English
Related papers

Related papers: Radio-frequency C-V measurements with sub-attofara…

200 papers

We present a method for absolute calibration of received radio-frequency in the ultra low frequency (ULF), and very low frequency (VLF) range. This is achieved with the use of a radio frequency optically pumped magnetometer (RF-OPM). We…

Superconducting coplanar waveguide resonators that can operate in strong magnetic fields are important tools for a variety of high frequency superconducting devices. Magnetic fields degrade resonator performance by creating Abrikosov…

We have fabricated arrays of High-T$_c$ Superconducting Quantum Interference Devices (SQUIDs) with randomly distributed loop sizes as sensitive antennas for Radio-Frequency (RF) waves. These sub-wavelength size devices known as…

We describe instrumentation for conducting high sensitivity millimeter-wave cavity perturbation measurements over a broad frequency range (40-200 GHz) and in the presence of strong magnetic fields (up to 33 tesla). A Millimeter-wave Vector…

Materials Science · Physics 2009-10-31 M. Mola , S. Hill , P. Goy , M. Gross

A new type of quartz resonance device for measurements of oscillations of the contact potential difference induced by modulated light is described. Special attention is devoted to the compensation of the constructive capacitance of the…

Instrumentation and Detectors · Physics 2015-02-26 Vasil G. Yordanov , Todor M. Mishonov

The accuracy of microwave measurements is not only critical for applications in telecommunication and radar, but also for future quantum computers. Qubit technologies such as superconducting qubits or spin qubits require detecting minuscule…

Quantum Physics · Physics 2023-03-14 N. Crescini , E. G. Kelly , G. Salis , A. Fuhrer

We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these…

This work analyzes resonance frequency shift vs. the applied magnetic field strength for GHz operating GaN/Si SAW single resonators. Magnetostrictive elements (Ni and CoFeB) were deposited in the proximity of the interdigitated transducers…

The implementation of a quantum computer requires a qubit-specific measurement capability to read-out the final state of a quantum system. The model of spin dependent tunneling followed by charge readout has been highly successful in…

Mesoscale and Nanoscale Physics · Physics 2015-04-07 M. F. Gonzalez-Zalba , A. J. Ferguson , S. Barraud , A. C. Betz

Voltage-tunable superconductor-semiconductor devices offer a unique platform to realize dynamic tunability in superconducting quantum circuits. By galvanically connecting a gated InAs-Al Josephson junction to a coplanar waveguide resonator,…

Absorbed power of nanoparticles during magnetic hyperthermia can be well determined from changes in the quality factor ($Q$ factor) of a resonator, in which the radiofrequency (RF) absorbent is placed. We present an order of magnitude…

Applied Physics · Physics 2019-07-17 I. Gresits , Gy. Thuróczy , O. Sági , I. Homolya , G. Bagaméry , D. Gajári , M. Babos , P. Major , B. G. Márkus , F. Simon

The design and performance of an electron spin resonance spectrometer operating at 3 and 9 GHz microwave frequencies combined with a 9 T superconducting magnet is described. The probehead contains a compact two-loop, one gap resonator and…

Other Condensed Matter · Physics 2009-11-10 Ferenc Simon , Ferenc Muranyi

We present superconducting microwave-frequency resonators based on NbTiN nanowires. The small cross section of the nanowires minimizes vortex generation, making the resonators resilient to magnetic fields. Measured intrinsic quality factors…

Mesoscale and Nanoscale Physics · Physics 2016-04-13 N. Samkharadze , A. Bruno , P. Scarlino , G. Zheng , D. P. DiVincenzo , L. DiCarlo , L. M. K. Vandersypen

Nano electromechanical systems are considered as ultra sensitive devices for mass and force detection. Capacitive actuation is widely used in these devices but is known to degrade the quality factor of the resonator due to DC electrostatic…

Mesoscale and Nanoscale Physics · Physics 2016-07-27 T Barois , S Perisanu , P Poncharal , Philippe Vincent , A Ayari

Recent advancement in superconducting radio frequency cavity processing techniques, with diffusion of impurities within the RF penetration depth, resulted in high quality factor with increase in quality factor with increasing accelerating…

Superconductivity · Physics 2023-08-22 N. K. Raut , B. D. Khanal , J. K. Tiskumara , S. De Silva , P. Dhakal , G. Ciovati1 , J. R. Delayen

In multi-qubit superconducting systems utilizing flip-chip technology, achieving high accuracy in resonator frequencies is of paramount importance, particularly when multiple resonators share a common Purcell filter with restricted…

Quantum Physics · Physics 2023-12-12 Yuan Li , Tianhui Wang , Jingjing Hu , Dengfeng Li , Shuoming An

The variation of the resonance frequency and intrinsic quality factor of superconducting radio-frequency cavities during the transition from the superconducting to the normal-conducting state provides essential insight into the fundamental…

Capacitance-voltage ($\textit{C-V}$) traces in n-type-(Bi$_{1-x}$Sb$_x$)$_2$Te$_3$/oxide/metal capacitor structures using an AC capacitance bridge are investigated. By tuning the top gate voltage from positive to negative values, the system…

Mesoscale and Nanoscale Physics · Physics 2019-07-30 Jimin Wang , Markus Schitko , Gregor Mussler , Detlev Grützmacher , Dieter Weiss

We demonstrate a dynamic scanning capacitance microscope (DSCM) that operates at large bandwidths, cryogenic temperatures and high magnetic fields. The setup is based on a non-contact atomic force microscope (AFM) with a quartz tuning fork…

Instrumentation and Detectors · Physics 2009-03-12 A. Baumgartner , M. E. Suddards , C. J. Mellor

We present measurements of a hybrid system consisting of a microwave transmission-line resonator and a lateral quantum dot defined on a GaAs heterostructure. The two subsystems are separately characterized and their interaction is studied…

Mesoscale and Nanoscale Physics · Physics 2011-06-30 T. Frey , P. J. Leek , M. Beck , K. Ensslin , A. Wallraff , T. Ihn