English
Related papers

Related papers: A Novel Antimicrobial Electrochemical Glucose Bios…

200 papers

Nanostructured transition metal oxides (TMO) are extensively explored materials for non-enzymatic glucose sensors. TMOs such as Iron oxides( {\alpha}-Fe2O3, {\gamma}-Fe2O3, Fe3O4, etc.), NiO, CuO, Cr2O3, etc. have been utilized as…

Materials Science · Physics 2026-01-27 Piyush Choudhary , Chhavi Chetiwal , Chandra Prakash , Vijay K. Singh , Ambesh Dixit

Fabrication of a highly sensitive non-enzymatic electrochemical sensor for the detection of cholesterol is a challenging issue due to its low redox activity. In the present study, the electrochemical response of a novel combination of metal…

Instrumentation and Detectors · Physics 2022-09-28 Zahra Gholami Shiri , Seyed Mojtaba Zebarjad , Kamal Janghorban

A novel mediator-free, non-enzymatic electrochemical sensor, based on a graphene-Schottky junction, was fabricated for glucose detection. The sensor offers a promising alternative to the conventional enzyme-catalyzed electrochemical…

Chemical Physics · Physics 2015-09-09 Mohamed Serry , M. A. Sakr

This study proposes a novel design of glucose sensor with enhanced selectivity and sensitivity by using graphene Schottky diodes, which is composed of Graphene (G)/Platinum Oxide (PtO)/n-Silicon (Si) heterostructure. The sensor was tested…

Applied Physics · Physics 2020-01-01 Mahmoud A. Sakr , Karim Elgammal , Anna Delin , Mohamed Serry

Silicon nanochannel biological field effect transistors have been developed for glucose detection. The device is nanofabricated from a silicon-on-insulator wafer with a top-down approach and surface functionalized with glucose oxidase. The…

Biological Physics · Physics 2008-02-14 Xihua Wang , Yu Chen , Katherine A. Gibney , Shyamsunder Erramilli , Pritiraj Mohanty

An effective biosensor based on two-dimensional (2D) Co-ZIF-L nanosheets for sensitive electrochemical non-enzymatic glucose detection is developed, which exhibits high electrocalalytic activities towards glucose due to the ordered porous…

Applied Physics · Physics 2022-02-15 Nana Liu , Ningyan Cheng , Chengwu Yang , Weichang Hao , Yi Du

A novel approach for electrochemical tuning of alcohol oxidase (AOx) and alcohol dehydrogenase (ADH) biocatalysis towards butanol-1 oxidation by incorporating enzymes in various designs of amperometric biosensors is presented. The…

Chemical Physics · Physics 2021-02-01 Daria Semenova , Tiago Pinto , Marcus Koch , Krist V. Gernaey , Helena Junicke

Cell-based biosensors constitute a fundamental tool in biotechnology, and their relevance has greatly increased in recent years as a result of a surging demand for reduced animal testing and for high-throughput and cost-effective in vitro…

We developed a scalable, label-free all-electronic sensor for D-glucose based on a carbon nanotube transistor functionalized with pyrene-1-boronic acid. This sensor responds to glucose in the range 1 uM - 100 mM, which includes typical…

This review explores the synthesis, characterization, and therapeutic applications of zinc oxide nanoparticles (ZnO NPs) in the treatment of diabetes mellitus. The study delves into both chemical and green synthesis methods, comparing their…

Medical Physics · Physics 2024-09-10 Iqra Yousaf

In this paper, we present a simple yet sensitive method for glucose sensing using carbon nanotube field-effect transistor (CNTFET) based biosensor. The CNTs were well-dispersed to form CNT networks and maintain functional connectivity among…

Chemical Physics · Physics 2020-06-30 Reetu Raj Pandey , Jie Liang , Dilek Cakiroglu , Benoît Charlot , Aida Todri-Sanial

Glucose monitoring plays a critical role in managing diabetes, one of the most prevalent diseases globally. The development of fast-responsive, cost-effective, and biocompatible glucose sensors is essential for improving patient care. In…

This paper proposes a novel wireless, battery-free, and label-free biosensor for minimally invasive and non-invasive permittivity sensing for applications such as detecting glucose levels in the interstitial dermal fluid. The miniaturized,…

Applied Physics · Physics 2022-10-19 Rehab S. Hassan

Glucose oxidation is a key reaction in biosensing and energy conversion, with anodized copper electrodes showing great potential as catalysts for its enhancement. This study explores the relationship between anodization parameters and…

Continuous glucose monitoring (CGM) is vital for diabetes care, but current systems rely on invasive implants or electrochemical sensors that often cause discomfort and skin irritation. Non-invasive alternatives remain limited by low…

With the continuous development and improvement of medical services, there is a growing demand for improving diabetes diagnosis. Exhaled breath analysis, characterized by its speed, convenience, and non-invasive nature, is leading the trend…

Signal Processing · Electrical Eng. & Systems 2024-06-06 Jiaming Wei , Tong Liu , Jipeng Huang , Xiaowei Li , Yurui Qi , Gangyin Luo

This paper presents a proof-of-concept ultra-low voltage and ultra-low power chronoamperometric electrochemical sensor for non-enzymatic glucose readout integrated circuit (IC) in 130nm CMOS detection featuring a reconfigurable…

A novel nanostructured electrochemical immunsensor for the determination of progesterone is reported. The approach combines the properties of gold nanoparticles with the use of a graphite-Teflon composite electrode matrix, into which gold…

Materials Science · Physics 2007-08-13 J. -M. Pingarron , P. Yanez-Sedeno , A. Gonzalez-Cortes , V. Carralero

Biosensor data has the potential ability to improve disease control and detection. However, the analysis of these data under free-living conditions is not feasible with current statistical techniques. To address this challenge, we introduce…

Applications · Statistics 2021-03-30 Marcos Matabuena , Alexander Petersen , Juan C. Vidal , Francisco Gude

This study details the use of printing and other additive processes to fabricate a novel amperometric glucose sensor. The sensor was fabricated using a Au coated 12.7 micron polyimide film as a starting material, where micro-contact…

‹ Prev 1 2 3 10 Next ›