Related papers: Correcting inter-scan motion artefacts in quantita…
Purpose: Bilateral Orthogonality Generative Acquisitions (BOGA) method, which was initially implemented for T_2^* contrast via gradient echo acquisitions, is adapted for TSE imaging at 7T using parallel transmission (pTx) system for…
Magnetic Resonance Imaging (MRI) acquisitions require extensive scan times, limiting patient throughput and increasing susceptibility to motion artifacts. Accelerated parallel MRI techniques reduce acquisition time by undersampling k-space…
Purpose: Ultra-high-field 7T MRI offers improved resolution and contrast over standard clinical field strengths (1.5T, 3T). However, 7T scanners are costly, scarce, and introduce additional challenges such as susceptibility artifacts. We…
In many applications of tomography, the acquired projections are either limited in number or contain a significant amount of noise. In these cases, standard reconstruction methods tend to produce artifacts that can make further analysis…
Purpose: To develop an accelerated Cartesian MRF implementation using a multi-shot EPI sequence for rapid simultaneous quantification of T1 and T2 parameters. Methods: The proposed Cartesian MRF method involved the acquisition of highly…
Visual odometry and Simultaneous Localization And Mapping (SLAM) has been studied as one of the most important tasks in the areas of computer vision and robotics, to contribute to autonomous navigation and augmented reality systems. In case…
Motion correction (MoCo) in radial MRI is a particularly challenging problem due to the unpredictability of subject movement. Current state-of-the-art (SOTA) MoCo algorithms often rely on extensive high-quality MR images to pre-train neural…
Increasing demand for high field magnetic resonance (MR) scanner indicates the need for high-quality MR images for accurate medical diagnosis. However, cost constraints, instead, motivate a need for algorithms to enhance images from low…
We propose a novel method for non-rigid 3-D motion correction of orthogonally raster-scanned optical coherence tomography angiography volumes. This is the first approach that aligns predominantly axial structural features like retinal…
Purpose: To achieve automatic hyperparameter estimation for the joint recovery of quantitative MR images, we propose a Bayesian formulation of the reconstruction problem that incorporates the signal model. Additionally, we investigate the…
Emotion recognition from facial videos enables non-contact inference of human emotional states. Although facial expressions are widely used cues, they cannot fully reflect intrinsic affective states. Remote photoplethysmography (rPPG)…
Knowledge of the noise distribution in diffusion MRI is the centerpiece to quantify uncertainties arising from the acquisition process. Accurate estimation beyond textbook distributions often requires information about the acquisition…
The most prevalent routine for camera calibration is based on the detection of well-defined feature points on a purpose-made calibration artifact. These could be checkerboard saddle points, circles, rings or triangles, often printed on a…
Relative pose estimation is a fundamental problem in computer vision and it has been studied for conventional global shutter cameras for decades. However, recently, a rolling shutter camera has been widely used due to its low cost imaging…
Ultra-high resolution 7 tesla (7T) magnetic resonance imaging (MRI) provides detailed anatomical views, offering better signal-to-noise ratio, resolution and tissue contrast than 3T MRI, though at the cost of accessibility. We present an…
We present a general solution for the radiation intensity in front of a purely absorbing slab moving toward an observer at constant speed and with a constant temperature. The solution is obtained by integrating the lab-frame radiation…
Three-dimensional x-ray CT image reconstruction in baggage scanning in security applications is an important research field. The variety of materials to be reconstructed is broader than medical x-ray imaging. Presence of high attenuating…
The quality of datasets is a critical issue in big data mining. More interesting things could be mined from datasets with higher quality. The existence of missing values in geographical data would worsen the quality of big datasets. To…
Routine clinical imaging of the retina using optical coherence tomography (OCT) is performed with large slice spacing, resulting in highly anisotropic images and a sparsely scanned retina. Most learning-based methods circumvent the problems…
In the case of vector flow imaging systems, the most employed flow estimation techniques are the directional beamforming based cross correlation and the triangulation-based autocorrelation. However, the directional beamforming-based…