English
Related papers

Related papers: The long duration cryogenic system of the OLIMPO b…

200 papers

We have developed low temperature part of an ultra high vacuum scanning probe microscope (UHV-SPM) working at variable temperature within the range from 20 K to 700 K. To achieve the required temperature range, a flow cooling system using…

Instrumentation and Detectors · Physics 2016-10-04 Jiri Frolec , Jakub Vonka , Pavel Hanzelka , Tomas Kralik , Vera Musilova , Pavel Urban

Among the global efforts to directly detect dark matter, the only positive claim so far relies on NaI(Tl) crystal detectors, making this technology of particular interest. ASTAROTH is a project aimed at developing the next generation of…

Instrumentation and Detectors · Physics 2026-02-09 F. Alessandria , F. B. Armani , S. Coelli , D. Cortis , D. D'Angelo , E. Martinenghi , M. Monti , D. Orlandi , M. Sorbi , V. Toso , A. Zani

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic…

Instrumentation and Methods for Astrophysics · Physics 2022-04-27 S. Masi , E. S. Battistelli , P. de Bernardis , C. Chapron , F. Columbro , G. D'Alessandro , M. De Petris , L. Grandsire , J. -Ch. Hamilton , S. Marnieros , L. Mele , A. May , A. Mennella , C. O'Sullivan , A. Paiella , F. Piacentini , M. Piat , L. Piccirillo , G. Presta , A. Schillaci , A. Tartari , J. -P. Thermeau , S. A. Torchinsky , F. Voisin , M. Zannoni , P. Ade , J. G. Alberro , A. Almela , G. Amico , L. H. Arnaldi , D. Auguste , J. Aumont , S. Azzoni , S. Banfi , B. Bélier , A. Baù , D. Bennett , L. Bergé , J. -Ph. Bernard , M. Bersanelli , M. -A. Bigot-Sazy , J. Bonaparte , J. Bonis , E. Bunn , D. Burke , D. Buzi , F. Cavaliere , P. Chanial , R. Charlassier , A. C. Cobos Cerutti , A. Coppolecchia , G. De Gasperis , M. De Leo , S. Dheilly , C. Duca , L. Dumoulin , A. Etchegoyen , A. Fasciszewski , L. P. Ferreyro , D. Fracchia , C. Franceschet , M. M. Gamboa Lerena , K. M. Ganga , B. García , M. E. García Redondo , M. Gaspard , D. Gayer , M. Gervasi , M. Giard , V. Gilles , Y. Giraud-Heraud , M. Gómez Berisso , M. González , M. Gradziel , M. R. Hampel , D. Harari , S. Henrot-Versillé , F. Incardona , E. Jules , J. Kaplan , C. Kristukat , L. Lamagna , S. Loucatos , T. Louis , B. Maffei , W. Marty , A. Mattei , M. McCulloch , D. Melo , L. Montier , L. Mousset , L. M. Mundo , J. A. Murphy , J. D. Murphy , F. Nati , E. Olivieri , C. Oriol , F. Pajot , A. Passerini , H. Pastoriza , A. Pelosi , C. Perbost , M. Perciballi , F. Pezzotta , G. Pisano , M. Platino , G. Polenta , D. Prêle , R. Puddu , D. Rambaud , E. Rasztocky , P. Ringegni , G. E. Romero , J. M. Salum , C. G. Scóccola , S. Scully , S. Spinelli , G. Stankowiak , M. Stolpovskiy , A. D. Supanitsky , P. Timbie , M. Tomasi , G. Tucker , C. Tucker , D. Viganò , N. Vittorio , F. Wicek , M. Wright , A. Zullo

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and…

Instrumentation and Methods for Astrophysics · Physics 2014-07-21 Shugo Oguri , Jihoon Choi , Masanori Kawai , Osamu Tajima

The BLAST Observatory is a proposed superpressure balloon-borne polarimeter designed for a future ultra-long duration balloon campaign from Wanaka, New Zealand. To maximize scientific output while staying within the stringent superpressure…

