Related papers: A Comparative Study of Straight-Strip and Zigzag-I…
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in…
We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides…
We present an analytical scheme for the design of realistic metagratings for wide-angle engineered reflection. These recently proposed planar structures can reflect an incident plane wave into a prescribed (generally non-specular) angle…
Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors,…
The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself…
The Micro-Pattern Gaseous Detectors offer excellent spatial and temporal resolution in harsh radiation environments of high-luminosity colliders. In this work, an attempt has been made to establish an algorithm for estimating the time…
Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…
In this work, charge collection profiles of non-irradiated and irradiated 150 $\mu$m $p$-type pad diodes were measured using a 5.2 GeV electron beam traversing the diode parallel to the readout electrode. Four diodes were irradiated to 1…
With the aim to parallelize and monitor biological or biochemical phenomena, trapping and immobilization of objects such as particles, droplets or cells in microfluidic devices has been an intense area of research and engineering so far.…
A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The…
MicroPattern Gaseous Detectors (MPGD) made of resistive strips have raised as a promising technology for the protection against spark processes having place in the gaseous chamber. The reproduction of the signals and its propagation through…
A novel approach is presented to unfold particle hit positions in tracking detectors with multiplexed readout representing an underdetermined system of linear equations. The method does not use any prior information about the hit positions,…
We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…
The demand for a large number of readout channels has been a limiting factor for the application of Micro-pattern Gaseous Detectors (MPGDs) in achieving higher spatial resolution and larger detection areas. This challenge is further…
Micro-pattern gaseous detectors (MPGDs) are a class of technologies that enable the full three-dimensional spatial reconstruction of ionisation tracks from nuclear and electron recoils in gas. Anticipating near-future 30 m$^3$-scale time…
The conventional readout method of the RPC detector uses two sets of orthogonal readout strips placed at the both sides of the gas gap to collect signals of opposite polarities to obtain space points. A new readout method utilizing the…
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline…
This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of…
We propose a new strip configuration for CdTe X-ray detectors, named "Wide-gap CdTe strip detector", in which the gap between adjacent strips is much wider than the width of each strip. It has been known that the observed energies of an…