Many advanced techniques have been developed, tested and implemented in the last decades in almost all circular accelerators across the world to measure the linear optics. However, the greater availability and accuracy of beam diagnostics…

Accelerator Physics · Physics 2018-04-18 Andrea Franchi

The primary objective of accelerator tuning is to correct its linear optics. This involves adjusting a large set of parameters, such as quadrupole lens gradients and alignment errors, as well as addressing various calibration errors in beam…

Accelerator Physics · Physics 2023-12-05 I. Morozov , Yu. Maltseva

In the present work we develop an algorithm for calibrating MEMS sensors, which accounts for the nonorthogonality of the accelerometers' axis, as well as for the constant bias and scaling errors. We derive an explicit formula for computing…

Other Computer Science · Computer Science 2013-09-20 Svetoslav Nakov , Tihomir Ivanov

A high-accuracy calibration of inductive coil sensors based on Printed Circuit Board (PCB), commonly used in rotating coil field measurements of particle accelerator magnets, is presented. The amplitude and phase of signals with and without…

Accelerator Physics · Physics 2019-03-04 Joseph DiMarco , Giordana Severino , Pasquale Arpaia

Corrections of gradient errors in the interactions regions (IRs) of high energy colliders have traditionally been made by changing the strengths of quadrupoles that are common to both beams, such as the triplet quadrupoles. This article…

Accelerator Physics · Physics 2020-02-17 Javier Fernando Cardona , Yohany Rodríguez , Rogelio Tomás

We investigate methods to calibrate the non-common path aberrations at an adaptive optics system having a wavefront-correcting device working at an extremely high resolution (larger than 150x150). We use focal-plane images collected…

Instrumentation and Methods for Astrophysics · Physics 2015-06-22 Visa Korkiakoski , Christoph U. Keller , Niek Doelman , Matthew Kenworthy , Gilles Otten , Michel Verhaegen

Visual navigation devices require precise calibration to achieve high-precision localization and navigation, which includes camera and attitude calibration. To address the limitations of time-consuming camera calibration and complex…

Computer Vision and Pattern Recognition · Computer Science 2025-02-26 Shunkun Liang , Dongcai Tan , Banglei Guan , Zhang Li , Guangcheng Dai , Nianpeng Pan , Liang Shen , Yang Shang , Qifeng Yu

A compact beam-profile monitor was constructed using a linear contact image sensor attached to a plastic scintillator and tested using a 230 MeV proton beam. The results indicate that the beam distribution can be obtained in real-time, and…

Medical Physics · Physics 2019-12-23 Tung-Yuan Hsiao , Tzung-Yuang Chen , Huan Niu , Chien-Hsu Chen

Beam position monitor (BPM) can easily reinforce the handling of beam orbits and measure the absolute beam position [1]. Its data can be used to optimize and correct beam in both first turn and closed orbit mode. In order to set the…

Accelerator Physics · Physics 2019-08-17 Jiandong Yuan , Lizhen Ma , Bin Zhang , Junjie Yao

A fully digital beam position and phase measurement (BPPM) system was designed for the linear accelerator (LINAC) in Accelerator Driven Sub-critical System (ADS) in China. Phase information is obtained from the summed signals from four…

Instrumentation and Detectors · Physics 2019-09-25 Xingshun Gao , Lei Zhao , Jinxin Liu , Zouyi Jiang , Xiaofang Hu , Shubin Liu , Qi An

The beam aperture of a particle accelerator defines the clearance available for the circulating beams and is a parameter of paramount importance for the accelerator performance. At the CERN Large Hadron Collider (LHC), the knowledge and…

The main task of an energy calibration is to find a relation between pulse-height values and the corresponding energies. Doing this for each pulse-height channel individually requires an elaborated input spectrum with an excellent counting…

Instrumentation and Detectors · Physics 2016-02-17 Daniel Maier , Olivier Limousin

In the Large Hadron Collider, the beam losses are continuously measured for machine protection. By design, most of the particle losses occur in the collimation system, where the particles with high oscillation amplitudes or large momentum…

Accelerator Physics · Physics 2023-01-11 Ekaterina Krymova , Guillaume Obozinski , Michael Schenk , Loic Coyle , Tatiana Pieloni

Low-cost micro-electromechanical accelerometers are widely used in navigation, robotics, and consumer devices for motion sensing and position estimation. However, their performance is often degraded by bias errors. To eliminate…

Robotics · Computer Science 2025-11-18 Michal Levin , Itzik Klein

The energy calibration of calorimeters at collider experiments, such as the ones at the CERN Large Hadron Collider, is crucial for achieving the experiments physics objectives. Standard calibration approaches have limitations that become…

Good geometrical calibration is essential in the use of high resolution detectors. The individual sensors in the detector have to be calibrated with an accuracy better than the intrinsic resolution, which typically is of the order of 10 um.…

Data Analysis, Statistics and Probability · Physics 2009-09-29 V. Karimaki , A. Heikkinen , T. Lampen , T. Linden

In conventional beam based alignment (BBA) procedures, the relative alignment of a quadrupole to a nearby beam position monitor is determined by finding a beam position in the quadrupole at which the closed orbit does not change when the…

High Energy Physics - Experiment · Physics 2010-11-15 G. H. Hoffstaetter , F. Willeke

The problem of errors, arising due to finite BPM resolution, in the difference orbit parameters, which are found as a least squares fit to the BPM data, is one of the standard and important problems of accelerator physics. Even so for the…

Accelerator Physics · Physics 2010-02-23 V. Balandin , W. Decking , N. Golubeva

Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the…

Instrumentation and Detectors · Physics 2023-03-07 Mayank Goswami , Kajal Kumari

The paper focuses on the accuracy improvement of geometric and elasto-static calibration of industrial robots. It proposes industry-oriented performance measures for the calibration experiment design. They are based on the concept of…

Robotics · Computer Science 2012-11-27 Yier Wu , Alexandr Klimchik , Anatol Pashkevich , Stéphane Caro , Benoît Furet