English
Related papers

Related papers: A test platform for the detection and readout chai…

200 papers

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually…

Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/\Delta…

Instrumentation and Methods for Astrophysics · Physics 2022-09-14 H. Akamatsu , W. B. Doriese , J. A. B. Mates , B. D. Jackson

For cosmic particle spectroscopy on the International Space Station the AMS experiment will be equipped with a Transition Radiation Detector (TRD) to improve particle identification. The TRD has 20 layers of fleece radiator with Xe/CO2…

Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…

Instrumentation and Detectors · Physics 2026-04-29 Jodok Zeuner , Constantin Schuster , Sebastian Kempf

The detector readout architecture introduced in this paper is intended for small to medium size physics experiments that have moderate bandwidth needs, and applications that require an ultimately low background radioactivity for the parts…

Signal Processing · Electrical Eng. & Systems 2018-06-21 Denis Calvet

Detectors for direct dark matter search using noble gases in liquid phase as detection medium need to be coupled to liquefaction, purification and recirculation systems. A dedicated cryogenic system has been assembled and operated at the…

Instrumentation and Detectors · Physics 2023-03-29 G. Grauso , A. Basco , N. Canci , R. de Asmundis , F. Di Capua , G. Matteucci , Y. Suvorov , G. Fiorillo

We report experimental demonstration of the feasibility of reaching temperatures below 1 mK using cryogen-free technology. Our prototype system comprises an adiabatic nuclear demagnetisation stage, based on hyperfine-enhanced nuclear…

Instrumentation and Detectors · Physics 2015-06-16 Graham Batey , Andrew Casey , Michael Cuthbert , Anthony Matthews , John Saunders , Aya Shibahara

The CONCERTO spectral-imaging instrument was installed at the Atacama Pathfinder EXperiment (APEX) 12-meter telescope in April 2021. It has been designed to look at radiation emitted by ionised carbon atoms, [CII], and use the "intensity…

A Transition Radiation Detector (TRD) has been designed to improve the electron identification and trigger capability of the ALICE experiment at the Large Hadron Collider (LHC) at CERN. We present results from tests of a prototype of the…

X-ray calorimetric sample platforms combining specific heat and synchrotron x-ray measurements provide a powerful means to investigate fundamental material properties. Calorimeter cell designs featuring a compact heater and thermometer…

Instrumentation and Detectors · Physics 2026-02-02 U. Patel , H. Zheng , J. L. McChesney , U. Welp , Z. Islam , A. Miceli

i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,\gamma$) cross-section measurements using time-of-flight technique. This work presents the first…

Instrumentation and Detectors · Physics 2024-10-17 V. Babiano-Suárez , J. Lerendegui-Marco , J. Balibrea-Correa , L. Caballero , D. Calvo , I. Ladarescu , C. Domingo-Pardo , F. Calviño , A. Casanovas , A. Tarifeño-Saldivia , V. Alcayne , C. Guerrero , M. A. Millán-Callado , M. T. Rodríguez González , M. Barbagallo , O. Aberle , S. Amaducci , J. Andrzejewski , L. Audouin , M. Bacak , S. Bennett , E. Berthoumieux , J. Billowes , D. Bosnar , A. Brown , M. Busso , M. Caamaño , M. Calviani , D. Cano-Ott , F. Cerutti , E. Chiaveri , N. Colonna , G. Cortés , M. A. Cortés-Giraldo , L. Cosentino , S. Cristallo , L. A. Damone , P. J. Davies , M. Diakaki , M. Dietz , R. Dressler , Q. Ducasse , E. Dupont , I. Durán , Z. Eleme , B. Fern\' , ez-Domínguez , A. Ferrari , P. Finocchiaro , V. Furman , K. Göbel , R. Garg , A. Gawlik , S. Gilardoni , I. F. Gonçalves , E. González-Romero , F. Gunsing , H. Harada , S. Heinitz , J. Heyse , D. G. Jenkins , A. Junghans , F. Käppeler , Y. Kadi , A. Kimura , I. Knapova , M. Kokkoris , Y. Kopatch , M. Krtička , D. Kurtulgil , C. Lederer-Woods , H. Leeb , S. J. Lonsdale , D. Macina , A. Manna , T. Martinez , A. Masi , C. Massimi , P. Mastinu , M. Mastromarco , E. A. Maugeri , A. Mazzone , E. Mendoza , A. Mengoni , V. Michalopoulou , P. M. Milazzo , F. Mingrone , J. Moreno-Soto , A. Musumarra , A. Negret , F. Ogállar , A. Oprea , N. Patronis , A. Pavlik , J. Perkowski , L. Persanti , C. Petrone , E. Pirovano , I. Porras , J. Praena , J. M. Quesada , D. Ramos-Doval , T. Rauscher , R. Reifarth , D. Rochman , C. Rubbia , M. Sabaté-Gilarte , A. Saxena , P. Schillebeeckx , D. Schumann , A. Sekhar , A. G. Smith , N. V. Sosnin , P. Sprung , A. Stamatopoulos , G. Tagliente , J. L. Tain , L. Tassan-Got , Th. Thomas , P. Torres-Sánchez , A. Tsinganis , J. Ulrich , S. Urlass , S. Valenta , G. Vannini , V. Variale , P. Vaz , A. Ventura , D. Vescovi , V. Vlachoudis , R. Vlastou , A. Wallner , P. J. Woods , T. Wright , P. Žugec

