English
Related papers

Related papers: Model-based iterative reconstruction for spectral-…

200 papers

A neural-network (NN)-based method for high-speed, high-definition dynamic optical coherence tomography (DOCT) using full-field swept-source optical coherence microscopy (FF-SS-OCM) is demonstrated. FF-SS-OCM provides high-definition OCT…

Non-contact measurement of the refractive index and thickness of multilayer biological tissues is of great significance for biomedical applications and can greatly improve medical diagnosis and treatment. In this work, we introduce a…

Optics · Physics 2024-04-19 Yu-Lin Ku , Yao-Gen Shu

Fourier reconstruction algorithms significantly outperform conventional back-projection algorithms in terms of computation time. In photoacoustic imaging, these methods require interpolation in the Fourier space domain, which creates…

Numerical Analysis · Mathematics 2016-11-17 M. Haltmeier , O. Scherzer , G. Zangerl

We consider the problem of reconstructing the position and the time-dependent optical properties of a linear dispersive medium from OCT measurements. The medium is multi-layered described by a piece-wise inhomogeneous refractive index. The…

Numerical Analysis · Mathematics 2024-02-23 Peter Elbau , Leonidas Mindrinos , Leopold Veselka

This paper aims to evaluate mid-infrared (MIR) Optical Coherence Tomography (OCT) systems as a tool to penetrate different materials and detect sub-surface irregularities. This is useful for monitoring production processes, allowing…

This work is concerned with applying iterative image reconstruction, based on constrained total-variation minimization, to low-intensity X-ray CT systems that have a high sampling rate. Such systems pose a challenge for iterative image…

Medical Physics · Physics 2016-11-17 Emil Y. Sidky , Rick Chartrand , Yuval Duchin , Christer Ullberg , Xiaochuan Pan

X-Ray based computed tomography (CT) is a well-established technique for determining the three-dimensional structure of an object from its two-dimensional projections. In the past few decades, there have been significant advancements in the…

Medical Physics · Physics 2023-04-26 Dinesh Kumar , Dilworth Y. Parkinson , Jeffrey J. Donatelli

Processing of Diffusion MRI data obtained from High Angular Resolution measurements consists of a series of steps, starting with the estimation of an orientation distribution function (ODF), which is then used as input for e.g. tractography…

Numerical Analysis · Mathematics 2015-12-23 T. Hohage , C. Rügge

This paper proposes a spatial-Radon domain CT image reconstruction model based on data-driven tight frames (SRD-DDTF). The proposed SRD-DDTF model combines the idea of joint image and Radon domain inpainting model of \cite{Dong2013X} and…

Medical Physics · Physics 2016-01-27 Ruohan Zhan , Bin Dong

At the present time Optical Coherence Tomography (OCT) is among the most commonly used non-invasive imaging methods for the acquisition of large volumetric scans of human retinal tissues and vasculature. To resolve decisive information from…

Computer Vision and Pattern Recognition · Computer Science 2021-11-02 D. Sitenko , B. Boll , C. Schnörr

We propose a model-based image reconstruction method for photoacoustic tomography(PAT) involving a novel form of regularization and demonstrate its ability to recover good quality images from significantly reduced size datasets. The…

Image and Video Processing · Electrical Eng. & Systems 2020-12-29 Nadaparambil Aravindakshan Rejesh , Sandeep Kumar Kalva , Manojit Pramanik , Muthuvel Arigovindan

Photoacoustic tomography is a hybrid imaging technique that combines high optical tissue contrast with high ultrasound resolution. Direct reconstruction methods such as filtered backprojection, time reversal and least squares suffer from…

Performing X-ray computed tomography (CT) examinations with less radiation has recently received increasing interest: in medical imaging this means less (potentially harmful) radiation for the patient; in non-destructive testing of…

Medical Physics · Physics 2018-09-25 Dragos Trinca , Eduard Libin

Intrinsic optical signal (IOS) imaging of the retina, also termed as optoretinography (ORG), promises a noninvasive method for objective assessment of retinal function. By providing unparalleled capability to differentiate individual layers…

Medical Physics · Physics 2022-02-22 Tae-Hoon Kim , Guangying Ma , Taeyoon Son , Xincheng Yao

In optical tomography a physical body is illuminated with near-infrared light and the resulting outward photon flux is measured at the object boundary. The goal is to reconstruct internal optical properties of the body, such as absorption…

Numerical Analysis · Mathematics 2016-01-20 Antti Hannukainen , Lauri Harhanen , Nuutti Hyvönen , Helle Majander

Imaging airway tissue, optical coherence tomography (OCT) provides cross-sectional images of tissue structures, shows cilia movement and mucus secretion, but does not provide sufficient contrast to differentiate individual cells. By using…

The recent development of scintillation crystals combined with $\gamma$-rays sources opens the way to an imaging concept based on Compton scattering, namely Compton scattering tomography (CST). The associated inverse problem rises many…

Numerical Analysis · Mathematics 2023-02-22 Janek Gödeke , Gaël Rigaud

Optical Coherence Tomography (OCT) has become one of the most used imaging modality in ophthalmology. It provides high-resolution, non-invasive visualization of retinal microarchitecture. The automated analysis of OCT images through…

Computer Vision and Pattern Recognition · Computer Science 2026-05-05 Hedi Tabia , Désiré Sidibé , Nawres Khlifa , Ahmed Tabia , Ines Rahmany , Noura Aboudi , Zainab Haddad , Hajer Khachnaoui , Hsouna Zgolli

We propose a novel intensity diffraction tomography (IDT) reconstruction algorithm based on the split-step non-paraxial (SSNP) model for recovering the 3D refractive index (RI) distribution of multiple-scattering biological samples.…

Optics · Physics 2022-09-09 Jiabei Zhu , Hao Wang , Lei Tian

In ultrasound nondestructive testing, a widespread approach is to take synthetic aperture measurements from the surface of a specimen to detect and locate defects within it. Based on these measurements, imaging is usually performed using…

Signal Processing · Electrical Eng. & Systems 2020-12-09 Jan Kirchhof , Sebastian Semper , Christoph W. Wagner , Eduardo Pérez , Florian Römer , Giovanni Del Galdo
‹ Prev 1 8 9 10 Next ›