English
Related papers

Related papers: Construction and On-site Performance of the LHAASO…

200 papers

A position sensitive Cherenkov detector was built, consisting of 64 SiPMs with an active area of 3x3 mm^2 and a pixel size of 100x100 \mu m^2. The sensitive area is increased by a light concentrator which consists of 64 pyramid-shaped…

Instrumentation and Detectors · Physics 2015-06-16 Mariana Rihl , Stefan Enrico Brunner , Lukas Gruber , Johann Marton , Ken Suzuki

The Large High Altitude Air Shower Observatory (LHAASO) project has been proposed for the survey and study of cosmic rays. In the LHAASO project, the Water Cherenkov Detector Array (WCDA) is one of major detectors for searching gamma ray…

Instrumentation and Detectors · Physics 2016-01-20 Weihao Wu , Lei Zhao , Yu Liang , Li Yu , Jianfeng Liu , Shubin Liu , Qi An

Silicon Photomultipliers (SiPMs) are single photon detectors that gained increasing interest in many applications as an alternative to photomultiplier tubes. In particular in the field of space experiments, where volume, weight and power…

Instrumentation and Detectors · Physics 2024-05-14 Stefano Merzi , Fabio Acerbi , C. Aicardi , D. Fiore , V. Goiffon , Alberto Gola , O. Marcelot , A. Materne , O. Saint-Pe

Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless {\beta}{\beta} decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of…

The First G-APD Cherenkov telescope (FACT) is the first telescope using silicon photon detectors (G-APD aka. SiPM). The use of Silicon devices promise a higher photon detection efficiency, more robustness and higher precision than…

The presented results are obtained during the first steps taken in order to develop a setup and measurement procedures which allow to compare properties of diverse kinds of silicon photomultipliers. The response to low-intensity light was…

Instrumentation and Detectors · Physics 2009-11-13 C. Bosio , S. Gentile , E. Kuznetsova , F. Meddi

The Light-only Liquid Xenon experiment (LoLX) employs a small-scale detector equipped with 96 Hamamatsu VUV4 silicon photomultipliers (SiPMs) submerged in 5 kg of liquid xenon (LXe) to perform characterization measurements of light…

We developed a modular silicon photomultiplier camera to detect Earth-skimming PeV to EeV tau neutrinos with the imaging atmospheric Cherenkov technique. We built two cameras, a 256-pixel camera with S14161-6050HS SiPMs for the Trinity…

In this paper, the development of the dual mirror Small Size Telescopes (SST) for the Cherenkov Telescope Array (CTA) is reviewed. Up to 70 SST, with a primary mirror diameter of 4 m, will be produced and installed at the CTA southern site.…

Instrumentation and Methods for Astrophysics · Physics 2019-08-17 G. Pareschi , G. Agnetta , L. A. Antonelli , D. Bastieri , G. Bellassai , M. Belluso , C. Bigongiari , S. Billotta , B. Biondo , G. Bonanno , G. Bonnoli , P. Bruno , A. Bulgarelli , R. Canestrari , M. Capalbi , P. Caraveo , A. Carosi , E. Cascone , O. Catalano , M. Cereda , P. Conconi , V. Conforti , G. Cusumano , V. De Caprio , A. De Luca , A. Di Paola , F. Di Pierro , D. Fantinel , M. Fiorini , D. Fugazza , D. Gardiol , M. Ghigo , F. Gianotti , S. Giarrusso , E. Giro , A. Grillo , D. Impiombato , S. Incorvaia , A. La Barbera , N. La Palombara , V. La Parola , G. La Rosa , L. Lessio , G. Leto , S. Lombardi , F. Lucarelli , M. C. Maccarone , G. Malaguti , G. Malaspina , V. Mangano , D. Marano , E. Martinetti , R. Millul , T. Mineo , A. MistÒ , C. Morello , G. Morlino , M. R. Panzera , G. Rodeghiero , P. Romano , F. Russo , B. Sacco , N. Sartore , J. Schwarz , A. Segreto , G. Sironi , G. Sottile , A. Stamerra , E. Strazzeri , L. Stringhetti , G. Tagliaferri , V. Testa , M. C. Timpanaro , G. Toso , G. Tosti , M. Trifoglio , P. Vallania , S. Vercellone , V. Zitelli , J. P. Amans , C. Boisson , C. Costille , J. L. Dournaux , D. Dumas , G. Fasola , O. Hervet , J. M. Huet , P. Laporte , C. Rulten , H. Sol , A. Zech , R. White , J. Hinton , D. Ross , J. Sykes , S. Ohm , J. Schmoll , P. Chadwick , T. Greenshaw , M. Daniel , G. Cotter , G. S. Varner , S. Funk , J. Vandenbroucke , L. Sapozhnikov , J. Buckley , P. Moore , D. Williams , S. Markoff , J. Vink , D. Berge , N. Hidaka , A. Okumura , H. Tajima

