Related papers: High Resolution, Deep Imaging Using Confocal Time-…
Computed Tomography (CT) is widely used in healthcare for detailed imaging. However, Low-dose CT, despite reducing radiation exposure, often results in images with compromised quality due to increased noise. Traditional methods, including…
We report a computational 3D microscopy technique, termed Fourier ptychographic diffraction tomography (FPDT), that iteratively stitches together numerous variably illuminated, low-resolution images acquired with a low-numerical aperture…
Fourier ptychography microscopy (FPM), sharing its roots with synthetic aperture technique and phase retrieval method, is a recently developed computational microscopic super-resolution technique. By turning on the light-emitting diode…
In this paper, we study the mathematical imaging problem of diffraction tomography (DT), which is an inverse scattering technique used to find material properties of an object by illuminating it with probing waves and recording the…
Low-dose computed tomography (LDCT) reduces radiation exposure but suffers from image artifacts and loss of detail due to quantum and electronic noise, potentially impacting diagnostic accuracy. Transformer combined with diffusion models…
Long-distance depth imaging holds great promise for applications such as autonomous driving and robotics. Direct time-of-flight (dToF) imaging offers high-precision, long-distance depth sensing, yet demands ultra-short pulse light sources…
Dynamic optical coherence tomography (DOCT) statistically analyzes fluctuations in time-sequential OCT signals, enabling label-free and three-dimensional visualization of intratissue and intracellular activities. Current DOCT methods, such…
Direct time-of-flight (dToF) sensors are promising for next-generation on-device 3D sensing. However, limited by manufacturing capabilities in a compact module, the dToF data has a low spatial resolution (e.g., $\sim 20\times30$ for iPhone…
In recent years, computational Time-of-Flight (ToF) imaging has emerged as an exciting and a novel imaging modality that offers new and powerful interpretations of natural scenes, with applications extending to 3D, light-in-flight, and…
Many naturally-occuring models in the sciences are well-approximated by simplified models, using multiscale techniques. In such settings it is natural to ask about the relationship between inverse problems defined by the original problem…
In tomographic reconstruction, the image quality of the reconstructed images can be significantly degraded by defects in the measured two-dimensional (2D) raw image data. Despite the importance of screening defective 2D images for robust…
Time of Flight (ToF) is a prevalent depth sensing technology in the fields of robotics, medical imaging, and non-destructive testing. Yet, ToF sensing faces challenges from complex ambient conditions making an inverse modelling from the…
Confocal and multiphoton microscopy are effective techniques to obtain high-contrast images of 2-D sections within bulk tissue. However, scattering limits their application to depths only up to ~1 millimeter. Multimode fibers make excellent…
Diffuse optical imaging (DOI) offers valuable insights into scattering mediums, but the quest for high-resolution imaging often requires dense sampling strategies, leading to higher imaging errors and lengthy acquisition times. This work…
Human ability to visualize an image is usually hindered by optical scattering. Recent extensive studies have promoted imaging technique through turbid materials to a reality where color image can be restored behind scattering media in real…
Optical microscopy has so far been restricted to superficial layers, leaving many important biological questions unanswered. Random scattering causes the ballistic focus, which is conventionally used for image formation, to decay…
Fiber-form optics extends the high-resolution tomographic imaging capabilities of Optical Coherence Tomography (OCT) to the inside of the human body, i.e., endoscopic OCT. However, it still faces challenges due to the trade-off between…
Time-of-Flight non-line-of-sight (ToF NLOS) imaging techniques provide state-of-the-art reconstructions of scenes hidden around corners by inverting the optical path of indirect photons scattered by visible surfaces and measured by…
In this work, we are concerned with the diffusive optical tomography (DOT) problem in the case when only one or two pairs of Cauchy data is available. We propose a simple and efficient direct sampling method (DSM) to locate inhomogeneities…
Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the…