Related papers: Characterization of Tl$_2$NaYCl$_6$:Ce Scintillati…
In this paper we report the experimental study of high-pressure xenon used as a scintillator, in the context of developing a gamma ray detector. We measure a light yield near 2 photoelectrons per keV for xenon at 40 bar. Together with the…
We report a study of CsI(Tl) scintillator to assess its applicability in experiments to search for dark matter particles. Measurements of the mean scintillation pulse shapes due to nuclear and electron recoils have been performed. We find…
First observation of liquid xenon scintillation due to alpha-particles and gamma-rays with a large area avalanche photodiode immersed in the liquid is reported. An energy resolution of 10% (FWHM) and a coincidence time resolution of less…
Scintillation crystals are commonly used for direct detection of weakly interacting massive particles (WIMPs), which are suitable candidates for a particle dark matter. It is well known that the scintillation light yields are different for…
The optical and scintillation properties of undoped, Si-doped, and Si, B co-doped GaAs samples were studied. The light yield specification and X-ray luminescence of GaAs over a wide IR region by using Si and InGaAs photodetectors are…
The measurement of the 2D-Angular Correlation of Electron Positron Annihilation Radiation (ACAR) provides unique information about the bulk electronic structure of single crystals. We set up a new prototype for 2D-ACAR measurements using…
Scintillating crystal detector may offer some potential advantages in the low-energy, low-background experiments. A 500 kg CsI(Tl) detector to be placed near the core of Nuclear Power Station II in Taiwan is being constructed for the…
GaAs devices have relatively high atomic numbers (Z=31, 33) and thus extend the X-ray absorption edge beyond that of Si (Z=14) devices. In this study, radiation detectors were processed on GaAs substrates with 110 $\mu\textrm{m}$ - 130…
Research in ceramic scintillators has steadily progressed alongside the research in bulk single crystal scintillator growth. As interest in faster scintillation material production with lower cost increases, more research on scintillating…
The first domestic inorganic scintillator CLYC was grown in Beijing Glass Research Instituteusing the vertical Bridgman method. In this work, we evaluated the performance of this new CLYC crystal in terms of gamma-ray energy resolution and…
Fast neutrons are a large background to measurements of gamma-rays emitted from excited nuclei, such that detectors which can efficiently distinguish between the two are essential. In this paper we describe the separation of gamma-rays from…
A Scintillator Deposited CCD (SDCCD) is a wide-band X-ray detector consisting of a CCD and a scintillator directly attached to each other. We assembled the newly developed SDCCD that the scintillator CsI(Tl) is below the fully depleted CCD.…
Scintillating NaI(Tl) crystals are used for various rare decay experiments, such as dark matter searches. The hygroscopicity of NaI(Tl) crystal makes the construction of crystal detectors in these experiments challenging and requires a…
Searches for weakly interacting massive particles(WIMP) can be based on the dete ction of nuclear recoil energy in CsI(Tl) crystals. We demonstrate that low energy gamma rays down to few keV is detected with CsI(Tl) crystal detector. A…
Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a…
Experimental and theoretical studies of spectral properties of crystalline TlCl:Bi are performed. Two broad near-infrared luminescence bands with a lifetime about 0.25 ms are observed: a strong band near 1.18 mkm excited by 0.40, 0.45, 0.70…
Localisation of gamma-ray interaction points in monolithic scintillator crystals can simplify the design and improve the performance of a future Compton telescope for gamma-ray astronomy. In this paper we compare the position resolution of…
The light output of the 324 CsI(Tl) scintillators of INDRA has been measured over a large range both in energy: 1 - 80 AMeV and in atomic number of incident ions: Z = 1 - 60. An analytical expression for the nonlinear total light response…
A compact gamma-ray detector module was developed and characterized for spectroscopic applications across a wide energy range. The detector comprises a 4x4 array of silicon photomultipliers (SiPMs, Hamamatsu MPPC S13360-3050) coupled with…
This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment.…