Related papers: A Precise Method to Determine the Energy Scale and…
Scintillating calorimeters are cryogenic detectors combining a measurement of scintillation with one of phonons to provide particle identification. In view of developing alkali halide devices of this type able to check the DAMA/LIBRA claim…
Plasma scattering measurement is effective technique to observe low frequency density fluctuations excited in plasma. The spatial and wave number resolutions and the S/N ratio of measurement depend on the wavelength range, the size and the…
In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption…
Radiation detectors deployed as part of a large urban network or for homeland security monitoring must maintain reliable energy calibration even when subjected to substantial variations in temperature and ambient background radiation.…
Detectors based on liquid or gas xenon have been used and are in use for a number of applications, in particular for the detection of gamma rays. Xenon is a well-suited medium for gamma spectroscopy thanks to its high atomic number and,…
Chromatic calorimetry (CCAL) analyses particle detection by utilizing scintillators with distinct emission wavelengths to measure the longitudinal energy deposition of particle showers in high-energy physics, improving particle…
This work presents a study on the fundamental aspects of a reliable gold determination in voluminous mineral samples by Neutron Activation Analysis, using a Linear Particle Accelerator as a source of irradiation and a single detector as a…
At present, a two-phase argon detector is being developed in our laboratory for dark matter search and low-energy neutrino experiments. To calibrate its energy scale a $^{109}$Cd gamma-ray source was used. In this work a detailed emission…
Measuring the centroid of a spectral line is a common problem in astronomy. Many methods have been devised to overcome limitations due to either noise in the spectra or asymmetric profiles, the most common of which are the intensity…
This paper studies the possibility to measure the centre of mass energy using e+e- -> Z,gamma -> mu+mu-,gamma events at the ILC. With L = 100 fb^-1 at sqrt(s) = 350 GeV a relative error of around 10^{-4} is possible. The potentially largest…
Novel methods to reconstruct the slant depth of the maximum of the longitudinal profile (\Xmax) of high-energy showers initiated by gamma-rays as well as their energy ($E_0$) are presented. The methods were developed for gamma rays with…
We constructed a gamma-ray detector by combining two types of scintillator array detectors with an MPPC array and evaluated the spectral performance by reading out the signals from the MPPC with a low-power integrated circuit (ASIC)…
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The…
A simulation study of energy resolution, position resolution, and $\pi^0$-$\gamma$ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the…
This work developed an accurate and robust absorption-based method for spatially resolved measurements of gas temperatures in flames and reacting flows, with typical single-measurement uncertainties on the order of 1\%. This method exploits…
In a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, energy resolution is important to distinguish between $0\nu\beta\beta$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy…
The GERmanium Detector Array, GERDA, searches for neutrinoless double beta decay in Ge-76 using bare high-purity germanium detectors submerged in liquid argon. For the calibration of these detectors gamma emitting sources have to be lowered…
Localisation of gamma-ray interaction points in monolithic scintillator crystals can simplify the design and improve the performance of a future Compton telescope for gamma-ray astronomy. In this paper we compare the position resolution of…
Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…