English
Related papers

Related papers: Endoscopic en-face optical coherence tomography an…

200 papers

Non-destructive testing (NDT) is crucial for ensuring product quality and safety across various industries. Conventional methods such as ultrasonic, terahertz, and X-ray imaging have limitations in terms of probe-contact requirement, depth…

Endoscopic imaging is essential for real-time visualization of internal organs, yet conventional systems remain bulky, complex, and expensive due to their reliance on large, multi-element optical components. This limits their accessibility…

Optical coherence tomography (OCT) is one of the non-invasive and easy-to-acquire biomarkers (the thickness of the retinal layers, which is detectable within OCT scans) being investigated to diagnose Alzheimer's disease (AD). This work aims…

Image and Video Processing · Electrical Eng. & Systems 2022-06-14 Paria Jeihouni , Omid Dehzangi , Annahita Amireskandari , Ali Dabouei , Ali Rezai , Nasser M. Nasrabadi

For a unified analysis of medical images from different modalities, data harmonization using image-to-image (I2I) translation is desired. We study this problem employing an optical coherence tomography (OCT) data set of Spectralis-OCT and…

Image and Video Processing · Electrical Eng. & Systems 2024-04-09 Marc S. Seibel , Hristina Uzunova , Timo Kepp , Heinz Handels

Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image…

Medical Physics · Physics 2013-04-09 Kun Wang , Chao Huang , Yu-Jiun Kao , Cheng-Ying Chou , Alexander A. Oraevsky , Mark A. Anastasio

Optical Coherence Tomography(OCT) is a non-invasive technique capturing cross-sectional area of the retina in micro-meter resolutions. It has been widely used as a auxiliary imaging reference to detect eye-related pathology and predict…

Image and Video Processing · Electrical Eng. & Systems 2022-09-01 Shuo Chen , Da Ma , Sieun Lee , Timothy T. L. Yu , Gavin Xu , Donghuan Lu , Karteek Popuri , Myeong Jin Ju , Marinko V. Sarunic , Mirza Faisal Beg

We demonstrate a different scheme to perform optical sectioning of a sample based on the concept of induced coherence [Zou et al., Phys. Rev. Lett. 67, 318 (1991)]. This can be viewed as a different type of optical coherence tomography…

Quantum Physics · Physics 2018-02-19 Adam Vallés , Gerard Jiménez , Luis José Salazar-Serrano , Juan P. Torres

We propose and experimentally demonstrate temporally low-coherent optical diffraction tomography (ODT) based on angle-scanning Mach-Zehnder interferometry. Using a digital micromirror device based on diffractive tilting, we successfully…

Optics · Physics 2018-07-17 KyeoReh Lee , Seungwoo Shin , Zahid Yaqoob , Peter T. C. So , YongKeun Park

Two-Photon Laser-Scanning Microscopy is a powerful tool for exploring biological structure and function because of its ability to optically section through a sample with a tight focus. While it is possible to obtain 3D image stacks by…

Biological Physics · Physics 2020-01-08 Courtney Johnson , Jack Exell , Jonathon Kuo , Kevin Welsher

Optical coherence tomography (OCT) is a prevalent imaging technique for retina. However, it is affected by multiplicative speckle noise that can degrade the visibility of essential anatomical structures, including blood vessels and tissue…

Image and Video Processing · Electrical Eng. & Systems 2021-07-12 Dewei Hu , Joseph D. Malone , Yigit Atay , Yuankai K. Tao , Ipek Oguz

Dynamic full-field optical coherence tomography (D-FFOCT) has recently emerged as a label-free imaging tool, capable of resolving cell types and organelles within 3D live samples, whilst monitoring their activity at tens of milliseconds…

Optical Deflectometric Tomography (ODT) provides an accurate characterization of transparent materials whose complex surfaces present a real challenge for manufacture and control. In ODT, the refractive index map (RIM) of a transparent…

Computer Vision and Pattern Recognition · Computer Science 2013-10-31 Adriana Gonzalez , Laurent Jacques , Christophe De Vleeschouwer , Philippe Antoine

Quantum Optical Coherence Tomography (Q-OCT) presents many advantages over its classical counterpart, Optical Coherence Tomography (OCT): it provides an increased axial resolution and is immune to even orders of dispersion. The core of…

Quantum Physics · Physics 2021-03-30 Jakub Szlachetka , Sylwia Kolenderska , Piotr Kolenderski

A polarization-multiplexed, dual-beam setup is proposed to expand the field of view for a swept source optical coherence tomography angiography (OCTA) system. This method used a Wollaston prism to split sample path light into two…

Medical Physics · Physics 2017-10-30 Jianlong Yang , Rahul Chandwani , Rui Zhao , Zhuo Wang , Yali Jia , David Huang , Gangjun Liu

We present differential phase-contrast optical coherence tomography (DPC-OCT) with two transversally separated probing beams to sense phase gradients in various directions by employing a rotatable Wollaston prism. In combination with a…

Optics · Physics 2011-11-11 Bettina Heise , David Stifter

We introduce a novel laser-scanning optical microscopy technique that employs optical-frequency-comb (OFC) lasers. This method facilitates multimodal spectroscopic imaging by analyzing interferograms produced via a dual-comb spectroscopic…

Diabetic Retinopathy (DR), an ocular complication of diabetes, is a leading cause of blindness worldwide. Traditionally, DR is monitored using Color Fundus Photography (CFP), a widespread 2-D imaging modality. However, DR classifications…

Many eye diseases like Diabetic Macular Edema (DME), Age-related Macular Degeneration (AMD), and Glaucoma manifest in the retina, can cause irreversible blindness or severely impair the central version. The Optical Coherence Tomography…

Image and Video Processing · Electrical Eng. & Systems 2023-03-10 Nchongmaje Ndipenoch , Alina Miron , Zidong Wang , Yongmin Li

Optical coherent tomography (OCT) fingerprint technology provides rich depth information, including internal fingerprint (papillary junction) and sweat (eccrine) glands, in addition to imaging any fake layers (presentation attacks) placed…

Computer Vision and Pattern Recognition · Computer Science 2019-08-02 Tarang Chugh , Anil K. Jain

Despite significant advances in artificial intelligence (AI) for computer vision, its application in medical imaging has been limited by the burden and limits of expert-generated labels. We used images from optical coherence tomography…

Computer Vision and Pattern Recognition · Computer Science 2018-02-27 Cecilia S. Lee , Ariel J. Tyring , Yue Wu , Sa Xiao , Ariel S. Rokem , Nicolaas P. Deruyter , Qinqin Zhang , Adnan Tufail , Ruikang K. Wang , Aaron Y. Lee