Related papers: Improvement of radon detector performance by using…
The background caused by radon and its daughters is an important background in the low background liquid scintillator (LS) detectors. The study of the diffusion behaviour of radon in the LS contributes to the analysis of the related…
In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector---a high sensitivity, low cost, and real-time radon monitor based on \textit{Topmetal-${II}^-$} time projection chamber (TPC). Using…
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly…
The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. $^{222}$Rn produces a particularly…
A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…
We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From…
The NA62 RICH detector is used for the separation of pions and muons in the momentum range 15 -- 35 GeV/c and is expected to provide a muon suppression factor better than $10^{-2}$. A prototype of the final detector equipped with about 400…
The next generation low-background detectors operating deep underground aim for unprecedented low levels of radioactive backgrounds. The deposition and presence of radon progeny on detector surfaces is an added source of energetic…
In an infrared photodetector, noise current (dark current) is generated throughout the volume of the detector. Reducing the volume will reduce dark current, but the corresponding smaller area will also reduce the received signal. By using a…
We present the results of the operation of an array of avalanche photodiodes (APDs) for the readout of an electroluminescence detector. The detector contains 24 APDs with a pitch of 15 mm between them allowing energy and position…
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of…
The Chinese large-area violet-light-sensitive silicon photodiode PIN is one of the candidates of the lead tungstate crystal detector readout component of the photon spectrometer in the large heavy ion collision experiment. The PIN diode was…
A systematic study of the indoor airborne radon concentration in the central part of the Nicosia district was conducted, using high-sensitivity active radon portable detectors of the type "RADIM3A". From a total of 108 measurements in 54…
Measuring radon emanation from detector materials is a key method for controlling radon, a significant background in rare-event physics experiments. Methods for measuring radon emanation are well-established but have predominantly focused…
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at…
We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of…
Radon is one of the most important sources of background in rare event search experiments, such as those searching for Dark Matter and neutrinos, due to its unavoidable production from natural uranium. In low-background experiments, radon…
The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multipurpose underground liquid scintillator detector, was proposed for the determination of the neutrino mass hierarchy as primary physics goal. The central detector will be…
In order to enhance LIDAR performance metrics such as target detection sensitivity, noise resilience and ranging accuracy, we exploit the strong temporal correlation within the photon pairs generated in continuous-wave pumped semiconductor…
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at…