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting…

Instrumentation and Detectors · Physics 2018-01-23 nEXO Collaboration , M. Jewell , A. Schubert , W. R. Cen , J. Dalmasson , R. DeVoe , L. Fabris , G. Gratta , A. Jamil , G. Li , A. Odian , M. Patel , A. Pocar , D. Qiu , Q. Wang , L. J. Wen , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. Barbeau , D. Beck , V. Belov , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , G. F. Cao , L. Cao , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , A. Craycraft , W. Cree , M. Côté , T. Daniels , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , T. Didberidze , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , W. Fairbank , J. Farine , S. Feyzbakhsh , R. Fontaine , D. Fudenberg , G. Giacomini , R. Gornea , E. V. Hansen , D. Harris , M. Hasan , M. Heffner , E. W. Hoppe , A. House , P. Hufschmidt , M. Hughes , J. Hößl , Y. Ito , A. Iverson , X. S. Jiang , S. Johnston , A. Karelin , L. J. Kaufman , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , D. S. Leonard , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , B. Mong , D. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , K. Odgers , M. Oriunno , J. L. Orrell , I. Ostrovskiy , C. T. Overman , G. S. Ortega , S. Parent , A. Piepke , J. -F. Pratte , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retiere , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , D. Sinclair , K. Skarpaas , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , X. L. Sun , M. Tarka , J. Todd , T. Tolba , R. Tsang , T. Tsang , F. Vachon , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , M. Wagenpfeil , M. Weber , W. Wei , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Z. Xuan , L. Yang , D. Yayun , Y. -R. Yen , O. Zeldovich , X. Zhang , J. Zhao , N. Zhe , Y. Zhou , T. Ziegler

The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take…

We report on the development of the thallium-doped cesium iodide (CsI:Tl) calorimeter subsystem for the All-Sky Medium-Energy Gamma-ray Observatory (AMEGO) [1]. The CsI:Tl calorimeter is one of the three main subsystems that comprise the…

Instrumentation and Detectors · Physics 2019-01-18 Richard S. Woolf , J. Eric Grove , Bernard F. Phlips , Eric A. Wulf

The PANCAKE facility is the world's largest liquid xenon test platform. Inside its cryostat with an internal diameter of 2.75 m, components for the next generation of liquid xenon experiments, such as DARWIN or XLZD, will be tested at their…

The Athena+ X-ray mirror will provide a collecting area of 2 m^2 at 1 keV and an angular resolution of 5 arc seconds Half Energy Width. The manufacture and performance of this mirror is of paramount importance to the success of the mission.…

Instrumentation and Methods for Astrophysics · Physics 2013-07-09 Richard Willingale , Giovanni Pareschi , Finn Christensen , Jan-Willem den Herder

Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high…

Instrumentation and Detectors · Physics 2024-10-28 Ting Wang , Yu Wang , Zhihang Yao , Yulin Liu , Changqing Feng , Zhiyong Zhang , Shubin Liu

This paper reports on the methods and results of a theoretical analysis to design an insulator which must provide a thermally quiet environment to test on ground delicate temperature sensors and associated electronics. These will fly on…

General Relativity and Quantum Cosmology · Physics 2007-05-23 Alberto Lobo , Miquel Nofrarias , Juan Ramos-Castro , Josep Sanjuan

Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the…