Related papers: Towards low gas consumption of muographic tracking…
In some experiments and applications there is need for large-area photosensitive detectors to operate at cryogenic temperatures. Nowadays, vacuum PMs are usually used for this purpose. We have developed special designs of planar…
We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of…
Muography is an imaging tool based on the attenuation of cosmic muons to observe the density distribution of large objects, such as underground caves or fractured zones. Tomography based on muography measurements -- that is, three…
The Inner Tracker System of the HERA-B experiment at DESY consists of 184 Microstrip Gas Chambers (MSGC) with a total number of 147 456 electronic read out channels. The detectors have to cope with particle fluxes up to 25 kHz/mm**2 and to…
A quality assurance and performance qualification laboratory was built at McGill University for the Canadian-made small-strip Thin Gap Chamber (sTGC) muon detectors produced for the 2019-2020 ATLAS experiment muon spectrometer upgrade. The…
A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…
A novel methodology for measuring gas flow from small orifices or nozzles into vacuum is presented. It utilizes a high-intensity femtosecond laser pulse to create a plasma within the gas plume produced by the nozzle, which is imaged by a…
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August…
A Resistive Plate Chamber using Diamond-Like Carbon electrodes (DLC-RPC) has been developed as a background tagging detector in the MEG$~$II experiment. The DLC-RPC is planned to be installed in a high-intensity and low-momentum muon beam.…
Measurements at 100 TeV and above are an important goal for the next generation of high energy gamma-ray astronomy experiments to solve the still open problem of the origin of galactic cosmic rays. The most natural experimental solution to…
Open-path Tunable Diode Laser Absorption Spectroscopy offers an effective method for measuring, mapping, and monitoring gas concentrations, such as leaking CO2 or methane. Compared to spatial sampling of gas distributions using in-situ…
For MWPC used for X-ray position detection, simulation study of the anode wire modulation effect of the detector was carried out with Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain…
The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$…
A high spatial resolution tracking system was setup with the Micro-mesh gaseous structure (Micromegas) detectors in order to study the muon tomographic imaging technique for nuclear threat detection. 6 layers of 90 mm $\times$ 90 mm…
Searches of new physics beyond the Standard Model (SM) performed at low energy frontiers are complementary to experiments carried out at high energy colliders. Among the methods for testing the SM and beyond at low energies are the…
As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC…
We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an…
Results from the gas gain monitoring (GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented. The system is designed to provide fast and accurate determination of any shift in the working point of the…
Recent applications of cosmic-ray muons require accurate modeling of their flux at low-energy. However, no measurement has been reported below 400 MeV. Therefore, we developed a full-absorption muon energy spectrometer to obtain energy…
The magnetized MINOS Near Detector, at a depth of 225 meters of water equivalent (mwe), is used to measure the atmospheric muon charge ratio. The ratio of observed positive to negative atmospheric muon rates, using 301 days of data, is…