Related papers: Effective gain and Ion Back Flow study of triple a…
In gaseous tracking detectors with a large gaseous volume multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. We…
Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…
Gaseous detectors are used in both low energy and high energy physics experiments. The present day gaseous detectors, i.e., the Micro-Pattern gaseous detectors (MPGD) are more efficient and fast. Gas Electron multiplier (GEM) is quite well…
Gas Electron Multiplier (GEM) is one of the mostly used gaseous detectors in the High Energy Physics (HEP) experiments. GEMs are widely used as tracking devices due to their high-rate handling capability and good position resolution. An…
We study the feedback of positive ions in triple and quadruple Gas Electron Multiplier (GEM) detectors. The effects of GEM hole diameter, detector gain, applied voltages, number of GEMs and other parameters on ion feedback are investigated…
A systematic study is performed to measure the ion backflow fraction of the GEM detectors. The effects of different voltage configurations and Ar/CO_2 gas mixtures, in ratios of 70:30, 80:20 and 90:10, on positive ion fraction are…
Gas Electron Multipliers have undergone a very consistent development since their invention in 1997. Their production procedures have been tuned in such a way that nowadays it is possible to produce foils with areas of the order of the…
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed…
Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC.…
We further study the performance of single, double and triple Gas Electron Multiplier (GEM) detectors in pure noble gases at high pressures, in the range of 1-10 atm. We confirm that light noble gases, in particular He and its mixtures with…
One of the potential problems of a Micro-Pattern Gaseous Detector (MPGD)-based Time Projection Chamber (TPC) is the Ion back Flow (IBF): ions generated through the avalanche amplification process flow back to the drift volume of the TPC and…
Micro-Pattern Gas Detectors (MPGDs) represent a category of gaseous ionization detectors that utilize microelectronics. They feature a remarkably small distance between the high potential difference anode and cathode electrodes and are…
The Gas Electron Multiplier (GEM) detectors are widely used in high-energy physics (HEP) experiments as tracking devices because of their excellent position resolution and to handle high particle rates capability. Charging-up effect is a…
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…
Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…
A prototype Gas Electron Multiplier (GEM) detector is under construction for medical imaging purposes. A single thick GEM of size 10x10 cm^2 is assembled inside a square shaped air-tight box which is made of Perspex glass. In order to…
Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas…
The Gas Electron Multiplier (GEM) has become a widely used technology for high-rate particle physics experiments like COMPASS, LHCb and are being used as the readout system for the upcoming upgrade version of other experiments such as ALICE…
Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG)…
The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to simulate exactly the effective charge gain have not…