Detailed knowledge of particle-beam properties is of great importance to understand and push the performance of existing and next-generation particle accelerators. We recently proposed a new phase-space tomography method to reconstruct the…
In a scanning transmission electron microscope (STEM), producing a high-resolution image generally requires an electron beam focused to the smallest point possible. However, the magnetic lenses used to focus the beam are unavoidably…
Fast wire scanners are today considered as part of standard instrumentation in high energy synchrotrons. The extension of their use to synchrotrons working at lower energies, where Coulomb scattering can be important and the transverse beam…
Instruments to visualize transient structural changes of inhomogeneous materials on the nanometer scale with atomic spatial and temporal resolution are demanded to advance materials science, bioscience, and fusion sciences. One such…
Beam shaping - the ability to engineer the phase and the amplitude of massive and massless particles - has long interested scientists working on communication, imaging and the foundations of quantum mechanics. In light optics, the shaping…
Dielectric tensor tomography is an imaging technique for mapping three-dimensional distributions of dielectric properties in transparent materials. This work introduces an enhanced illumination strategy employing a micro-electromechanical…
Recent studies have demonstrated the possibility of accelerating electrons to MeV energies in ambient air using tightly focused laser configurations. In this article, we explore possible strategies to control and optimize the resulting…
A modified electron beam induced deposition method using a parallel beam of electrons is developed. The method relies on the build-up of surface potential on an insulating surface exposed to an electron beam. Presence of sharp edges on the…
We conduct a detailed measurement and analysis of a hadron beam in five-dimensional phase space at the Spallation Neutron Source Beam Test Facility. The measurement's resolution and dynamic range are sufficient to image sharp,…
Strain engineering is used to obtain desirable materials properties in a range of modern technologies. Direct nanoscale measurement of the three-dimensional strain tensor field within these materials has however been limited by a lack of…
The control of beam phase relative to the accelerating RF field within a superconducting cavity is important in many accelerator applications and is of particular importance for a free electron laser facility. As standard practice, the…
Nanofabrication techniques for achieving dimensional control at the nanometer scale are generally equipment-intensive and time-consuming. The use of energetic beams of electrons or ions has placed the fabrication of nanopores in thin…
In TEM, a typical goal consists of making a small electron probe in the sample plane in order to obtain high spatial resolution in scanning transmission electron microscopy. In order to do so, the phase of the electron wave is corrected to…
A common issue encountered in photoemission electron sources used in electron accelerators is distortion of the laser spot due to non ideal conditions at all stages of the amplification. Such a laser spot at the cathode may produce…
Leveraging the full scientific capabilities of next-generation high-repetition-rate free-electron lasers requires programmable control over electron-beam properties at their source. The photoinjector drive laser defines the electron beam's…
The wavefront measurement of a light beam is a complex task, which often requires a series of spatially resolved intensity measurements. For instance, a detector array may be used to measure the local phase gradient in the transverse plane…
Programmable electron-beam scanning offers new opportunities to improve dose efficiency and suppress scan-induced artifacts in scanning transmission electron microscopy. Here, we systematically benchmark the impact of non-raster…
By scanning a fine open-ended coaxial probe above an operating microwave device, we image local electric fields generated by the device at microwave frequencies. The probe is sensitive to the electric flux normal to the face of its center…
High-quality and prebunched electron beams can produce coherent x-rays with high intensity and narrow bandwidth, which is essential for modern light sources. An all-optical scheme based on plasma-based acceleration to produce bright…
A novel device that can be used as a tunable support-free phase plate for transmission electron microscopy of weakly scattering specimens is described. The device relies on the generation of a controlled phase shift by the magnetic field of…