English
Related papers

Related papers: A GEM based TPC for beam monitoring

200 papers

Gas electron multipliers (GEM) detectors are gaseous detectors widely used for tracking and imaging applications due to their good position resolution, high efficiency at high irradiation rates, among other factors. In the present work,…

Instrumentation and Detectors · Physics 2023-03-13 Vishal Kumar , Subhendu Das , Promita Roy , Purba Bhattacharyab , Supratik Mukhopadhyay , Nayana Majumdar , Sandip Sarkar

The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…

Instrumentation and Detectors · Physics 2011-10-20 J. Yu , E. Baldelomar , K. Park , S. Park , M. Sosebee , N. Tran , A. P. White

For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. To achieve the required point resolution, Micro-Pattern Gaseous…

Instrumentation and Detectors · Physics 2020-06-26 Ties Behnke , Ralf Diener , Ulrich Einhaus , Uwe Krämer , Paul Malek , Oliver Schäfer , Mengqing Wu

We describe a concept for a NASA SMEX Mission in which Gas Electron Multiplier (GEM) detectors, developed at CERN, are adapted for use in X-ray astronomy. These detectors can be used to obtain moderately large detector area and…

The gain measurements of several 1 mm-thick, 10$\times$10 cm$^2$ Thick Gaseous Electron Multipliers (ThGEMs), operated in pure argon at 3.3 bar and room temperature are presented. Electrostatic simulations, performed with the COMSOL…

Instrumentation and Detectors · Physics 2025-10-07 G. Eurin , A. Delbart , R. De Oliveira , A. Drozd , P. Granger , M. Karolak , B. Mehl

For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM…

The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for…

Instrumentation and Detectors · Physics 2008-12-18 Raz Alon , Marco Cortesi , Amos Breskin , Rachel Chechik

Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…

Instrumentation and Detectors · Physics 2008-11-26 A. Bondar , A. Buzulutskov , R. de Oliveira , L. Ropelewski , F. Sauli , L. Shekhtman

Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of $\mu$m were measured on the GEM plane along with…

The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different…

We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC…

The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical…

Instrumentation and Detectors · Physics 2012-03-20 Serge Duarte Pinto , Rhodri Jones , Leszek Ropelewski , Jens Spanggaard , Gerard Tranquille

Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The high rate handling capability and spatial resolution make it a…

Instrumentation and Detectors · Physics 2023-05-17 S. Chatterjee , A. Sen , R. Paul , S. Sahai , S. Das , S. Biswas

The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate…

Instrumentation and Detectors · Physics 2015-10-28 Kiadtisak Saenboonruang , Piyakul Kumphiranon , Kittipong Kulasri , Anawat Ritthirong

The Large Electron Multipliers (LEMs) are key components of double phase liquid argon TPCs. The drifting charges after being extracted from the liquid are amplified in the LEM positioned half a centimeter above the liquid in pure argon…

Instrumentation and Detectors · Physics 2015-06-23 C. Cantini , L. Epprecht , A. Gendotti , S. Horikawa , L. Periale , S. Murphy , G. Natterer , C. Regenfus , F. Resnati , F. Sergiampietri , A. Rubbia , T. Viant , S. Wu

Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and…

Instrumentation and Detectors · Physics 2018-08-15 Rajendra Nath Patra , Rama N. Singaraju , Saikat Biswas , Zubayer Ahammed , Tapan K. Nayak , Yogendra P. Viyogi

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3$\times$1$\times$1~m$^3$) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of…

Instrumentation and Detectors · Physics 2021-04-19 WA105 collaboration

For the International Large Detector (ILD), foreseen to be built at the International Linear Collider (ILC), a Time Projection Chamber (TPC) is intended to be used as the main tracking detector. The amplification will be provided by Micro…

Instrumentation and Detectors · Physics 2017-03-17 Paul Malek

We present work on the detection of neutral particles via nuclear recoils in gas-filled Time Projection Chambers (TPCs). We employ Gas Electron Multipliers (GEMs) to amplify the signal and silicon pixel electronics to detect the avalanche…

A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a…