Related papers: Material radiopurity control in the XENONnT experi…
The GERDA experiment aims to search for the neutrinoless double beta-decay of 76Ge and possibly for other rare processes. The sensitivity of the first phase is envisioned to be more than one order of magnitude better than in previous…
A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K,…
The background caused by radon and its daughters is an important background in the low background liquid scintillator (LS) detectors. The study of the diffusion behaviour of radon in the LS contributes to the analysis of the related…
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this…
The radioactive noble gas $^{222}$Rn, which can be dissolved in water, is an important background source for JUNO. In this paper, based on the water system of JUNO prototype, two kinds of high sensitivity radon detectors have been proposed…
The Jiangmen Underground Neutrino Observatory (JUNO), a 20~kton multi-purpose low background Liquid Scintillator (LS) detector, was proposed primarily to determine the neutrino mass ordering. To suppress the radioactivity from the…
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at…
The next generation low-background detectors operating deep underground aim for unprecedented low levels of radioactive backgrounds. The deposition and presence of radon progeny on detector surfaces is an added source of energetic…
We developed a highly sensitive, reliable and portable automatic system (H$^{3}$) to monitor the radon concentration of the underground experimental halls of the Daya Bay Reactor Neutrino Experiment. H$^{3}$ is able to measure radon…
The NEXT-100 detector will search for the neutrinoless double beta decay of $^{136}$Xe using an electroluminescent high-pressure xenon gas TPC filled with 100 kg of enriched Xe. An observation of this hypothetical process would establish a…
Radon-induced backgrounds, particularly from $^{222}$Rn and its beta-emitting progeny, present a critical challenge for next-generation liquid xenon (LXe) detectors aimed at probing dark matter down to the neutrino fog. To address this, we…
The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. $^{222}$Rn produces a particularly…
We examine the recently-reported low-energy electron recoil spectrum observed at the XENON1T underground dark matter direct detection experiment, in the context of new interactions with solar neutrinos. In particular we show that scalar and…
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time…
We discuss an in-situ evaluation of the $^{85}$Kr, $^{222}$Rn, and $^{220}$Rn background in PandaX-I, a 120-kg liquid xenon dark matter direct detection experiment. Combining with a simulation, their contributions to the low energy…
Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…
A quantitative study of the neutron environment in the Canfranc Underground Laboratory has been performed. The analysis is based on a complete set of simulations and, particularly, it is focused on the IGEX-DM dark matter experiment. The…
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that…
Using the Geant4 toolkit, a Monte-Carlo code to simulate the detector background of the Simbol-X focal plane instrument has been developed with the aim to optimize the design of the instrument. Structural design models of the mirror and…
We show that the excess in electron recoil events seen by the XENON1T experiment can be explained by relatively low-mass Luminous Dark Matter candidate. The dark matter scatters inelastically in the detector (or the surrounding rock), to…