English
Related papers

Related papers: Sub-Kelvin Cooling for the BICEP Array Project

200 papers

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and…

Instrumentation and Methods for Astrophysics · Physics 2014-07-21 Shugo Oguri , Jihoon Choi , Masanori Kawai , Osamu Tajima

Next-generation gravitational wave observatories are expected to use cryogenically cooled, pendulum-suspended 200 kg test mass mirrors from a crystalline material such as crystalline silicon. During operation of the observatories, these…

We present here a study of the use of the SiAl alloy CE7 for the packaging of silicon devices at cryogenic temperatures. We report on the development of baseplates and feedhorn arrays for millimeter wave bolometric detectors for…

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read…

We present measurements of the electrical and thermal properties of new arrays of bolometeric detectors that were fabricated as part of a program to develop bolometers optimized for the low photon background of the EBEX balloon-borne…

Instrumentation and Methods for Astrophysics · Physics 2009-08-17 Johannes Hubmayr , Francois Aubin , Eric Bissonnette , Matt Dobbs , Shaul Hanany , Adrian T. Lee , Kevin MacDermid , Xiaofan Meng , Ilan Sagiv , Graeme Smecher

A novel low temperature bolometric method has been devised and implemented for high-precision measurements of the microwave surface resistance of small single-crystal platelet samples having very low absorption, as a continuous function of…

The background-limited spectral imaging of the early Universe requires spaceborne terahertz (THz) detectors with the sensitivity 2-3 orders of magnitude better than that of the state-of-the-art bolometers. To realize this sensitivity…

Other Condensed Matter · Physics 2013-03-06 Jian Wei , David Olaya , Boris Karasik , Sergey Pereverzev , Andrei Sergeev , Michael Gershenson

Much of the exotic functionality of prime interest in quantum materials emerges from structural and electronic ground states that can only be accessed at cryogenic temperatures. Understanding device operation therefore requires structural…

The aim of the SELENDIS project within the EDELWEISS collaboration is to observe single $e^- h^+$ pairs in lightweight (3.3 g) cryogenic germanium bolometers with charge and phonon readout at biases up to $\sim 100$ V. These devices are…

Instrumentation and Detectors · Physics 2022-09-07 H. Lattaud , Q. Arnaud , J. Billard , J. Colas , L. Dumoulin , M. De Jésus , A. Juillard , J. Gascon , S. Marnieros , C. Oriol

Buffer gas cooling with a $^4$He gas is used to perform laser-absorption spectroscopy of the $^{12}$C$_2$H$_2$ ($\nu_1+\nu_3$) band at cryogenic temperatures. Doppler thermometry is first carried out to extract translational temperatures…

Instrumentation and Methods for Astrophysics · Physics 2015-06-23 L. Santamaria , V. Di Sarno , I. Ricciardi , M. De Rosa , S. Mosca , G. Santambrogio , P. Maddaloni , P. De Natale

Fast feedback from cryogenic electrical characterization measurements is key for the development of scalable quantum computing technology. At room temperature, high-throughput device testing is accomplished with a probe-based solution,…

The period 1980-2000 saw the impressive development of applied superconductivity in high-energy particle accelerators, from single components to long strings of superconducting magnets and high-frequency acceleration cavities. Large and…

Accelerator Physics · Physics 2026-02-17 Philippe Lebrun

A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…

Applied Physics · Physics 2020-08-26 Joris Vincent van Heijningen

Millimeter-wave refracting telescopes targeting the degree-scale structure of the cosmic microwave background (CMB) have recently grown to diffraction-limited apertures of over 0.5 meters. These instruments are entirely housed in vacuum…

We report the successful operation of a functional pixel detector with gaseous helium cooling. Using an accurate mock-up beforehand, the cooling was validated. We use a miniature turbo compressor to propel the helium at $2\,g/s$ under…

Instrumentation and Detectors · Physics 2023-06-28 Thomas Theodor Rudzki , Frank Meier Aeschbacher , Marin Deflorin , Niculin Flucher

In order to allow a good separation of isotopes in a High Resolution Mass Spectrometer (HRMS), the transverse emittance and the energy spread of the beam should have very low values, for this reason a Beam Cooler (BC) is planned to be…

Accelerator Physics · Physics 2023-10-05 A. Ruzzon , M. Maggiore , C. Roncolato , G. Ban , J. F. Cam , C. Gautier , C. Vandamme

In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1\,eV. Even with outstanding performances in both energy…

The Simons Observatory aims to field 70,000 Transition-Edge Sensor (TES) bolometers to measure the Cosmic Microwave Background. With so many detectors, rapid but accurate validation of their properties prior to their integration into…

Instrumentation and Detectors · Physics 2023-06-21 Rita F. Sonka , Shannon M. Duff , Daniel Dutcher , Suzanne T. Staggs

Cryogenic CMOS technology (cryo-CMOS) offers a scalable solution for quantum device interface fabrication. Several previous works have studied the characterization of CMOS technology at cryogenic temperatures for various process nodes.…

Applied Physics · Physics 2019-02-20 Chao Luo , Zhen Li , TengTeng Lu , Jun Xu , GuoPing Guo
‹ Prev 1 4 5 6 7 8 10 Next ›