka Mine. We developed a new high sensitive radon monitoring system and conducted systematic radon concentration…

Instrumentation and Detectors · Physics 2019-06-04 Guillaume Pronost , Motoyasu Ikeda , Taku Nakamura , Hiroyuki Sekiya , Shigeki Tasaka

The LZ dark matter detector, like many other rare-event searches, will suffer from backgrounds due to the radioactive decay of radon daughters. In order to achieve its science goals, the concentration of radon within the xenon should not…

Instrumentation and Detectors · Physics 2018-01-17 E. H. Miller , J. Busenitz , T. K. Edberg , C. Ghag , C. Hall , R. Leonard , K. Lesko , X. Liu , Yue Meng , A. Piepke , R. W. Schnee

We construct a high sensitivity radon pilot detector using liquid scintillator dissolved radon for the CDEX rare-event searches program. The CDEX-10 project employs a germanium detector array immersed in a massive liquid nitrogen tank.…

Instrumentation and Detectors · Physics 2024-05-16 Qian-Yun Li , Ming-Xuan Li , Ren-Ming-Jie Li , Shin-Ted Lin , Shu-Kui Liu , Chang-Jian Tang , Hao-Yang Xing , Jing-Jun Zhu , Qian Yue , Li-Tao Yang

The radiation emitted from radon is a critical background in rare event search experiments conducted at the Yemi Underground Laboratory (Yemilab) in Jeongseon, Korea. A Radon Reduction System(RRS) has been developed and installed in Yemilab…

Instrumentation and Detectors · Physics 2024-05-09 Kyungmin Seo , Hyunsoo Kim , Yeongduk Kim , Hyeyoung Lee , Jaison Lee , Moo Hyun Lee , Jungho So , Sangcheol Yoon , Youngsoo Yoon

Precise radon measurements are a requirement for various applications, ranging from radiation protection over environmental studies to material screening campaigns for rare-event searches. All of them ultimately depend on the availability…

Instrumentation and Detectors · Physics 2023-01-25 Florian Jörg , Guillaume Eurin , Hardy Simgen

A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…

Astrophysics · Physics 2009-11-11 Hua Feng , Philip Kaaret , Hans Andersson

The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of…

‹ Prev 1 2 3 10 Next ›