English
Related papers

Related papers: A novel range telescope concept for proton CT

200 papers

The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power…

The major advantage of proton therapy over conventional radiotherapy is the dose deposition pattern, enabling precise coverage of the tumour volume while sparing nearby healthy tissues. However, accurate control of the proton beam range…

Medical Physics · Physics 2025-04-01 Magdalena Kołodziej

In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner.…

Medical Physics · Physics 2026-01-05 S. Vrbaški , G. Stanić , S. Molinelli , M. Bhattarai , E. Abadi , M. Ciocca , E. Samei

We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of…

Hadrontherapy is a novel technique of cancer radiation therapy which employs beams of charged hadrons, protons and carbon ions in particular. Due to their physical and radiobiological properties, they allow one to obtain a more conformal…

Medical Physics · Physics 2015-05-14 Saverio Braccini

Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become…

We summarize recent results and ongoing activities in mathematical algorithms and computer science methods related to proton computed tomography (pCT) and intensity-modulated particle therapy (IMPT) treatment planning. Proton therapy…

Medical Physics · Physics 2021-08-24 Yair Censor , Keith E. Schubert , Reinhard W. Schulte

For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray…

Proton radiography is used for advanced hydrotesting as a new type radiography technology due to its powerful penetration capability and high detection efficiency. A new proton radiography terminal will be developed to radiograph static…

Accelerator Physics · Physics 2015-01-28 Yan Yan , Li-Na Sheng , Zhi-Wu Huang , Jie Wang , Ze-En Yao , Jun-Run Wang , Zheng Wei , Jian-Cheng Yang , You-Jin Yuan

Proton therapy is nowadays becoming a wide spread clinical practice in cancer therapy and sophisticated treatment planning systems are routinely used to exploit at best the ballistic properties of charged particles. The information on the…

Medical Physics · Physics 2015-05-14 S. Braccini , A. Ereditato , I. Kreslo , U. Moser , C. Pistillo , P. Scampoli , S. Studer

Photon-counting computed tomography (PCCT) marks a significant advancement over conventional energy-integrating detector (EID) CT systems. This review highlights PCCT's superior spatial and contrast resolution, reduced radiation dose, and…

Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue…

PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements…

Proton computed tomography (pCT) aims to facilitate precise dose planning for hadron therapy, a promising and effective method for cancer treatment. Hadron therapy utilizes protons and heavy ions to deliver well focused doses of radiation,…

We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast…

Range uncertainties in proton therapy hamper treatment precision. Prompt gamma-rays were suggested 16 years ago for real-time range verification, and have already shown promising results in clinical studies with collimated cameras.…

Medical Physics · Physics 2021-12-07 F. Hueso-González , T. Bortfeld

Proton therapy systems without a gantry can be more compact and less expensive in terms of capital cost, and therefore more available to a larger patient population. Would the advances in pencil beam scanning and robotics make gantry-less…

Proton (and ion) cancer therapy has proven to be an extremely effective even supe-rior method of treatment for some tumors 1-4. A major problem, however, lies in the cost of the particle accelerator facilities; high procurement costs…

In this work, we propose a novel technique for in-vivo proton therapy range verification. This technique makes use of a small hadron tumour marker, $^{92}$Mo, implanted at a short known distance from the clinical treatment volume. Signals…

Proton therapy is an emerging method in cancer therapy. One of the main developments is to increase the accuracy of the Bragg-peak position calculation, which requires more precise relative stopping power (RSP) measurements. A promising…

Medical Physics · Physics 2026-02-18 Gábor Bíró , Ákos Sudár , Zsófia Jólesz , Gábor Papp , Gergely Gábor Barnaföldi