Significance: Dynamic photoacoustic computed tomography (PACT) is a valuable technique for monitoring physiological processes. However, current dynamic PACT techniques are often limited to 2D spatial imaging. While volumetric PACT imagers…

Signal Processing · Electrical Eng. & Systems 2023-10-03 Refik M. Cam , Chao Wang , Weylan Thompson , Sergey A. Ermilov , Mark A. Anastasio , Umberto Villa

The reconstruction of dynamic positron emission tomography (PET) images from noisy projection data is a significant but challenging problem. In this paper, we introduce an unsupervised learning approach, Non-negative Implicit Neural…

Computer Vision and Pattern Recognition · Computer Science 2025-06-25 Chaozhi Zhang , Wenxiang Ding , Roy Y. He , Xiaoqun Zhang , Qiaoqiao Ding

This paper evaluates the performance of supervised and unsupervised deep learning models for denoising positron emission tomography (PET) images in the presence of reduced acquisition times. Our experiments consider 212 studies (56908…

Image and Video Processing · Electrical Eng. & Systems 2023-03-29 Ivan Kruzhilov , Stepan Kudin , Luka Vetoshkin , Elena Sokolova , Vladimir Kokh

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes…

Image and Video Processing · Electrical Eng. & Systems 2024-04-18 Shaoyan Pan , Elham Abouei , Junbo Peng , Joshua Qian , Jacob F Wynne , Tonghe Wang , Chih-Wei Chang , Justin Roper , Jonathon A Nye , Hui Mao , Xiaofeng Yang

Positron Emission Tomography scan images are extensively used in radiotherapy planning, clinical diagnosis, assessment of growth and treatment of a tumor. These all rely on fidelity and speed of detection and delineation algorithm. Despite…

Medical Physics · Physics 2017-10-25 Yeman B. Hagos , Vu H. Minh , Saed Khawaldeh , Usama Pervaiz , Tajwar A. Aleef

Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly…

Large high-quality medical image datasets are difficult to acquire but necessary for many deep learning applications. For positron emission tomography (PET), reconstructed image quality is limited by inherent Poisson noise. We propose a…

Positron Emission Tomography (PET) is a powerful medical imaging technique, but the design and evaluation of new PET scanner technologies present significant challenges. The process is typically divided into three major stages: 1. detector…

Instrumentation and Detectors · Physics 2026-01-30 J. Renner , J. J. Gómez-Cadenas , R. Soleti

Ultrafast Electron Microscopy (UEM) has been demonstrated to be an effective table-top technique for imaging the temporally-evolving dynamics of matter with subparticle spatial resolution on the time scale of atomic motion. However, imaging…

Optics · Physics 2017-08-02 M. Th. Hassan , J. S. Baskin , B. Liao , A. H. Zewail

The objective of this study was to develop a PET tumor-segmentation framework that addresses the challenges of limited spatial resolution, high image noise, and lack of clinical training data with ground-truth tumor boundaries in PET…

Time-of-flight positron emission tomography (TOF-PET) detectors exhibiting multiple coincidence time resolution (CTR) components, such as those induced by the mixing of Cherenkov and scintillation photons, have attracted increasing…

Medical Physics · Physics 2026-05-29 Kibo Ote , Fumio Hashimoto , Yuya Onishi , Ryosuke Ota , Maxime Toussaint , Francis Loignon-Houle

This work is the second part of a simulation study investigating the processing of densely packed and moving granular assemblies by positron emission particle tracking (PEPT). Since medical PET scanners commonly used for PEPT are very…

A standard dose of radioactive tracer must be delivered into the patients body to obtain high-quality Positron Emission Tomography (PET) images for diagnostic purposes, which raises the risk of radiation harm. A reduced tracer dose, on the…

As a sensitive functional imaging technique, positron emission tomography (PET) plays a critical role in early disease diagnosis. However, obtaining a high-quality PET image requires injecting a sufficient dose (standard dose) of…

Image and Video Processing · Electrical Eng. & Systems 2024-12-06 Caiwen Jiang , Mianxin Liu , Kaicong Sun , Dinggang Shen

Dual-energy computed tomography (DECT) is a promising technology that has shown a number of clinical advantages over conventional X-ray CT, such as improved material identification, artifact suppression, etc. For proton therapy treatment…

This paper presents a novel method for the reconstruction of high-resolution temporal images in dynamic tomographic imaging, particularly for discrete objects with smooth boundaries that vary over time. Addressing the challenge of limited…

Image and Video Processing · Electrical Eng. & Systems 2023-11-10 Ajinkya Kadu , Felix Lucka , Kees Joost Batenburg

Dual-energy CT (DECT) has been widely investigated to generate more informative and more accurate images in the past decades. For example, Dual-Energy Alternating Minimization (DEAM) algorithm achieves sub-percentage uncertainty in…

Image and Video Processing · Electrical Eng. & Systems 2021-08-03 Tao Ge , Maria Medrano , Rui Liao , David G. Politte , Jeffrey F. Williamson , Joseph A. O'Sullivan

Subject motion in whole-body dynamic PET introduces inter-frame mismatch and seriously impacts parametric imaging. Traditional non-rigid registration methods are generally computationally intense and time-consuming. Deep learning approaches…

Image and Video Processing · Electrical Eng. & Systems 2022-06-29 Xueqi Guo , Bo Zhou , David Pigg , Bruce Spottiswoode , Michael E. Casey , Chi Liu , Nicha C. Dvornek

To obtain high-quality positron emission tomography (PET) while minimizing radiation exposure, a range of methods have been designed to reconstruct standard-dose PET (SPET) from corresponding low-dose PET (LPET) images. However, most…

Image and Video Processing · Electrical Eng. & Systems 2024-04-11 Yuchen Fei , Yanmei Luo , Yan Wang , Jiaqi Cui , Yuanyuan Xu , Jiliu Zhou , Dinggang Shen

In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…