We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is…
We report initial results from the design and evaluation of two pixellated PIN Cadmium Zinc Telluride detectors and an ASIC-based readout system. The prototype imaging PIN detectors consist of 4X4 1.5 mm square indium anode contacts with…
Gaseous detectors are fundamental components of all present and planned high energy physics experiments. Over the past decade two representatives (GEM, Micromegas) of the Micro-Pattern Gas Detector (MPGD) concept have become increasingly…
We present the results of using standard IMARAD CZT detectors with a 100 MHz readout of the anode and cathode pulses. The detectors, 2 cm x 2 cm large and 0.5 cm thick, have 64 Indium pixellated anode contacts at a pitch of 2.5 mm. We…
Pattern formation and self-organization are phenomena commonly observed experimentally in diverse types of plasma systems, including atmospheric-pressure electric arc discharges. However, numerical simulations reproducing anode pattern…
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um…
Measuring the depth of interaction in thick Cadmium-Zinc-Telluride (CZT) detectors allows improved imaging and spectroscopy for hard X-ray imaging above 100 keV. The Energetic X-ray Imaging Survey Telescope (EXIST) will employ relatively…
The propagation and modification of hard-scattered partons in the QGP can be studied using various types of jet and jet-like correlation measurements. The STAR detector with its full azimuthal and large pseudorapidity acceptance, as well as…
The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…
The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous because of its size (around 7 cm^2 active area) and its…
Micromegas detector is a gas detector with parallel plate structure, and it consists of a conversion gap in which radiations liberate ionization electrons and a thin amplification gap. The signal of the micromegas detector consists of two…
We study the magnon spectrum of stacked zig-zag chains of point magnetic dipoles with an easy axis. The anisotropy due to the dipolar interactions and the two-point basis of the zig-zag chain unit cell combine to give rise to topologically…
We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…
We present an original design for large area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides an uniform 200…
Pattern discharge is a common mode in dielectric barrier discharge (DBD) and has broad application prospects in various industrial fields, such as material surface treatment, environmental monitoring, and biomedical applications. In this…
We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with $\mathrm{^{32}Ar}$ Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is…
We investigate the low-lying excitation spectrum and ground-state properties of narrow graphene nanoribbons with zigzag edge configurations. Nanoribbons of comparable widths have been synthesized very recently [P. Ruffieux, \emph{et al.}…
The topic of the paper is the position reconstruction from signals of segmented detectors. With the help of a simple simulation, it is shown that the position reconstruction using the centre-of-gravity method is strongly biased, if the…
In this comprehensive study, we undertake a thorough theoretical examination of the electronic subband structures within cove-edged zigzag graphene nanoribbons (CZGNRs) using the tight-binding model. These unique nanostructures arise from…