The Simons Observatory (SO) will provide precision polarimetry of the cosmic microwave background (CMB) using a series of telescopes which will cover angular scales from arc-minutes to tens of degrees, contain over 60,000 detectors, and…

We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint…

Instrumentation and Methods for Astrophysics · Physics 2014-08-19 S. Oguri , H. Ishitsuka , J. Choi , M. Kawai , O. Tajima

We describe the flight performance of the cryogenic system of the infrared astronomical satellite AKARI, which was successfully launched on 2006 February 21 (UT). AKARI carries a 68.5 cm telescope together with two focal plane instruments,…

We report on the performance of lumped--elements Kinetic Inductance Detector (KID) arrays for mm and sub--mm wavelengths, operated at 0.3K during the stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find that the…

A novel, to the best of our knowledge, ultralow-temperature luminescence thermometry strategy is proposed, based on a measurement of relative intensities of hyperfine components in the spectra of Ho$^{3+}$ ions doped into a crystal. A…

Optics · Physics 2025-11-25 Marina N. Popova , Mosab Diab , Boris Z. Malkin

We present a novel cooling method that uses the phase separation and evaporative cooling of 3He to reach and continuously maintain sub-kelvin temperatures. While less complex than a dilution refrigerator, the system performs similarly to a…

Other Condensed Matter · Physics 2025-03-17 P. H. Kim , M. Hirschel , J. Suranyi , J. P. Davis

The Subarcsecond Telescope And BaLloon Experiment, STABLE, is the fine stage of a guidance system for a high-altitude ballooning platform designed to demonstrate subarcsecond pointing stability, over one minute using relatively dim guide…

Instrumentation and Methods for Astrophysics · Physics 2017-02-15 Michael Borden , Derek Lewis , Hared Ochoa , Laura Jones-Wilson , Sara Susca , Michael Porter , Richard Massey , Paul Clark , Barth Netterfield

We describe a helium source cell for use in cryogenic experiments that is hermetically sealed $in$ $situ$ on the cold plate of a cryostat. The source cell is filled with helium gas at room temperature and subsequently sealed using a cold…

Instrumentation and Detectors · Physics 2023-11-06 K. E. Castoria , H. Byeon , J. Theis , N. R. Beysengulov , E. O. Glen , G. Koolstra , M. Sammon , S. A. Lyon , J. Pollanen , D. G. Rees

A new opportunity for astronomy, cosmology, physics, and atmospheric observations is the possibility to fly stratospheric payloads at 30 - 40 km of altitude during the polar night. The absence of solar irradiation for long periods, and the…

The last years have seen the first cryogenic detectors to be proposed for usage on balloon-borne missions. In such missions, the instrument will be exposed to the high radiation environment of the upper atmosphere. This radiation can induce…

Instrumentation and Detectors · Physics 2025-10-23 Merlin Kole , Kasun Wimalasena , Richard Gorby , Torsten Diesel , Zachary Greenberg , Fabian Kislat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This…

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221 Two continuous closed-cycle hydrogen Joule-Thomson (J-T) sorption coolers have been fabricated and assembled…

Instrumentation and Methods for Astrophysics · Physics 2010-01-27 G. Morgante , D. Pearson , F. Melot , P. Stassi , L. Terenzi , P. Wilson , B. Hernandez , L. Wade , A. Gregorio , M. Bersanelli , C. Butler , N. Mandolesi

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses…

We report on the development of a versatile cryogen-free laboratory cryostat based upon a commercial pulse tube cryocooler. It provides enough cooling power for continuous recondensation of circulating $^4$He gas at a condensation pressure…

Instrumentation and Detectors · Physics 2017-10-11 F. M. Piegsa , B. van den Brandt , K. Kirch

A system providing an optical frequency with an instability comparable to that of a hydrogen maser is presented. It consists of a $5$ $\mathrm{cm}$ long, vertically oriented silicon optical resonator operated at temperatures between $1.5$…

Instrumentation and Detectors · Physics 2020-04-23 Eugen Wiens , Chang Jian Kwong , Timo Müller , Stephan Schiller