Single Photon Emission Computed Tomography (SPECT) scanners based on photomultiplier tubes (PMTs) are still largely employed in the clinical environment. A standard camera for full-body SPECT employs $\sim50$-100 PMTs of 4-8~cm diameter and…

Instrumentation and Detectors · Physics 2021-03-01 D. Guberman , R. Paoletti , A. Rugliancich , C. Wunderlich , A. Passeri

Future large water Cherenkov and scintillator detectors have been proposed for measurements of long baseline neutrino oscillations, proton decay, supernova and solar neutrinos. To ensure cost-effectiveness and optimize scientific reach, one…

Instrumentation and Detectors · Physics 2013-03-20 J. Brack , B. Delgado , J. Dhooghe , J. Felde , B. Gookin , S. Grullon , J. R. Klein , R. Knapik , A. LaTorre , S. Seibert , K. Shapiro , R. Svoboda , L. Ware , R. Van Berg

Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…

Instrumentation and Detectors · Physics 2020-01-29 V. Mikhaylov , F. Guber , A. Ivashkin , A. Kugler , V. Kushpil , S. Morozov , O. Svoboda , P. Tlusty

We report on the characterization of near-ultraviolet high density silicon photomultiplier (\SiPM) developed at Fondazione Bruno Kessler (\FBK) at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and…

A Compton gamma imager has been developed for use in consequence management operations and in security investigations. The imager uses solid inorganic scintillator, known for robust performance in field survey conditions. The design was…

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The…

Instrumentation and Detectors · Physics 2018-10-17 X. L. Sun , T. Tolba , G. F. Cao , P. Lv , L. J. Wen , A. Odian , F. Vachon , A. Alamre , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. S. Barbeau , D. Beck , V. Belov , T. Bhatta , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , L. Cao , W. R. Cen , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , M. Côté , A. Craycraft , W. Cree , J. Dalmasson , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , R. DeVoe , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , J. Echevers , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , S. Feyzbakhsh , P. Fierlinger , R. Fontaine , D. Fudenberg , G. Gallina , G. Giacomini , R. Gornea , G. Gratta , E. V. Hansen , D. Harris , M. Heffner , E. W. Hoppe , J. Hößl , A. House , P. Hufschmidt , M. Hughes , Y. Ito , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , X. S. Jiang , A. Karelin , L. J. Kaufman , D. Kodroff , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , G. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , M. Moe , B. Mong , D. C. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , O. Nusair , K. Odgers , M. Oriunno , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , S. Parent , A. Piepke , A. Pocar , J. -F. Pratte , D. Qiu , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retière , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , D. Sinclair , K. Skarpaas VIII , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , M. Tarka , J. Todd , T. I. Totev , R. Tsang , T. Tsang , B. Veenstra , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , M. Wagenpfeil , Q. Wang , J. Watkins , M. Weber , W. Wei , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Zeldovich , J. Zhao , Y. Zhou , T. Ziegler

The camera of the Large Size Telescopes (LSTs) of the Cherenkov Telescope Array (CTA) consists of 265 photosensor modules, each of them containing 7 photomultiplier tubes (PMTs), a slow control board (SCB), a readout board, and a trigger…

Instrumentation and Methods for Astrophysics · Physics 2015-09-07 D. Hadasch , Y. Konno , H. Kubo , D. Nakajima , H. Ohoka , T. Saito , M. Teshima , the LST Team

Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes…

Instrumentation and Detectors · Physics 2010-09-01 Gamal Ahmed , Paul Buehler , Michael Cargnelli , Roland Hohler , Johann Marton , Herbert Orth , Ken Suzuki

Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…

Instrumentation and Detectors · Physics 2017-11-17 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith