English
Related papers

Related papers: Beam test performance of a highly granular silicon…

200 papers

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL of the International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future…

Instrumentation and Detectors · Physics 2020-06-17 D. Breton , A. Irles , J. Jeglot , J. Maalmi , R. Pöschl , D. Zerwas

The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors,…

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future International…

Instrumentation and Detectors · Physics 2020-04-28 Adrian Irles

The Particle Flow Algorithms adopted for future $e^{+}e^{-}$ colliders detectors and phase-II CMS upgrade require very high granularity calorimeters to deconvolve the individual contributions of particles in jets. This is especially true…

Instrumentation and Detectors · Physics 2017-11-27 Kostiantyn Shpak

The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a…

In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number…

The highly granular silicon-tungsten electromagnetic calorimeter (SiW ECAL) is the reference design of the ECAL for the International Large Detector (ILD) concept, one of the two detector concepts proposed for the future International…

Instrumentation and Detectors · Physics 2020-06-24 Adrian Irles

A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2.…

Instrumentation and Detectors · Physics 2017-07-24 CALICE Collaboration

High precision physics at future colliders as the International Linear Collider (ILC) require unprecedented high precision in the determination of the energy of final state particles. The needed precision will be achieved thanks to the…

Instrumentation and Detectors · Physics 2018-02-27 Adrián Irles

The next generation of collider detectors will make full use of Particle Flow Algorithms, requiring high-precision tracking and full imaging calorimeters. The latter, thanks to granularity improvements by two to three orders of magnitude…

Instrumentation and Detectors · Physics 2022-11-15 Roman Pöschl

An innovative path for the detectors at future colliders to achieve higher performances is to use a Particle Flow approach, which requires highly granular calorimeters to image individual showers. The silicon-tungsten electromagnetic…

Instrumentation and Detectors · Physics 2026-05-01 Yukun Shi , Vincent Boudry

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high…

Instrumentation and Detectors · Physics 2009-09-29 CALICE Collaboration , J. Repond , J. Yu , C. M. Hawkes , Y. Mikami , O. Miller , N. K. Watson , J. A. Wilson , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , F. Badaud , D. Boumediene , C. Carloganu , R. Cornat , P. Gay , Ph. Gris , S. Manen , F. Morisseau , L. Royer , G. C. Blazey , D. Chakraborty , A. Dyshkant , K. Francis , D. Hedin , G. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , E. Garutti , V. Korbel , F. Sefkow , M. Groll , G. Kim , D-W. Kim , K. Lee , S. Lee , K. Kawagoe , Y. Tamura , D. A. Bowerman , P. D. Dauncey , A. -M. Magnan , C. Noronha , H. Yilmaz , O. Zorba , V. Bartsch , J. M. Butterworth , M. Postranecky , M. Warren , M. Wing , M. Faucci Giannelli , M. G. Green , F. Salvatore , T. Wu , D. Bailey , R. J. Barlow , M. Kelly , S. Snow , R. J. Thompson , M. Danilov , V. Kochetkov , N. Baranova , P. Ermolov , D. Karmanov , M. Korolev , M. Merkin , A. Voronin , B. Bouquet , S. Callier , F. Dulucq , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , M. Ruan , N. Seguin-Moreau , F. Wicek , Z. Zhang , M. Anduze , V. Boudry , J-C. Brient , C. Clerc , G. Gaycken , C. Jauffret , A. Karar , P. Mora de Freitas , G. Musat , M. Reinhard , A. Rouge , A. L. Sanchez , J-Ch. Vanel , H. Videau , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , Yu. Arestov , A. Baird , R. N. Halsall , S. W. Nam , I. H. Park , J. Yang

Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We discuss the tests of the first three 18x18 cm$^2$ layers segmented into 1024 pixels of the technological prototype of…

Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We describe the R&D program of the large scale detector element with up to 12 000 readout channels for the International…

Instrumentation and Detectors · Physics 2018-04-18 V. Balagura

The basic prototype of a tile hadron calorimeter (HCAL) for the International Linear Collider (ILC) has been realised and extensively tested. A major aspect of the proposed concept is the improvement of the jet energy resolution by…

Instrumentation and Detectors · Physics 2016-10-10 Aliakbar Ebrahimi

The FCAL collaboration is preparing large-scale prototypes of special calorimeters to be used in the very forward region at future electron-positron colliders for a precise measurement of integrated luminosity and for instant luminosity…

Instrumentation and Detectors · Physics 2021-01-22 Maryna Borysova

Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high…

Instrumentation and Detectors · Physics 2015-03-31 T. Suehara , H. Hirai , H. Sumida , H. Ueno , Y. Sudo , T. Yoshioka , K. Kawagoe

Studies of the response of the SiD silicon-tungsten electromagnetic calorimeter (ECal) are presented. Layers of highly granular (13 mm^2 pixels) silicon detectors embedded in thin gaps (~ 1 mm) between tungsten alloy plates give the SiD…

Instrumentation and Detectors · Physics 2017-03-28 Amanda Steinhebel , James Brau

An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common…

High Energy Physics - Experiment · Physics 2023-04-28 Vincent Boudry

The CALICE collaboration is preparing large scale prototypes for highly granular calorimeters for detectors to be operated at a future linear electron positron collider. Currently a prototype of a SiW electromagnetic calorimeter is…

Instrumentation and Detectors · Physics 2019-08-13 Roman Pöschl
‹ Prev 1 2 3 10 Next ›