Commissioning of the highly granular SiW-ECAL technological prototype
Instrumentation and Detectors
2019-04-05 v2
Abstract
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number similar to that envisaged for e.g. the ILD Detector of the International Linear Collider (ILC). The analysis demonstrates the capability of the detector to record signals as low as 0.5 MIP. Further, no loss of performance has been observed when operating the detector in a high magnetic field.
Keywords
Cite
@article{arxiv.1810.05133,
title = {Commissioning of the highly granular SiW-ECAL technological prototype},
author = {S. Bilokin and J. Bonis and P. Cornebise and A. Gallas and A. Irles and R. Pöschl and F. Richard and A. Thiebault and D. Zerwas and M. Anduze and V. Balagura and V. Boudry and J-C. Brient and E. Edy and G. Fayolle and M. Frotin and F. Gastaldi and A. Lobanov and F. Magniette and J. Nanni and M. Rubio-Roy and K. Shpak and H. Videau and D. Yu and S. Callier and F. Dulucq and Ch. de la Taille and N. Seguin-Moreau and J. E. Augustin and R. Cornat and J. David and P. Ghislain and D. Lacour and L. Lavergne and J. M. Parraud and K. Kawagoe and Y. Miura and I. Sekiya and T. Suehara and H. Yamashiro and T. Yoshioka and D. Jeans and J. S. Chai},
journal= {arXiv preprint arXiv:1810.05133},
year = {2019}
}