Related papers: A Precise Method to Determine the Energy Scale and…
Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit…
In light of the recent finding of the narrow clustering of the geometrically-corrected gamma-ray energies emitted by Gamma Ray Bursts (GRBs), we investigate the possibility to use these sources as standard candles to probe cosmological…
This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile…
We describe the design and construction of the low rate neutron calibration sources used in the Daya Bay Reactor Anti-neutrino Experiment. Such sources are free of correlated gamma-neutron emission, which is essential in minimizing induced…
Different determinations currently suggest scattered values for the power spectrum normalization on the scale of galaxy clusters, sigma_8. Here we concentrate on the constraints coming from the X-ray temperature and luminosity functions…
The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever…
The results of calibration by cosmic muons of a shower lead-scintillation spectrometer of the sandwich type designed to work in high-intensity photon and electron beams with an energy of 0.1 - 1.0 GeV are presented. It was found that the…
We measure and explain scintillator non-proportionality and gamma quenching of CaWO4 at low energies and low temperatures. Phonons that are created following an interaction in the scintillating crystal at temperatures of 15mK are used for a…
The Large Area Telescope (LAT) onboard the Fermi satellite is exploring the gamma-ray sky in the energy range above 20MeV. We have developed a method to reconstruct the energy spectra of the gamma rays detected by the Fermi LAT instrument…
Fluctuations in photon production in scintillator could contribute to the total energy resolution of a scintillation detector. This contribution, called intrinsic resolution (IR), is one of the factors limiting the total energy resolution…
We estimate \Delta Gamma_d/\Gamma_d, including 1/m_b contributions and part of the next-to-leading order QCD corrections, and find it to be around 0.3%. We show the methods to measure \Delta Gamma_d/\Gamma_d by using at least two different…
A white light vortex coronagraph was used to experimentally achieve sub-resolution detection. The angular location of the centroid, $\gamma$, and the angular extent of circular pinhole sources, $\Theta$, were measured to within errors of…
The scope of this article is to understand the role of radiative losses in detector energy scale at energies of 5-100 MeV and to estimate the non-linear effect they produce in large liquid scintillator and Cherenkov detectors. For this…
In order to cope with increasing lifetime radiation damage expected at collider experiments, silicon sensors are becoming increasingly thin. To achieve adequate detection efficiency, the next generation of detectors may have to operate with…
Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can be exploited to achieve an outstanding…
In Charge Coupled Device (CCD) detectors the electrons excited upon absorption of a single x-ray photon quickly diffuse and generate charge-spots often larger than pixel dimensions. In the soft x-ray range this phenomenon drastically limits…
A novel method for localization and estimation of compact sources of gamma radiation for Micro Aerial Vehicles (MAVs) is presented in this paper. The method is developed for a novel single-detector Compton camera, developed by the authors.…
Accurate quantitative mapping of gamma-ray sources is critical for applications ranging from radiological emergency response and environmental monitoring to nuclear security and deep space exploration. Here, we show that integrating…
We measure the mass difference, \Delta m_0, between the D*(2010)+ and the D0 and the natural line width, \Gamma, of the transition D*(2010)+ -> D0 pi+. The data were recorded with the BABAR detector at center-of-mass energies at and near…
A flexible apparatus for calibration of the absolute flux at the focal plane of the X-ray Source of a Powder Diffractometer, based on a fast scintillator counter, is presented. The measured fluxes, depending on the high voltage on the X-ray…