Related papers: Learning Rotation Invariant Features for Cryogenic…
We propose a framework to jointly determine the deformation parameters and reconstruct the unknown volume in electron cryotomography (CryoET). CryoET aims to reconstruct three-dimensional biological samples from two-dimensional projections.…
In single particle reconstruction (SPR) from cryo-electron microscopy (cryo-EM), the 3D structure of a molecule needs to be determined from its 2D projection images taken at unknown viewing directions. Zvi Kam showed already in 1980 that…
In cryo-electron microscopy (cryo-EM), a microscope generates a top view of a sample of randomly-oriented copies of a molecule. The problem of single particle reconstruction (SPR) from cryo-EM is to use the resulting set of noisy 2D…
The growing role of data-driven approaches to scientific discovery has unveiled a large class of models that involve latent transformations with a rigid algebraic constraint. Three-dimensional molecule reconstruction in Cryo-Electron…
Differentiating signals from the background in micrographs is a critical initial step for cryogenic electron microscopy (cryo-EM), yet it remains laborious due to low signal-to-noise ratio (SNR), the presence of contaminants and densely…
In this paper we study the formal algebraic structure underlying the intrinsic classification algorithm, recently introduced by Hadani, Shkolnisky, Singer and Zhao, for classifying noisy projection images of similar viewing directions in…
Electron cryo-tomography (cryo-ET) enables 3D imaging of complex, radiation-sensitive structures with molecular detail. However, image contrast from the interference of scattered electrons is nonlinear with atomic density and multiple…
Cryo-electron tomography (Cryo-ET) is a powerful tool in structural biology for 3D visualization of cells and biological systems at resolutions sufficient to identify individual proteins in situ. The measurements are collected by tilting…
Electron cryomicroscopy (cryo-EM) is a technique in structural biology used to reconstruct accurate volumetric maps of molecules. One step of the cryo-EM pipeline involves solving an inverse-problem. This inverse-problem, referred to as…
Over the past decade, cryogenic electron microscopy (cryo-EM) has emerged as a primary method for determining near-native, near-atomic resolution 3D structures of biological macromolecules. In order to meet increasing demand for cryo-EM,…
Cryo-electron microscopy (cryo-EM) is an imaging modality that provides unique insights into the dynamics of proteins and other building blocks of life. The algorithmic challenge of jointly estimating the poses, 3D structure, and…
Cellular Electron Cryo-Tomography (CECT) is a powerful 3D imaging tool for studying the native structure and organization of macromolecules inside single cells. For systematic recognition and recovery of macromolecular structures captured…
Cryogenic electron microscopy (Cryo-EM) has become an essential tool for capturing high-resolution biological structures. Despite its advantage in visualizations, the large storage size of Cryo-EM data file poses significant challenges for…
We presented a new 3D refinement method for Cryo-EM single particle analysis which can improve the resolution of final electron density map in this paper. We proposed to enforce both sparsity and smoothness to improve the regularity of…
Classifying structural variability in noisy projections of biological macromolecules is a central problem in Cryo-EM. In this work, we build on a previous method for estimating the covariance matrix of the three-dimensional structure…
Cryo-electron tomography (cryo-ET) enables 3D visualization of cellular structures. Accurate reconstruction of high-resolution volumes is complicated by the very low signal-to-noise ratio and a restricted range of sample tilts. Recent…
We show that de-focused single particle images recorded using a cryo-electron microscope (cryoEM) system may be processed like a Fresnel zone in-line hologram to obtain physically meaningful quantitative phase maps associated with…
There is a clear need for developments in characterisation techniques that provide detailed information about structure-function relationships in biology. Using electron microscopy to achieve high resolution while maintaining a broad field…
Cryo-electron tomography (cryo-ET) provides direct 3D visualization of macromolecules inside the cell, enabling analysis of their in situ morphology. This morphology can be regarded as an SE(3)-invariant, denoised volumetric representation…
Single-particle reconstruction in cryo-electron microscopy (cryo-EM) is an increasingly popular technique for determining the 3-D structure of a molecule from several noisy 2-D projections images taken at unknown viewing angles. Most…