Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation…

For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good…

A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $\mu$m. Three analog pixels were…

A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast…

Instrumentation and Detectors · Physics 2018-06-08 Qiang Cao , Xin Li , Liwei Wang , Jie Kuang , Yonggang Wang , Cheng Li

Micromegas detector is considered to be a promising candidate for a large variety of high-rate experiments. Micromegas of various geometries have already been established as appropriate for these experiments for their performances in terms…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar , Sudeb Bhattacharya

The fast timing MPGD is a micro-pattern gaseous detector conceived for achieving sub-nanosecond time resolution while maintaining the ability to instrument large areas in high-rate environments; applications of such technology are…

Instrumentation and Detectors · Physics 2022-12-21 Antonello Pellecchia , Piet Verwilligen

Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas…

Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromegas chambers with 1 cm2 pad segmentation are studied for the…

A silicon 3D detector with a single cell of 50x50 um2 was produced and evaluated for timing applications. The measurements of time resolution were performed for 90Sr electrons with dedicated electronics used also for determining time…

Instrumentation and Detectors · Physics 2019-06-26 G. Kramberger , V. Cindro , D. Flores , S. Hidalgo , B. Hiti , M. Manna , I. Mandić , M. Mikuž , D. Quirion , G. Pellegrini , M. Zavrtanik

Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon…

Instrumentation and Detectors · Physics 2020-04-22 Spencer R. Klein

A monolithic silicon pixel ASIC prototype, produced in 2024 as part of the Horizon 2020 MONOLITH ERC Advanced project, was tested with a 120 GeV/c pion beam. The ASIC features a matrix of hexagonal pixels with a 100 \mu m pitch, read by…

Within the ATTRACT FASTPIX project, a monolithic pixel sensor demonstrator chip has been developed in a modified 180 nm CMOS imaging process technology, targeting sub-nanosecond timing precision for single ionising particles. It features a…

The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$…

Instrumentation and Detectors · Physics 2016-05-12 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders require the use of time information in tracking, due to the expected levels of…

Instrumentation and Detectors · Physics 2023-01-27 Gian Matteo Cossu , Adriano Lai

The paper reports on the timing resolution achieved with Low-Gain Avalanche Diodes (LGADs), optimised for extreme-fluence conditions, at the DESY Test Beam Facility using 4~GeV/c electrons. The LGADs adopt an $n$-in-$p$ technology with a…

A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant…

Instrumentation and Detectors · Physics 2015-06-11 D. Attie , A. Chaus , P. Colas , E. Ferrer , J. Galan , I. Giomatari , F. J. Iguaz , A. Gongadze , R. De Oliveira , T. Papaevangelou , A. Peyaud

The Micro-Pattern Gaseous Detectors offer excellent spatial and temporal resolution in harsh radiation environments of high-luminosity colliders. In this work, an attempt has been made to establish an algorithm for estimating the time…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sudeb Bhattacharya

A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors…

The PAMELA apparatus has been assembled and it is ready to be launched in a satellite mission to study mainly the antiparticle component of cosmic rays. In this paper the performances obtained for the silicon microstrip detectors used in…

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude,…