English
Related papers

Related papers: High-performance, compact optical standard

200 papers

We report on the realization of a new compact strontium optical clock using a 2-D magneto-optical-trap (2D-MOT) as cold atomic source and a multi-wavelength cavity as the frequency stabilization system. All needed optical frequencies are…

Atomic Physics · Physics 2022-04-29 Matteo Barbiero , Davide Calonico , Filippo Levi , Marco G. Tarallo

We present a new type of dual optical frequency comb source capable of scaling applications to high measurement speeds while combining high average power, ultra-low noise operation, and a compact setup. Our approach is based on a…

Optical sound pressure measurement is a promising technology to establish primary acoustic standards without reliance on specific types of microphones. We developed a precision optical sound pressure measurement system by combining a…

Instrumentation and Detectors · Physics 2025-12-22 Koto Hirano , Wataru Kokuyama , Hajime Inaba , Sho Okubo , Tomofumi Shimoda , Hironobu Takahashi , Keisuke Yamada , Hideaki Nozato

Ultra-stable lasers and optical frequency combs have been the enabling technologies for the tremendous progress of precise optical spectroscopy in the last ten years. To improve laser frequency stabilization beyond the thermal-noise…

We have demonstrated the possibility for a compact frequency standard based on a sample of cold cesium atoms. In a cylindrical microwave cavity, the atoms are cooled and interrogated during a free expansion and then detected. The operation…

We developed a novel technique for frequency measurement and synthesis, based on the operation of a femtosecond comb generator as transfer oscillator. The technique can be used to measure frequency ratios of any optical signals throughout…

Optics · Physics 2009-11-07 Jörn Stenger , Harald Schnatz , Christian Tamm , Harald R. Telle

We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The…

In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the…

Highly frequency-stable lasers are a ubiquitous tool for optical frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for…

We demonstrate the long-distance transmission of an ultra-stable optical frequency derived directly from a state-of-the-art optical frequency standard. Using an active stabilization system we deliver the frequency via a 146 km long…

Optics · Physics 2016-04-13 G. Grosche , O. Terra , K. Predehl , R. Holzwarth , B. Lipphardt , F. Vogt , U. Sterr , H. Schnatz

We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical…

We report on the development and performance evaluation of an ultra-stable clock laser for an $\rm ^{27}Al^+$ optical clock. The thermal noise limited ultra-stable laser is developed based on a 30 cm long ultra-stable cavity. Three…

Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and…

Robust control and stabilization of optical frequency combs enables an extraordinary range of scientific and technological applications, including frequency metrology at extreme levels of precision, novel spectroscopy of quantum gases and…

Optics · Physics 2013-08-09 Scott B. Papp , Pascal Del'Haye , Scott A. Diddams

Frequency stabilisation of lasers to optical reference cavities is an established method to achieve state-of-the-art stability. The strengths of this method are the high discriminator coefficient of optical cavities, and the low-noise…

Optics · Physics 2025-04-28 Adam L. Parke , Marco Schioppo

State-of-the-art laser frequency stabilization is limited by miniscule length changes caused by thermal noise. In this work, a cavity-length-insensitive frequency stabilization scheme is implemented using strong dispersion in a…

The interrogation of an ultra-narrow clock transition of a single trapped ion for optical frequency metrology requires a laser stabilized to a couple of Hz per second with a linewidth of the same order of magnitude. Today, lasers in the…

Optics · Physics 2015-05-14 Didier Guyomarc'H , Gaëtan Hagel , Cédric Zumsteg , Martina Knoop

For the optical generation of ultrastable microwave signals for fountain clocks we developed a setup, which is based on a cavity stabilized laser and a commercial frequency comb. The robust system, in operation since 2020, is locked to a…

Atomic Physics · Physics 2023-10-09 Burghard Lipphardt , Patrick Walkemeyer , Michael Kazda , Johannes Rahm , Stefan Weyers

We present the characterization of a laser frequency stabilization scheme using a state-of-the-art wavelength meter based on solid Fizeau interferometers. For a frequency-doubled Ti-sapphire laser operated at 461 nm, an absolute Allan…

Instrumentation and Detectors · Physics 2018-05-09 Luc Couturier , Ingo Nosske , Fachao Hu , Canzhu Tan , Chang Qiao , Y. H. Jiang , Peng Chen , Matthias Weidemüller

We report on an ultralow noise optical frequency transfer from a remotely located Sr optical lattice clock laser to a Ti:Sapphire optical frequency comb through telecom-wavelength optical fiber networks. The inherent narrow linewidth of the…

Instrumentation and Detectors · Physics 2019-06-26 Eunmi Chae , Kota Nakashima , Takuya Ikeda , Kei Sugiyama , Kosuke Yoshioka
‹ Prev 1 3 4 5 6 7 10 Next ›