Related papers: Exceeding the limits of algorithmic self-calibrati…
Fourier ptychographic microscopy (FPM) is a recently developed imaging modality that uses angularly varying illumination to extend a system performance beyond the limit defined by its optical elements. The FPM technique applies a novel…
Camera calibration is integral to robotics and computer vision algorithms that seek to infer geometric properties of the scene from visual input streams. In practice, calibration is a laborious procedure requiring specialized data…
Achieving high spatial resolution is the goal of many imaging systems. Designing a high-resolution lens with diffraction-limited performance over a large field of view remains a difficult task in imaging system design. On the other hand,…
The most prevalent routine for camera calibration is based on the detection of well-defined feature points on a purpose-made calibration artifact. These could be checkerboard saddle points, circles, rings or triangles, often printed on a…
X-ray imaging is a fundamental tool of routine clinical diagnosis. Fluoroscopic imaging can further acquire X-ray images at video frame rates, thus enabling non-invasive in-vivo motion studies of joints, gastrointestinal tract, etc. For…
In coherent X-ray diffraction microscopy the diffraction pattern generated by a sample illuminated with coherent x-rays is recorded, and a computer algorithm recovers the unmeasured phases to synthesize an image. By avoiding the use of a…
While Fourier ptychography (FP) offers super-resolution for macroscopic imaging, its real-world application is severely hampered by atmospheric turbulence, a challenge largely unaddressed in existing macroscopic FP research operating under…
Diffraction-limited imaging in epi-fluorescence microscopy remains a challenge when sample aberrations are present or when the region of interest rests deep within an inhomogeneous medium. Adaptive optics is an attractive solution albeit…
We report a novel generalized optical measurement system and computational approach to determine and correct aberrations in optical systems. We developed a computational imaging method capable of reconstructing an optical system's…
\textbf{Purpose:} C-arm fluoroscopy's 3D reconstruction relies on accurate intrinsic calibration, which is often challenging in clinical practice. This study ensures high-precision reconstruction accuracy by re-optimizing the extrinsic…
Super-resolution fluorescence microscopy is an important tool in biomedical research for its ability to discern features smaller than the diffraction limit. However, due to its difficult implementation and high cost, the universal…
Following the recent developement of Fourier ptychographic microscopy (FPM) in the visible range by Zheng et al. (2013), we propose an adaptation for hard x-rays. FPM employs ptychographic reconstruction to merge a series of low-resolution,…
Fourier ptychographic microscopy allows for the collection of images with a high space-bandwidth product at the cost of temporal resolution. In Fourier ptychographic microscopy, the light source of a conventional widefield microscope is…
Precise sensor calibration is critical for autonomous vehicles as a prerequisite for perception algorithms to function properly. Rotation error of one degree can translate to position error of meters in target object detection at large…
Fourier ptychographic microscopy (FPM) is a powerful computational imaging modality that achieves high space-bandwidth product imaging for biomedical samples. However, its adoption is limited by slow data acquisition due to the need for…
We investigate methods to calibrate the non-common path aberrations at an adaptive optics system having a wavefront-correcting device working at an extremely high resolution (larger than 150x150). We use focal-plane images collected…
Fourier ptychography microscopy (FPM) is a new computational imaging technique that can provide gigapixel images with both high resolution and a wide field of view (FOV). However, time consuming of the data-acquisition process is a critical…
Fourier ptychography has attracted a wide range of focus for its ability of large space-bandwidth-produce, and quantative phase measurement. It is a typical computational imaging technique which refers to optimizing both the imaging…
The reconstruction fidelity of computational optical imaging is fundamentally constrained by the model-reality gap, i.e., the inevitable discrepancy between idealized forward models and the physical imaging process. Conventional paradigms…
In 3D reconstruction, the recovery of the calibration parameters of the cameras is paramount since it provides metric information about the observed scene, e.g., measures of angles and ratios of distances. Autocalibration enables the…