Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field,…
Solid-state scintillators are widely used in particle and applied physics due to their versatility and resistance to diverse environments and operating conditions. This broad range of applications calls for thorough characterization of…
We have measured scintillation properties of pure CsI crystals used in the shower calorimeter built for a precise determination of the pi+ -> pi0 e+ nu decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals painted…
In this paper the growth of a 16mm diameter Ce-doped Tl$_2$NaYCl$_6$ and its characterization as a gamma-ray detector are reported. With a 16 mm dia. x 8 mm cylindrical sample, energy resolution of 4.1% (FWHM) at 662 keV and light yield of…
The last years have seen the first cryogenic detectors to be proposed for usage on balloon-borne missions. In such missions, the instrument will be exposed to the high radiation environment of the upper atmosphere. This radiation can induce…
Using highly monochromatic synchrotron X-rays in the energy range from 10.5 keV to 100 keV the temperature dependence of nonproportionality and energy resolution of LaBr3 scintillators doped with 5% Ce3+ were studied at 80K, 295K, and 450K.…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
This study aims to provide an accurate estimation of the intrinsic resolution of LaBr$_3$(Ce) crystal through a combination of experimental and simulation methods. We re-analyzed the data from previous Wide-Angle Compton Coincidence (WACC)…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…
Fluctuations in photon production in scintillator could contribute to the total energy resolution of a scintillation detector. This contribution, called intrinsic resolution (IR), is one of the factors limiting the total energy resolution…
The HERMES (High Energy Rapid Modular Ensemble of Satellites) Pathfinder mission aims to develop a constellation of nanosatellites to study astronomical transient sources, such as gamma-ray bursts, in the X and soft $\gamma$ energy range,…
A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With…
The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels…
A simplified digital spectrometer for the study of $\gamma$-rays with energies up to $\sim100$ MeV is presented and tested. The spectrometer is only consisted of a fast digital oscilloscope and three scintillation detectors which can work…
We investigate the performance of large area radiation detectors, with high energy- and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development…
A new type of compact high resolution high sensitivity gamma ray spectrometer for short pulse intense 250 keV to 50 MeV gamma rays has been developed by combining the principles of scintillators and attenuation spectrometers. The first…
We have characterized two state-of-the-art solid-state photomultipliers, one by SensL, the other by Hamamatsu, coupled to scintillators by Saint-Gobain Crystals in the -25 to 50 degrees C temperature range. At room temperature, the energy…
This article describes the crystal selection and quality control utilized to develop and calibrate a high resolution array of CsI(TI) scintillator crystals for the detection of energetic charged particles. Alpha sources are used to test the…
The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever…
$Cs_2LiYCl_6:Ce^{3+}$ (CLYC) is an inorganic scintillator that has recently garnered attention for its ability to detect and discriminate between gammas and thermal neutrons. We investigate several important performance parameters of three…